Cerebral Oxygenation in Traumatic Brain Injury: Can a Non-Invasive Frequency Domain Near-Infrared Spectroscopy Device Detect Changes in Brain Tissue Oxygen Tension as Well as the Established Invasive Monitor?

被引:28
|
作者
Davies, David James [1 ]
Clancy, Michael [1 ]
Dehghani, Hamid [2 ]
Lucas, Samuel John Edwin [3 ]
Forcione, Mario [1 ]
Yakoub, Kamal Makram [1 ]
Belli, Antonio [1 ]
机构
[1] Univ Hosp Birmingham NHS Fdn Trust, Natl Inst Hlth Res, Surg Reconstruct & Microbiol Res Ctr, Birmingham, W Midlands, England
[2] Univ Birmingham, Sch Comp Sci, Birmingham, W Midlands, England
[3] Univ Birmingham, Sch Sport Exercise & Rehabil Sci, Birmingham, W Midlands, England
基金
欧盟地平线“2020”;
关键词
brain tissue oxygen tension; cerebral hypoxia; cerebral non-invasive monitoring; critical care; frequency domain near-infrared spectroscopy; traumatic brain injury; PRESSURE;
D O I
10.1089/neu.2018.5667
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The cost and highly invasive nature of brain monitoring modality in traumatic brain injury patients currently restrict its utility to specialist neurological intensive care settings. We aim to test the abilities of a frequency domain near-infrared spectroscopy (FD-NIRS) device in predicting changes in invasively measured brain tissue oxygen tension. Individuals admitted to a United Kingdom specialist major trauma center were contemporaneously monitored with an FD-NIRS device and invasively measured brain tissue oxygen tension probe. Area under the curve receiver operating characteristic (AUROC) statistical analysis was utilized to assess the predictive power of FD-NIRS in detecting both moderate and severe hypoxia (20 and 10mm Hg, respectively) as measured invasively. Sixteen individuals were prospectively recruited to the investigation. Severe hypoxic episodes were detected in nine of these individuals, with the NIRS demonstrating a broad range of predictive abilities (AUROC 0.68-0.88) from relatively poor to good. Moderate hypoxic episodes were detected in seven individuals with similar predictive performance (AUROC 0.576-0.905). A variable performance in the predictive powers of this FD-NIRS device to detect changes in brain tissue oxygen was demonstrated. Consequently, this enhanced NIRS technology has not demonstrated sufficient ability to replace the established invasive measurement.
引用
收藏
页码:1175 / 1183
页数:9
相关论文
共 39 条
  • [21] Non-invasive transcranial electrical brain stimulation guided by functional near-infrared spectroscopy for targeted neuromodulation: a review
    Hong, Keum-Shik
    Khan, M. N. Afzal
    Ghafoor, Usman
    JOURNAL OF NEURAL ENGINEERING, 2022, 19 (04)
  • [22] Continuous measurements of respiratory muscle blood flow and oxygen consumption using non-invasive frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy
    Rodrigues, Antenor
    Shingai, Kazuya
    Gomez, Carlos A.
    Rassam, Peter
    Rozenberg, Dmitry
    Goligher, Ewan
    Brochard, Laurent
    Roblyer, Darren
    Reid, W. Darlene
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [23] Evaluation and Diagnosis of Brain Death: a Non-Invasive Pilot Study Using Functional Near-Infrared Spectroscopy (fNIRS)
    Arabkoohi, Abolfazl
    Setarehdan, Seyed Kamaledin
    Beigee, Farahnaz Sadegh
    Jahangirifard, Alireza
    2020 28TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2020, : 119 - 123
  • [24] Non-invasive Detection of Persistent Cortical Hypoxia in Multiple Sclerosis Using Frequency Domain Near-Infrared Spectroscopy (fdNIRS)
    Adingupu, Damilola D.
    Evans, T.
    Soroush, A.
    Jarvis, S.
    Brown, L.
    Dunn, J. F.
    OXYGEN TRANSPORT TO TISSUE XLIII, 2022, 1395 : 89 - 93
  • [25] Hemodynamics of the sternocleidomastoid measured with frequency domain near-infrared spectroscopy towards non-invasive monitoring during mechanical ventilation
    Istfan, Raeef
    Gomez, Carlos A.
    Applegate, Matthew
    Rozenberg, Dmitry
    Reid, W. Darlene
    Roblyer, Darren
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (07) : 4147 - 4162
  • [26] Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument
    Hueber, DM
    Franceschini, MA
    Ma, HY
    Zhang, Q
    Ballesteros, JR
    Fantini, S
    Wallace, D
    Ntziachristos, V
    Chance, B
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01): : 41 - 62
  • [27] Non-invasive detection and quantification of brain microvascular deficits by near-infrared spectroscopy in a rat model of Vascular Cognitive Impairment
    Hallacoglu, Bertan
    Sassaroli, Angelo
    Rosenberg, Irwin H.
    Troen, Aron M.
    Fantini, Sergio
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896
  • [28] NEAR-INFRARED SPECTROPHOTOMETRY - A NON-INVASIVE METHOD FOR ASSESSING THE EFFECTS OF CHANGES IN INTRACRANIAL-PRESSURE ON BRAIN METABOLISM IN CATS
    CAIRNS, CB
    FILLIPO, D
    PROCTOR, HJ
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1984, 176 (02): : 213 - 213
  • [29] Near-infrared Spectroscopy (NIRS):: A non-invasive in vivo methodology for analysis of brain vascular and metabolic activities in real time in rodents
    Crespi, Francesco
    CURRENT VASCULAR PHARMACOLOGY, 2007, 5 (04) : 305 - 321
  • [30] Design of non-invasive brain-machine interface using near-infrared spectroscopy (brain activation response during center of gravity movement trials)
    Hou, Lei
    Watanuki, Keiichi
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2011, 77 (783): : 3962 - 3967