IN VITRO STUDIES AND SAFETY ASSESSMENT OF DOPPLER ULTRASOUND AS A DIAGNOSTIC TOOL IN RHINOSINUSITIS

被引:3
作者
Sahlstrand-Johnson, Pernilla [1 ]
Jonsson, Peter [2 ]
Persson, Hans W. [4 ]
Holmer, Nils-Gunnar [3 ]
Jannert, Magnus
Jansson, Tomas [4 ]
机构
[1] Lund Univ, Skane Univ Hosp, Dept Otorhinolaryngol, Fac Med, S-20502 Malmo, Sweden
[2] Chalmers Univ Technol, Dept Appl Phys, S-41296 Gothenburg, Sweden
[3] Skane Univ Hosp, Dept Biomed Engn, S-20502 Malmo, Sweden
[4] Lund Univ, Dept Elect Measurements, S-20502 Malmo, Sweden
关键词
Acoustic streaming; Doppler ultrasound; Sinusitis; Rhinosinusitis; Sinus fluid; Viscosity; Attenuation; Safety assessment; MAXILLARY SINUSITIS;
D O I
10.1016/j.ultrasmedbio.2010.08.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We have previously proposed the use of Doppler ultrasound to noninvasively stage a sinus infection. In this study, we first investigated the acoustic properties of nonpurulent and mucopurulent sinus secretions. The density, viscosity, speed of sound and attenuation of 18 samples of sinus fluid were examined. We then assessed the safety of the method by determining the temperature increase when ultrasound is transmitted through a bone sample of the same thickness as the anterior wall of the maxillary sinus. As a measure of the probability to generate acoustic streaming, we determined the ratio of sound attenuation over the viscosity of the sinus fluid and compared this with the value obtained from acoustic streaming measurements on a model system. The results indicated that detectable levels of acoustic streaming can be generated in serous sinus fluid, which has a low viscosity, but is very unlikely in mucopurulent secretions. The attenuation of the mucopurulent sinus fluid was 10 times higher than that of the serous cyst fluid, but the viscosity of the mucopurulent secretion was a thousand times higher than that of serous fluid. The safety experiments gave a temperature increase of the bone of <1.5 degrees C at I-spta of 640 mW/cm(2), below the temperature increase considered to be harmful by the World Federation for Ultrasound in Medicine and Biology. (E-mail: pernilla.sahlstrand_johnson@med.lu.se) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2123 / 2131
页数:9
相关论文
共 50 条
  • [31] Automated Synovium Segmentation in Doppler Ultrasound Images for Rheumatoid Arthritis Assessment
    Yeung, Pak-Hei
    Tan, York-Kiat
    Xu, Shuoyu
    MEDICAL IMAGING 2018: COMPUTER-AIDED DIAGNOSIS, 2018, 10575
  • [32] Perceptions of Doppler ultrasound for rheumatoid arthritis disease activity assessment and education
    Joshua, Fredrick
    Bailey, Christine
    Marabani, Mona
    Romas, Evange
    White, Raymond
    Wong, Peter
    INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2019, 22 (01) : 55 - 61
  • [33] Doppler ultrasound compared to shear wave elastography for assessment of liver cirrhosis
    Ellaban, Heba Said
    Afify, Sameh Abdel Mawgoud
    Abdelgawad, Mohamed Saied
    EGYPTIAN JOURNAL OF INTERNAL MEDICINE, 2024, 36 (01)
  • [34] Color Doppler Ultrasound Assessment of Clinical Activity in Inflammatory Bowel Disease
    Celikyay, F.
    Yuksekkaya, R.
    Yuksekkaya, M.
    Kefeli, A.
    CURRENT MEDICAL IMAGING, 2021, 17 (06) : 741 - 750
  • [35] Volumetric flow estimation in vivo and in vitro using pulsed-Doppler ultrasound
    Holland, CK
    Clancy, MJ
    Taylor, KJW
    Alderman, JL
    Purushothaman, K
    McCauley, TR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (05) : 591 - 603
  • [36] Use of an ultrasound blood-mimicking fluid for Doppler investigations of turbulence in vitro
    Thorne, Meghan L.
    Poepping, Tamie L.
    Rankin, Richard N.
    Steinman, David A.
    Holdsworth, David W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (07) : 1163 - 1173
  • [37] Flow Rate and Low Hematocrit Measurements for In Vitro Blood Processing With Doppler Ultrasound
    Pialot, Baptiste
    Gachelin, Jeremie
    Tanter, Mickael
    Provost, Jean
    Couture, Olivier
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (07) : 1293 - 1302
  • [38] Power Doppler ultrasound assessment of ovarian perifollicular blood flow women with polycystic ovaries and normal ovaries during in vitro fertilaztion treatment
    Costello, MF
    Shrestha, SM
    Sjoblom, P
    McNally, G
    Bennett, MJ
    Steigrad, SJ
    Hughes, GJ
    FERTILITY AND STERILITY, 2005, 83 (04) : 945 - 954
  • [39] Diagnostic Accuracy of Doppler Ultrasound in the Diagnosis of Testicular Carcinoma by Taking Histopathology as Gold Standard
    Sahito, Abid Ali
    Ahsanullah
    Kumar, Vicky
    Hussain, Mohsim
    Ashraf, Humaira
    Jabeen, Humera
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (47A) : 447 - 451
  • [40] Design and Implementation of AADL Model Safety Assessment Tool
    Zhao, Hongbing
    Song, Deming
    Dong, Yunwei
    2012 12TH INTERNATIONAL CONFERENCE ON QUALITY SOFTWARE (QSIC), 2012, : 251 - 257