Reliability Evaluation of Tidal Current Farm Integrated Generation Systems Considering Wake Effects

被引:13
|
作者
Ren, Zhouyang [1 ]
Li, Hui [1 ]
Li, Wenyuan [1 ]
Zhao, Xueqian [2 ]
Sun, Yihao [3 ]
Li, Te [4 ]
Jiang, Fan [5 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] State Grid Beijing Elect Power Res Inst, Beijing 1310905, Peoples R China
[3] State Grid Henan Econ Res Inst, Zhengzhou 450052, Henan, Peoples R China
[4] State Grid Zhejiang Elect Power Res Inst, Hangzhou 310008, Zhejiang, Peoples R China
[5] State Grid Chongqing Elect Power Co, Maintenance Branch Co, Chongqing 400039, Peoples R China
来源
IEEE ACCESS | 2018年 / 6卷
基金
中国国家自然科学基金;
关键词
Tidal current generation; wake effects; reliability evaluation; sequential Monte Carlo; power system planning; CURRENT TURBINE; POWER; ENERGY; SPEEDS; MODEL;
D O I
10.1109/ACCESS.2018.2866387
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Based on a sequential Monte-Carlo simulation technique, a reliability evaluation method and several indices are proposed for tidal current farm integrated generation systems in this paper. A tidal current velocity model is first developed to capture the chronology and randomness of tidal current velocity by combining a fuzzy equivalent matrix-based clustering approach with a nonparametric probabilistic modeling technique. The single and multiple wake effects between tidal current turbines in a tidal current farm are quantitatively represented using an analytical wake model. Second, a power output model for a tidal current farm (TCF) is proposed, incorporating the characteristics of tidal current velocity, wake effects and turbine failures. A sequential Monte-Carlo simulation-based reliability evaluation method, as well as several reliability evaluation indices are proposed to quantify the impacts of TCF integration and wake effects on the reliability level of generation systems. The historical tidal current velocity data collected from a site located in FL, USA, and the popular reliability test system known as RBTS with an additional TCF were used to verify the accuracy and effectiveness of the proposed method. The impacts of tidal power integration and the relative distances between turbines in TCF on generation systems' reliability were also studied.
引用
收藏
页码:52616 / 52624
页数:9
相关论文
共 50 条
  • [21] Effects of Switch Type and Location on the Reliability of Power Distribution Systems Considering Distributed Generation
    Heidari, Alireza
    Agelidis, Vassilios G.
    Naderi, Mohammad Salay
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2013, : 710 - 715
  • [22] Effects of Automation on the Reliability of Power Distribution Systems Considering Distributed Generation: Worth Analysis
    Heidari, Alireza
    Agelidis, Vassilios G.
    Naderi, Mohammad Salay
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2013, : 1733 - 1738
  • [23] Integrated Reliability Evaluation of Distribution and Sub-Transmission Systems Incorporating Distributed Generation
    Andrade, Waltencir S.
    Borges, Carmen L. T.
    Falcao, Djalma M.
    2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1910 - +
  • [24] Reliability Evaluation of DC/DC Converter in Direct Current Collection System of Wind Farm Considering the Influence of Control Strategy
    Liu, Junyi
    Fan, Yanfang
    Hou, Junjie
    Bai, Xueyan
    PROCESSES, 2023, 11 (10)
  • [25] Optimal layout of a Co-Located wind/tidal current farm considering forbidden zones
    Tao, Siyu
    Xu, Qingshan
    Feijoo-Lorenzo, Andres E.
    Zheng, Gang
    Zhou, Jiemin
    ENERGY, 2021, 228
  • [26] An optimal operation strategy of wind farm for frequency regulation reserve considering wake effects
    Tian, Sheng
    Liu, Yongqian
    Li, Baoliang
    Chi, Yongning
    Tian, Xinshou
    ENERGY, 2024, 304
  • [27] Comprehensive evaluation method for tidal current power generation device
    Yongqiang ZHU
    Xin WANG
    Qing YE
    Chunming DUAN
    Journal of Modern Power Systems and Clean Energy, 2016, 4 (04) : 702 - 708
  • [28] Comprehensive evaluation method for tidal current power generation device
    Zhu, Yongqiang
    Wang, Xin
    Ye, Qing
    Duan, Chunming
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2016, 4 (04) : 702 - 708
  • [29] Study on Reliability Assessment of Composite Generation and Transmission System Integrated Wind Farm
    Cao, Fang
    Gao, Xiang
    Yu, Junwei
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2012,
  • [30] Stochastic Economic Dispatch of a Power System With Solar Farm Considering Generation Flexibility and Reliability
    Sabzevari, Asghar
    Moazzami, Majid
    Fani, Bahador
    Shahgholian, Ghazanfar
    Hashemi, Mahnaz
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2024, 2024 (01)