Low-density solvent based ultrasound-assisted emulsification microextraction and on-column derivatization combined with gas chromatography-mass spectrometry for the determination of carbamate pesticides in environmental water samples

被引:45
作者
Guo, Liang [1 ]
Lee, Hian Kee [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
基金
新加坡国家研究基金会;
关键词
Low-density solvent; Ultrasound-assisted emulsification microextraction; Carbamate pesticides; On-column derivatization; LIQUID-LIQUID MICROEXTRACTION; SOLID-PHASE EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; N-METHYLCARBAMATE PESTICIDES; SUPERCRITICAL-FLUID EXTRACTION; ORGANOPHOSPHORUS PESTICIDES; SENSITIVE DETERMINATION; TRACE LEVELS; RESIDUES; IONIZATION;
D O I
10.1016/j.chroma.2012.02.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fast and efficient method for the determination of trace level of carbamate pesticides using a lower-density-than-water solvent for ultrasound-assisted emulsification microextraction coupled to on-column derivatization and analysis by GC-MS has been developed and studied. In this approach, a soft plastic Pasteur pipette was employed as a convenient extraction device. Fifty microliters of extraction solvent, of lower density than water, was injected into the sample solution held in the pipette. The latter was immediately immersed in an ultrasound water bath to form an emulsion. After 2 min extraction, the emulsion was fractionated into two layers by centrifugation. The upper layer (organic extract) could be collected conveniently by squeezing the bulb of the pipette, now held upside down, to move it into the narrow stem of the device, facilitating its retrieval for analysis. The extract was then combined with trimethylphenylammonium hydroxide and directly injected into a gas chromatography-mass spectrometry (GC-MS) system for on-column derivatization and analysis. The on-column derivatization provided an added convenience (since a separate step was not necessary). Parameters affecting the derivatization and extraction were investigated. Under the most favorable conditions, the method demonstrated high extraction efficiency with low limits of detection of between 0.01 and 0.1 mu g/L, good linearity in the range of 0.05-50 mu g/L, to 0.5-100 mu g/L, and good repeatability (RSD below 9.2%, n = 5). The proposed method was evaluated by determining carbamate pesticides in river water samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 59 条
[11]   Dispersive liquid-liquid microextraction using extraction solvent lighter than water [J].
Farajzadeh, Mir Ali ;
Seyedi, Seyed Esmaeil ;
Shalamzari, Mohammad Safi ;
Bamorowat, Mehdi .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (18) :3191-3200
[12]   Simple approach based on ultrasound-assisted emulsification-microextraction for determination of polibrominated flame retardants in water samples by gas chromatography-mass spectrometry [J].
Fontana, Ariel R. ;
Wuilloud, RodolfoG. ;
Martinez, Luis D. ;
Altamirano, Jorgelina C. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (01) :147-153
[13]   Application of dispersive liquid-liquid microextraction for the analysis of triazophos and carbaryl pesticides in water and fruit juice samples [J].
Fu, Lingyan ;
Liu, Xiujuan ;
Hu, Jia ;
Zhao, Xinna ;
Wang, Huili ;
Wang, Xuedong .
ANALYTICA CHIMICA ACTA, 2009, 632 (02) :289-295
[14]   Determination of pesticides in seaweeds by pressurized liquid extraction and programmed temperature vaporization-based large volume injection-gas chromatography-tandem mass spectrometry [J].
Garcia-Rodriguez, D. ;
Carro-Diaz, A. M. ;
Lorenzo-Ferreira, R. A. ;
Cela-Torrijos, R. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (17) :2940-2949
[15]   The high throughput analysis of N-methyl carbamate pesticides in fruits and vegetables by liquid chromatography electrospray ionization tandem mass spectrometry using a short column [J].
Goto, T ;
Ito, Y ;
Yamada, S ;
Matsumoto, H ;
Oka, H ;
Nagase, H .
ANALYTICA CHIMICA ACTA, 2006, 555 (02) :225-232
[16]   In-tube solid-phase microextraction coupled to capillary LC for carbamate analysis in water samples [J].
Gou, YN ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2774-2779
[17]   Low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction for the fast determination of trace levels of sixteen priority polycyclic aromatic hydrocarbons in environmental water samples [J].
Guo, Liang ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (31) :5040-5046
[18]   Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of three carbamate pesticides in water samples [J].
He, Lijun ;
Wang, Chunjian ;
Sun, Yinjuan ;
Luo, Xianli ;
Zhang, Jing ;
Lu, Kui .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (06) :439-448
[19]   Ultrasound-assisted dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-fluorescence detection for sensitive determination of biogenic amines in rice wine samples [J].
Huang, Ke-Jing ;
Wei, Cai-Yun ;
Liu, Wei-Li ;
Xie, Wan-Zhen ;
Zhang, Jun-Feng ;
Wang, Wei .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (38) :6636-6641
[20]   Barrier film protected, and mixed solvent optimized micro-scale membrane extraction of methyl carbamate pesticides [J].
Hylton, Kamilah ;
Mitra, Somenath .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) :60-65