Summation law for supraharmonic currents (2-150 kHz) in low-voltage installations

被引:36
|
作者
Espin-Delgado, Angela [1 ]
Ronnberg, Sarah [1 ]
Busatto, Tatiano [1 ]
Ravindran, Vineetha [1 ]
Bollen, Math [1 ]
机构
[1] Lulea Univ Technol, Elect Power Engn Grp, Lulea, Sweden
关键词
Supraharmonics; High-frequency distortion; Summation; Power quality; DISTORTION;
D O I
10.1016/j.epsr.2020.106325
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development of methods to study the propagation of supraharmonics in LV and even MV grids is a current research topic among the power quality community, which has been motivated by the efforts to establish limits for non-intentional supraharmonic emissions and planning levels. The assessment of how much distortion a bulk use of power electronics devices can inject into the grid is necessary before stating emission limits and planning levels for supraharmonics. To address this issue, the development of suitable models that can predict the supraharmonic emission from a low-voltage installation as a whole is required. This article presents a comparison of models for the summation of supraharmonics. An improved model for the summation of supraharmonics is proposed, which is validated experimentally. It is shown that by using the proposed model, predictions of supraharmonic propagation can be accomplished. Furthermore, it is demonstrated experimentally that, with the increasing number of supraharmonic emitting devices, the supraharmonic current distortion injected into a grid by an installation increases up to a maximum value and then decreases due to the capacitive nature of power electronics appliances existing in low-voltage networks.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Summation of supraharmonic currents (2-150 kHz) from EV fast charging stations
    Slangen, Tim
    Cuk, Vladimir
    Cobben, Sjef
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 220
  • [2] Measurements of High-Frequency (2-150 kHz) Distortion in Low-Voltage Networks
    Larsson, E. O. Anders
    Bollen, Math H. J.
    Wahlberg, Mats G.
    Lundmark, C. Martin
    Ronnberg, Sarah K.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1749 - 1757
  • [3] Measurement of Supraharmonic Emissions (2-150 kHz) in Real Grid Scenarios
    Amaripadath, D.
    Roche, R.
    Joseph-Auguste, L.
    Istrate, D.
    Fortune, D.
    Braun, J. P.
    Gao, F.
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [4] Impact of short-time fourier transform parameters on the accuracy of EMI spectra estimates in the 2-150 kHz supraharmonic interval
    Sandrolini, Leonardo
    Mariscotti, Andrea
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 195
  • [5] A New Measurement Method for Supraharmonics in 2-150 kHz
    Zhuang, Shuangyong
    Zhao, Wei
    Wang, Qing
    Huang, Songling
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [6] Variations in Supraharmonic Emission (2-150 kHz) of an EV Fast Charging Station under Different Supply- and Operating Conditions
    Slangen, T. M. H.
    Cuk, V.
    Cobben, J. F. G.
    de Jong, E. C. W.
    2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM, 2023,
  • [7] Impact of short-time fourier transform parameters on the accuracy of EMI spectra estimates in the 2-150 kHz supraharmonic interval
    Sandrolini, Leonardo
    Mariscotti, Andrea
    Electric Power Systems Research, 2021, 195
  • [8] A Digital Heterodyne 2-150 kHz Measurement Method
    Wright, P. S.
    Ritzmann, D.
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [9] Interaction of some low power LED lamps within 2-150 kHz (Supraharmonics)
    Agudelo-Martinez, Daniel
    Rios, Fabian
    Pavas, Andres
    2018 18TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2018,
  • [10] Conducted mains test method in 2-150 kHz band
    Coenen, Mart
    van Roermund, Arthur
    2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2014, : 601 - 604