Objectives To evaluate the effects of different types of restorations on observer ability to detect proximal caries in CBCT images. Materials and methods Forty human premolars and molars with artificial proximal caries were placed proximal and distal to 5 molars having different restorations (amalgam, composite, resin-modified glass ionomer cement (RMGIC) fillings, zirconia, and lithium disilicate crowns) and a non-restored molar. CBCT scans were obtained using i-CAT((R) )Next Generation. Images were rated twice by 2 observers. The exact depth of artificial caries was histologically established. Sensitivity, specificity, and area under the receiver operating characteristic curve (Az) values were calculated. Results Caries detection in teeth surfaces mesial and distal to amalgam showed compromised specificity and accuracy. Moreover, caries detection in teeth surfaces mesial to zirconia crown showed low sensitivity, specificity, and accuracy. Capability of CBCT in detection of proximal caries in teeth adjacent to composite, RMGIC, and lithium disilicate was comparable to those adjacent to non-restored molar. Conclusions CBCT scans performed for tasks other than caries detection should be assessed for proximal caries in absence of any restorations as well as in presence of composite, RMGIC fillings, and lithium disilicate crowns. However, CBCT should not be used for proximal caries detection in teeth adjacent to amalgam and teeth surfaces mesial to zirconia crowns. Clinical significance It is important to investigate the influence of artifacts produced by various restorations on CBCT-based caries detection to optimize CBCT benefits, caries diagnosis and avoid unnecessary treatment of sound surfaces.
引用
收藏
页码:2413 / 2420
页数:8
相关论文
共 32 条
[1]  
3M ESPE, 2011, FILT Z550 NAN HYBR U
[2]   Intraoral versus extraoral bitewing radiography in detection of enamel proximal caries: an ex vivo study [J].
Abu El-Ela, Walaa Hussein ;
Farid, Mary Medhat ;
Mostafa, Mostafa Saad El-Din .
DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (04)
[3]   Is it possible to diagnose caries under fixed partial dentures with cone beam computed tomography? [J].
Aglarci, Osman Sami ;
Bilgin, Mehmet Selim ;
Erdem, Ali ;
Ertas, Elif Tarim .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 119 (05) :579-583
[4]  
Bader J D, 2001, J Dent Educ, V65, P960
[5]   Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT [J].
Baltacioglu, Ismail H. ;
Eren, Hakan ;
Yavuz, Yasemin ;
Kamburoglu, Kivanc .
DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (06)
[6]   Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization [J].
Belem, M. D. F. ;
Tabchoury, C. P. M. ;
Ferreira-Santos, R. I. ;
Groppo, F. C. ;
Haiter-Neto, F. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
[7]   The effects of different restorative materials on the detection of approximal caries in cone-beam computed tomography scans with and without metal artifact reduction mode [J].
Cebe, Fatma ;
Aktan, Ali Murat ;
Ozsevik, Abdul Semih ;
Ciftci, Mehmet Ertugrul ;
Surmelioglu, Hatice Derya .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 123 (03) :392-400
[8]   Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries [J].
Charuakkra, Arnon ;
Prapayasatok, Sangsom ;
Janhom, Apirum ;
Pongsiriwet, Surawut ;
Verochana, Karune ;
Mahasantipiya, Phattaranant .
IMAGING SCIENCE IN DENTISTRY, 2011, 41 (04) :143-150
[9]   Beam hardening artefacts occur in dental implant scans with the NewTom® cone beam CT but not with the dental 4-row multidetector CT [J].
Draenert, F. G. ;
Coppenrath, E. ;
Herzog, P. ;
Muller, S. ;
Mueller-Lisse, U. G. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (04) :198-203
[10]   Comparative Radiopacity of Six Flowable Resin Composites [J].
Ergucu, Z. ;
Turkun, L. S. ;
Onem, E. ;
Guneri, P. .
OPERATIVE DENTISTRY, 2010, 35 (04) :436-440