An unfixed piecewise-optimal reactive power-flow model and its algorithm for AC-DC systems

被引:35
作者
Yu, Juan [1 ]
Yan, Wei [1 ]
Li, Wenyuan [2 ]
Chung, C. Y. [3 ]
Wong, K. P. [3 ]
机构
[1] Chongqing Univ, Elect Engn Coll, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] British Columbia Transmiss Corp, Vancouver, BC V7X 1V5, Canada
[3] Hong Kong Polytech Univ, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
AC-DC power system; capability limits of synchronous generator; generator reactive power costs; interior point method (IPM); optimal reactive power flow (ORPF);
D O I
10.1109/TPWRS.2007.907387
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel ac-dc optimal reactive power flow (ORPF) model with the generator capability limits is proposed. The objective is to minimize the total cost of generator reactive and active power outputs paid by an independent transmission company. In the model, the generator operation area is divided into four parts with each one having a different reactive output cost function. The boundaries between the four parts change with operation states of generators and are unfixed. The model is an unfixed piecewise mixed-integer nonlinear programming problem. A heuristic approach is introduced into the interior point method to solve the unfixed piecewise problem. The numerical results of six test systems that range in size from 14 to 2572 buses demonstrate the effectiveness of the proposed method.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 17 条
[1]   A method for simulation and analysis of reactive power market [J].
Ahmed, S ;
Strbac, G .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (03) :1047-1052
[2]  
Arrillaga J., 1998, AC DC POWER SYSTEM A
[3]   Optimal power flow by enhanced genetic algorithm [J].
Bakirtzis, AG ;
Biskas, PN ;
Zoumas, CE ;
Petridis, V .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (02) :229-236
[4]   Reactive power as an ancillary service [J].
Bhattacharya, K ;
Zhong, J .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2001, 16 (02) :294-300
[5]  
ELHAWARY ME, 1996, 96TP1110 IEEE OES
[6]   Cost analysis of reactive power support [J].
Lamont, JW ;
Fu, J .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1999, 14 (03) :890-895
[7]  
Li WY, 1989, SECURE EC OPERATION
[8]   Reactive power optimisation with voltage stability consideration in power market systems [J].
Lin, X ;
David, AK ;
Yu, CW .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (03) :305-310
[9]   An extended nonlinear primal-dual interior-point algorithm for reactive-power optimization of large-scale power systems with discrete control variables [J].
Liu, MB ;
Tso, SK ;
Cheng, Y .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (04) :982-991
[10]   THE INCORPORATION OF HVDC EQUATIONS IN OPTIMAL POWER FLOW METHODS USING SEQUENTIAL QUADRATIC-PROGRAMMING TECHNIQUES [J].
LU, CN ;
CHEN, SS ;
ONG, CM .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1988, 3 (03) :1005-1011