Reconstruction methods and completeness conditions for two Compton data models

被引:57
作者
Smith, B [1 ]
机构
[1] Univ Texas, Dept Elect Engn, San Antonio, TX 78249 USA
关键词
D O I
10.1364/JOSAA.22.000445
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Two different models are proposed for the data produced in a Compton imaging device. A sequence of equations, which relate the model to the distribution of radioactivity that is being imaged, is developed for each of the two models. No series expansions are used in these developments. On the basis of these sequences of equations, a completeness condition is developed for each of the two models. These completeness conditions may prove useful in the future in determining appropriate shapes, configurations, and motions of the device's detectors. A computer simulation is performed to verify one of these sequences of equations. A computer simulation is also performed to demonstrate that this sequence of equations can produce more accurate images than a backprojection reconstruction method. In addition, a procedure is proposed that could mitigate the effects of the Mein-Nishina distribution, the Doppler broadening, and the variability in the data due to the random generation of photons. (C) 2005 Optical Society of America.
引用
收藏
页码:445 / 459
页数:15
相关论文
共 47 条
[31]  
Natterer F., 1986, The Mathematics of Computerized Tomography
[32]  
ORDONEZ CE, 1997, NUCL SCI S 1997 IEEE, V2, P1361
[33]   NUMERICAL STUDY OF MULTIGRID IMPLEMENTATIONS OF SOME ITERATIVE IMAGE-RECONSTRUCTION ALGORITHMS [J].
PAN, TS ;
YAGLE, AE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) :572-588
[34]   Reconstruction of cone-beam projections from Compton scattered data [J].
Parra, LC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1543-1550
[35]  
PHILLIPS GW, 1996, NUCL SCI S 1996, V1, P362
[36]   A MULTIGRID EXPECTATION MAXIMIZATION RECONSTRUCTION ALGORITHM FOR POSITRON EMISSION TOMOGRAPHY [J].
RANGANATH, MV ;
DHAWAN, AP ;
MULLANI, N .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :273-278
[37]   An energy-subtraction Compton scatter camera design for in vivo medical imaging of radiopharmaceuticals [J].
Rohe, RC ;
Valentine, JD .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) :3256-3263
[38]   3D image reconstruction for a Compton SPECT camera model [J].
Sauve, AC ;
Hero, AO ;
Rogers, WL ;
Wilderman, SJ ;
Clinthorne, NH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) :2075-2084
[39]  
Shepp L A, 1982, IEEE Trans Med Imaging, V1, P113, DOI 10.1109/TMI.1982.4307558
[40]   CONE-BEAM TOMOGRAPHY - RECENT ADVANCES AND A TUTORIAL REVIEW [J].
SMITH, BD .
OPTICAL ENGINEERING, 1990, 29 (05) :524-534