Feasibility of transcatheter closure of multiple defects within the oval fossa

被引:22
作者
Ewert, P [1 ]
Berger, F [1 ]
Kretschmar, O [1 ]
Abdul-Khaliq, H [1 ]
Stiller, B [1 ]
Lange, PE [1 ]
机构
[1] German Heart Inst, Dept Congenital Heart Dis, D-13353 Berlin, Germany
关键词
congenital heart disease; interatrial septal defects; interventional catheterisation;
D O I
10.1017/S1047951101000348
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Multiple perforations in the floor of the oval fossa may be an obstacle for transcatheter closure. Thus, we analyzed the interventions in 33 patients with more than one interatrial communication in comparison with 370 procedures with a single defect. Methods and Results: A diagnostic catheterization, which included a balloon-sizing maneuver, was performed. We implanted a total of 46 occluders, made up of 42 Amplatzers and 4 CardioSEALs. In 20 patients, the defects were dosed with a single occluder, namely 18 Amplatzer and 2 CardioSEAL devices. Complete closure was achieved in 15 patients, while a tiny residual shunt remained in 5 patients. In 13 patients, two devices were implanted, without any residual shunt being found immediately after implantation. In 3 patients, the occluders did not touch each other. In 10 patients, their rims overlapped. In comparison with the control group, the group with multiple defects did not differ in the distribution of age, gender, and indications for device closure. The mean time of the procedure, and the time required for fluoroscopy, however, were significant longer (P<0.001). These times ranged from 45 to 250 minutes with a median of 140 minutes, and from 0.0 to 39.2 minutes, with a median of 12.0 minutes, respectively. Also, the association with an atrial septal aneurysm was significantly more frequent (61 vs. 17%; P<0.001). The times taken during insertion of double devices were also significantly longer than those needed for insertion of a single device (P<0.001). Conclusions: Transcatheter closure of multiple defects within the oval fossa is feasible with currently available occluders, albeit than, in selected cases it is necessary to implant two devices.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 9 条
  • [1] Transcatheter closure as standard treatment for most interatrial defects:: experience in 200 patients treated with the Amplatzer™ Septal Occluder
    Berger, F
    Ewert, P
    Björnstad, PG
    Dähnert, I
    Krings, G
    Brilla-Austgenat, I
    Vogel, M
    Lange, PE
    [J]. CARDIOLOGY IN THE YOUNG, 1999, 9 (05) : 468 - 473
  • [2] BERGER F, 1997, DEUT MED WOCHENSCHR, V122, P137
  • [3] Prevention of stroke recurrence with presumed paradoxical embolism
    Bogousslavsky, J
    Devuyst, G
    Nendaz, M
    Yamamoto, H
    Sarasin, F
    [J]. JOURNAL OF NEUROLOGY, 1997, 244 (02) : 71 - 75
  • [4] Diagnostic catheterization and balloon sizing of atrial septal defects by echocardiographic guidance without fluoroscopy
    Ewert, P
    Berger, F
    Daehnert, I
    Krings, G
    Dittrich, S
    Lange, PE
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (02): : 159 - 163
  • [5] Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device (CardioSEAL)
    Kaulitz, R
    Paul, T
    Hausdorf, G
    [J]. HEART, 1998, 80 (01) : 54 - 59
  • [6] Transcatheter closure of atrial septal defects using the Cardio-Seal implant
    Pedra, CAC
    Pihkala, J
    Lee, KJ
    Boutin, C
    Nykanen, DG
    McLaughlin, PR
    Harrison, DA
    Freedom, RM
    Benson, L
    [J]. HEART, 2000, 84 (03) : 320 - 326
  • [7] Pedra CAC, 1998, CATHETER CARDIO DIAG, V45, P257, DOI 10.1002/(SICI)1097-0304(199811)45:3<257::AID-CCD8>3.0.CO
  • [8] 2-U
  • [9] Early clinical experience with use of the 'Amplatzer Septal Occluder' device for atrial septal defect
    Wilkinson, JL
    Goh, TH
    [J]. CARDIOLOGY IN THE YOUNG, 1998, 8 (03) : 295 - 302