Chlorhexidine alcohol versus povidone-iodine: The comparative study of skin disinfectants at the blood transfusion centers of Iran

被引:1
作者
Rafiee, M. H. [1 ]
Kafiabad, S. A. [1 ]
Maghsudlu, M. [1 ]
Moradi, M. [1 ,2 ]
Jalili, L. [1 ]
机构
[1] High Inst Res & Educ Transfus Med, Blood Transfus Res Ctr, Tehran, Iran
[2] Univ Isfahan, Fac Biol Sci & Technol, Dept Biotechnol, Esfahan, Iran
关键词
Chlorhexidine; Povidone-iodine; Blood donors; Disinfectant; Antiseptic; BACTERIAL-CONTAMINATION; DONORS;
D O I
10.1016/j.tracli.2020.01.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. - The skin disinfection in the blood donor's arm is a key step to minimize the risk of microbial contamination at blood donation sessions. Current study aimed to compare the efficacy of 2% chlorhexidine gluconate in 70% isopropyl alcohol (CHG/IPA) with povidone-Iodine (PI) at blood transfusion centers (BTCs) of Iran. Material and methods. - Blood donors were selected to evaluate three commercial CHG/IPA disinfectants (N= 300), prior the application at BTCs, and to compare the rate of positive skin cultures between CHG/IPA and PI in 31 BTCs (N= 8578). The rate of positivity for PI over a 5-year period was also investigated. After application of a two-step disinfection procedure, the biochemical characteristics were checked in accordance with the conventional bacteriological methods. The Z-test analysis was used to compare the deviation between the positive microbial culture ratios. Result. - No donors had a positive culture after disinfection during the evaluation study. There was no difference in the rate of positivity between PI and CHG/IPA after disinfection (P > 0.05). The rate of positivity for PI from 2012 to 2017 showed a decreasing trend. The rate of positivity was significantly higher in winter rather than summer (P < 0.05). Conclusion. - The disinfection efficacy of CHG/IPA was equivalent to that of PI. The 5-year monitoring of PI at BTCs showed that the improvement in the rate of positive skin cultures possibly due to effectiveness of correcting actions. (C) 2020 Societe francaise de transfusion sanguine (SFTS). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:78 / 82
页数:5
相关论文
共 20 条
[1]  
Administration UFaD, 2011, FAT REP FDA FOLL BLO
[2]   Skin disinfection with a single-step 2% chlorhexidine swab is more effective than a two-step povidone-iodine method in preventing bacterial contamination of apheresis platelets [J].
Benjamin, Richard J. ;
Dy, Beth ;
Warren, Ryan ;
Lischka, Michael ;
Eder, Anne F. .
TRANSFUSION, 2011, 51 (03) :531-538
[3]  
Blajchman M A, 2002, Dev Biol (Basel), V108, P59
[4]  
Bueno JL, 2010, TRANSFUSION, V50, P5, DOI 10.1111/j.1537-2995.2009.02513.x
[5]  
Calogiuri G.F., 2013, Journal of Allergy Therapy, V4, P141, DOI DOI 10.4172/2155-6121.1000141
[6]   Antimicrobial activity of two techniques for arm skin disinfection of blood donors in Brazil [J].
Celere, M. S. ;
Ferreira, O. ;
Ubiali, E. M. A. ;
Juliao, F. C. ;
Fernandes, A. F. T. ;
de Andrade, D. ;
Segura-Munoz, S. I. .
TRANSFUSION MEDICINE, 2012, 22 (02) :116-121
[7]  
Cid J, 2003, HAEMATOLOGICA, V88, P839
[8]   Evaluation of donor skin disinfection methods [J].
Goldman, M ;
Roy, G ;
Frechette, N ;
Decary, F ;
Massicotte, L ;
Delage, G .
TRANSFUSION, 1997, 37 (03) :309-312
[9]  
Kakaiya R, 2008, TECHNICAL MANUAL
[10]  
Mcdonald C, 1994, TRANSFUSION MED S1, V4, P56