Pulsed and CW adjustable 1942 nm single-mode all-fiber Tm-doped fiber laser system for surgical laser soft tissue ablation applications

被引:43
作者
Huang, Yize [1 ]
Jivraj, Jamil [1 ]
Zhou, Jiaqi [2 ]
Ramjist, Joel [1 ]
Wong, Ronnie [1 ]
Gu, Xijia [2 ]
Yang, Victor X. D. [1 ,3 ,4 ,5 ]
机构
[1] Ryerson Univ, Dept Elect & Comp Engn, Biophoton & Bioengn Lab, 350 Victoria St, Toronto, ON M5B 2K3, Canada
[2] Ryerson Univ, Dept Elect & Comp Engn, Fiber Opt Commun & Sensing Lab, 350 Victoria St, Toronto, ON M5B 2K3, Canada
[3] Univ Toronto, Fac Med, Div Neurosurg, 27 Kings Coll Cir, Toronto, ON M5S 1A1, Canada
[4] Sunnybrook Hlth Sci Ctr, Div Neurosurg, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
[5] Sunnybrook Res Inst, Phys Sci Program, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Heat affected zone - Thulium - Pulsed lasers - Tissue - Laser surgery - Optical tomography - Fiber lasers - Fibers - Flow of gases;
D O I
10.1364/OE.24.016674
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A surgical laser soft tissue ablation system based on an adjustable 1942 nm single-mode all-fiber Tm-doped fiber laser operating in pulsed or CW mode with nitrogen assistance is demonstrated. Ex vivo ablation on soft tissue targets such as muscle (chicken breast) and spinal cord (porcine) with intact dura are performed at different ablation conditions to examine the relationship between the system parameters and ablation outcomes. The maximum laser average power is 14.4 W, and its maximum peak power is 133.1 W with 21.3 mu J pulse energy. The maximum CW power density is 2.33 x 10(6) W/cm(2) and the maximum pulsed peak power density is 2.16 x 10(7) W/cm(2). The system parameters examined include the average laser power in CW or pulsed operation mode, gain-switching frequency, total ablation exposure time, and the input gas flow rate. The ablation effects were measured by microscopy and optical coherence tomography (OCT) to evaluate the ablation depth, superficial heat-affected zone diameter (HAZD) and charring diameter (CD). Our results conclude that the system parameters can be tailored to meet different clinical requirements such as ablation for soft tissue cutting or thermal coagulation for future applications of hemostasis. (C) 2016 Optical Society of America
引用
收藏
页码:16674 / 16686
页数:13
相关论文
共 20 条
[1]   Thulium:YAG 2 μm cw laser prostatectomy: where do we stand? [J].
Bach, T. ;
Xia, S. J. ;
Yang, Y. ;
Mattioli, S. ;
Watson, G. M. ;
Gross, A. J. ;
Herrmann, T. R. W. .
WORLD JOURNAL OF UROLOGY, 2010, 28 (02) :163-168
[2]  
Bilici T., 2009, EUROPEAN C LASERS EL, pCL
[3]  
Cao D., 2010, APPL PHYS B, V103, P83
[4]  
Castillejo M., 2014, Lasers in Materials Science
[5]   Endobronchial therapy with a thulium fiber laser (1940 nm) [J].
Gesierich, Wolfgang ;
Reichenberger, Frank ;
Fertl, Andreas ;
Haeussinger, Karl ;
Sroka, Ronald .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (06) :1827-1832
[6]   OPTICAL-CONSTANTS OF WATER IN 200-NM TO 200-MUM WAVELENGTH REGION [J].
HALE, GM ;
QUERRY, MR .
APPLIED OPTICS, 1973, 12 (03) :555-563
[7]   Clinical Ultrafast Laser Surgery: Recent Advances and Future Directions [J].
Hoy, Christopher L. ;
Ferhanoglu, Onur ;
Yildirim, Murat ;
Kim, Ki Hyun ;
Karajanagi, Sandeep S. ;
Chan, Ka Man Carmen ;
Kobler, James B. ;
Zeitels, Steven M. ;
Ben-Yakar, Adela .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2014, 20 (02)
[8]   Cross relaxation and energy transfer upconversion processes relevant to the functioning of 2 μm Tm3+-doped silica fibre lasers [J].
Jackson, SD .
OPTICS COMMUNICATIONS, 2004, 230 (1-3) :197-203
[9]   REFRACTIVE-INDEXES OF WATER AND ICE IN THE 0.65-MU-M TO 2.5-MU-M SPECTRAL RANGE [J].
KOU, LH ;
LABRIE, D ;
CHYLEK, P .
APPLIED OPTICS, 1993, 32 (19) :3531-3540
[10]   First experiences with a 2.0-μm near infrared laser system for neuroendoscopy [J].
Ludwig H.C. ;
Kruschat T. ;
Knobloch T. ;
Teichmann H.-O. ;
Rostasy K. ;
Rohde V. .