Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial

被引:708
作者
Bolinder, Jan [1 ]
Antuna, Ramiro [2 ]
Geelhoed-Duijvestijn, Petronella [3 ]
Kroeger, Jens [4 ]
Weitgasser, Raimund [5 ,6 ]
机构
[1] Karolinska Univ, Karolinska Inst, Dept Med, Huddinge Hosp, S-14186 Stockholm, Sweden
[2] Clinidiabet, Corrida, Gijon, Spain
[3] Med Ctr Haaglanden, Dept Internal Med, The Hague, Netherlands
[4] Ctr Diabetol Hamburg Bergedorf, Hamburg, Germany
[5] Wehrle Diakonissen Hosp Salzburg, Dept Internal Med, Salzburg, Austria
[6] Paracelsus Med Univ, Salzburg, Austria
关键词
INSULIN-PUMP THERAPY; BLOOD-GLUCOSE; CARDIOVASCULAR-DISEASE; VARIABILITY; REDUCTION; EFFICACY; EPISODES; RISK;
D O I
10.1016/S0140-6736(16)31535-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Tight control of blood glucose in type 1 diabetes delays onset of macrovascular and microvascular diabetic complications; however, glucose levels need to be closely monitored to prevent hypoglycaemia. We aimed to assess whether a factory-calibrated, sensor-based, flash glucose-monitoring system compared with self-monitored glucose testing reduced exposure to hypoglycaemia in patients with type 1 diabetes. Methods In this multicentre, prospective, non-masked, randomised controlled trial, we enrolled adult patients with well controlled type 1 diabetes (HbA(1c) <= 58 mmol/mol [7.5%]) from 23 European diabetes centres. After 2 weeks of all participants wearing the blinded sensor, those with readings for at least 50% of the period were randomly assigned (1:1) to flash sensor-based glucose monitoring (intervention group) or to self-monitoring of blood glucose with capillary strips (control group). Randomisation was done centrally using the biased-coin minimisation method dependent on study centre and type of insulin administration. Participants, investigators, and study staff were not masked to group allocation. The primary outcome was change in time in hypoglycaemia (<3.9 mmol/L [70 mg/dL]) between baseline and 6 months in the full analysis set (all participants randomised; excluding those who had a positive pregnancy test during the study). This trial was registered with ClinicalTrials.gov,number NCT02232698. Findings Between Sept 4, 2014, and Feb 12, 2015, we enrolled 328 participants. After the screening and baseline phase, 120 participants were randomly assigned to the intervention group and 121 to the control group, with outcomes being evaluated in 119 and 120, respectively. Mean time in hypoglycaemia changed from 3.38 h/day at baseline to 2.03 h/day at 6 months (baseline adjusted mean change -1.39) in the intervention group, and from 3.44 h/day to 3.27 h/day in the control group (-0.14); with the between-group difference of -1.24 (SE 0.239; p<0.0001), equating to a 38% reduction in time in hypoglycaemia in the intervention group. No device-related hypoglycaemia or safety issues were reported. 13 adverse events were reported by ten participants related to the sensor-four of allergy events (one severe, three moderate); one itching (mild); one rash (mild); four insertion-site symptom (severe); two erythema (one severe, one mild); and one oedema (moderate). There were ten serious adverse events (five in each group) reported by nine participants; none were related to the device. Interpretation Novel flash glucose testing reduced the time adults with well controlled type 1 diabetes spent in hypoglycaemia. Future studies are needed to assess the effectiveness of this technology in patients with less well controlled diabetes and in younger age groups.
引用
收藏
页码:2254 / 2263
页数:10
相关论文
共 34 条
[1]   Association of hypoglycemic symptoms with patients' rating of their health-related quality of life state: a cross sectional study [J].
Alvarez-Guisasola, Fernando ;
Yin, Donald D. ;
Nocea, Gonzalo ;
Qiu, Ying ;
Mavros, Panagiotis .
HEALTH AND QUALITY OF LIFE OUTCOMES, 2010, 8
[2]  
[Anonymous], 1994, HDB PSYCHOL DIABETES
[3]   The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial [J].
Battelino, T. ;
Conget, I. ;
Olsen, B. ;
Schuetz-Fuhrmann, I. ;
Hommel, E. ;
Hoogma, R. ;
Schierloh, U. ;
Sulli, N. ;
Bolinder, J. .
DIABETOLOGIA, 2012, 55 (12) :3155-3162
[4]   Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes [J].
Battelino, Tadej ;
Phillip, Moshe ;
Bratina, Natasa ;
Nimri, Revital ;
Oskarsson, Per ;
Bolinder, Jan .
DIABETES CARE, 2011, 34 (04) :795-800
[5]   The Effect of Continuous Glucose Monitoring in Well-Controlled Type 1 Diabetes [J].
Beck, Roy W. .
DIABETES CARE, 2009, 32 (08) :1378-1383
[6]   Threshold-Based Insulin-Pump Interruption for Reduction of Hypoglycemia [J].
Bergenstal, Richard M. ;
Klonoff, David C. ;
Garg, Satish K. ;
Bode, Bruce W. ;
Meredith, Melissa ;
Slover, Robert H. ;
Ahmann, Andrew J. ;
Welsh, John B. ;
Lee, Scott W. ;
Kaufman, Francine R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (03) :224-232
[7]   Sensor-Augmented Pump Therapy for A1C Reduction (STAR 3) Study [J].
Bergenstal, Richard M. ;
Tamborlane, William V. ;
Ahmann, Andrew ;
Buse, John B. ;
Dailey, George ;
Davis, Stephen N. ;
Joyce, Carol ;
Perkins, Bruce A. ;
Welsh, John B. ;
Willi, Steven M. ;
Wood, Michael A. .
DIABETES CARE, 2011, 34 (11) :2403-2405
[8]   Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Tamborlane, William V. ;
Ahmann, Andrew ;
Buse, John B. ;
Dailey, George ;
Davis, Stephen N. ;
Joyce, Carol ;
Peoples, Tim ;
Perkins, Bruce A. ;
Welsh, John B. ;
Willi, Steven M. ;
Wood, Michael A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04) :311-320
[9]   Self-monitoring of blood glucose in type I diabetic patients: Comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions [J].
Bolinder, J ;
HagstromToft, E ;
Ungerstedt, U ;
Arner, P .
DIABETES CARE, 1997, 20 (01) :64-70
[10]  
Childs BP, 2005, DIABETES CARE, V28, P1245