Study of dioxin removal by activated carbon

被引:4
作者
Furubayashi, M [1 ]
Shinohara, R
Nagai, K
机构
[1] Hitachi Zosen Co Ltd, Environm Syst Technol Res Ctr, Tech Res Inst, Osaka 5510022, Japan
[2] Hitachi Zosen Co Ltd, Proc Equipment Design & Engn Dept, Osaka 5598559, Japan
关键词
activated carbon; dioxin; 1,2,3,4-tetrachlorinated dibenzo-p-dioxin; adsorption; removal; mass transfer; fixed bed;
D O I
10.1252/kakoronbunshu.27.236
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Dioxin removal by activated carbon is studied by using a fixed bed type column and 1,2,3,4-tetrachlorinated dibenzo-p-dioxin (T4CDD). Effects of running time, T4CDD concentration of inlet gas, amount of activated carbon used, valid particle diameter of activated carbon, gas temperature, and superficial gas velocity in the column on T4CDD removal were analyzed and cleared. The effects were explained by the model that T4CDD removal is controlled by mass transfer rate in a boundary film on activated carbon particles and in the pores of them. T4CDD removal is little affected by the existence of 1,2,3-trichlorobenzen and sulfur dioxide in the gas phase, and is enhanced by the existence of hydrochloride in the gas phase.
引用
收藏
页码:236 / 242
页数:7
相关论文
共 5 条
  • [1] ERGUN S, 1952, CHEM ENG PROG, V48, P89
  • [2] FURUBAYASHI M, 1998, P 9 ANN C JAP SOC WA, P705
  • [3] Diffusion coefficients in gaseous systems
    Gilliland, ER
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1934, 26 : 681 - 685
  • [4] LOUIS J, 1968, IND ENG CHEM FUND, V7, P274
  • [5] NAGAI K, 1998, HITACHI ZOSEN TECHNI, V59, P2