Emulsification of Silicone Oil and Eye Movements

被引:42
作者
Chan, Yau Kei [1 ]
Ng, Chiu On [2 ]
Knox, Paul C. [3 ]
Garvey, Michael J. [4 ]
Williams, Rachel L. [3 ]
Wong, David [1 ,3 ]
机构
[1] Univ Hong Kong, Li Ka Shing Fac Med, Inst Eye, Pokfulam, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Mech Engn, Pokfulam, Hong Kong, Peoples R China
[3] Univ Liverpool, Dept Eye & Vis Sci, Liverpool L69 3BX, Merseyside, England
[4] Univ Liverpool, Dept Phys, Liverpool L69 3BX, Merseyside, England
关键词
ANTERIOR-CHAMBER; TAMPONADE AGENTS; VISCOSITY; EFFICIENCY; SURGERY; SIGNAL; MODEL;
D O I
10.1167/iovs.11-8586
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Emulsification is an inherent problem of silicone oil used in vitreoretinal surgery. It has been shown that silicone oil can be made more resistant to emulsification and easier to inject by adding high-molecular-weight components (5% or 10% 423-kDa polydimethylsiloxane [PDMS]) to normal 1000 mPa . s silicone oil. The authors hypothesize that this might also reduce the movement of oil within an eye. METHODS. A model eye chamber made of surface-modified poly(methyl methacrylate) was driven by a computer and a stepper motor to mimic saccadic eye movement. Seven silicone oils with different shear and extensional viscosities were tested. Two sets of eye movements were used: (amplitude 9 degrees, angular velocity 390 degrees/s, duration 50 ms) and (amplitude 90 degrees, angular velocity 360 degrees/s, duration 300 ms). The movements were captured and analyzed by video recording. RESULTS. The angular velocity of an oil bubble relative to the eye chamber appears to form an exponential relationship with its shear viscosity. Depending on the thickness of the film of aqueous between the eye wall and the oil bubble, the shear rate was estimated to be between 6 and 14 x 10(4) s(-1). The addition of 10% of 423-kDa PDMS to 1000 mPa . s silicone oil significantly reduced the peak relative velocity compared with the base oil of 1000 mPa . s but not 5000 mPa . s. CONCLUSIONS. The addition of high molecular components to a base oil increases its extensional and shear viscosity. Although the extensional viscosity affected the ease with which the oil could be injected, the results showed that it was the shear viscosity that determined the relative velocity between the oil and the wall of the vitreous cavity, and thus the propensity to emulsify. (Invest Ophthalmol Vis Sci. 2011; 52: 9721-9727) DOI: 10.1167/iovs. 11-8586
引用
收藏
页码:9721 / 9727
页数:7
相关论文
共 25 条
[1]   Development of Emulsification-Resistant Silicone Oils: Can We Go Beyond 2000 mPas Silicone Oil? [J].
Caramoy, Albert ;
Hagedorn, Nadine ;
Fauser, Sascha ;
Kugler, Wilfried ;
Gross, Theresia ;
Kirchhof, Bernd .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (08) :5432-5436
[2]   In vitro emulsification assessment of new silicone oils [J].
Caramoy, Albert ;
Schroeder, Sabine ;
Fauser, Sascha ;
Kirchhof, Bernd .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (04) :509-512
[3]   Detection of the slipped extraocular muscle after strabismus surgery [J].
Chen, SI ;
Knox, PC ;
Hiscott, P ;
Marsh, IB .
OPHTHALMOLOGY, 2005, 112 (04) :686-693
[4]  
CRISP A, 1987, ARCH OPHTHALMOL-CHIC, V105, P546
[5]   CONTACT ANGLES OF SUBSTANCES USED FOR INTERNAL TAMPONADE IN RETINAL-DETACHMENT SURGERY [J].
FAWCETT, IM ;
WILLIAMS, RL ;
WONG, D .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1994, 232 (07) :438-444
[6]   Signal-dependent noise determines motor planning [J].
Harris, CM ;
Wolpert, DM .
NATURE, 1998, 394 (6695) :780-784
[7]  
Heidenkummer H P, 1990, Fortschr Ophthalmol, V87, P226
[8]   EXPERIMENTAL EVALUATION OF INVITRO STABILITY OF PURIFIED POLYDIMETHYLSILOXANES (SILICONE OIL) IN VISCOSITY RANGES FROM 1000 TO 5000 CENTISTOKES [J].
HEIDENKUMMER, HP ;
KAMPIK, A ;
THIERFELDER, S .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1992, 12 (03) :S28-S32
[9]   The impact of axial length on retinal tamponade for gas, silicone oil, and heavy silicone oil, using an in vitro model [J].
Hillier, Roxane J. ;
Stappler, Theodor ;
Williams, Rachel L. ;
Turner, George S. ;
Wong, David .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (05) :671-675
[10]  
Knox PC, 2000, INVEST OPHTH VIS SCI, V41, P2561