Dimeric versus monomeric nonionic contrast agents in visualization of coronary arteries

被引:13
作者
Rienmüller, R [1 ]
Brekke, O [1 ]
Kampenes, VB [1 ]
Reiter, U [1 ]
机构
[1] Univ Klinikum Graz, Landeskrankenhaus, Div Gen Radiol, A-8036 Graz, Austria
关键词
iodixanol; iohexol; coronary artery imaging; electron beam computed tomography;
D O I
10.1016/S0720-048X(01)00304-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A cubital intravenous iodine contrast agent enhancement is used to visualize coronary arteries using EBT. The quality of the coronary artery visualization however is limited by the nearly simultaneous approximation of CT values in coronary arteries and myocardial tissue. The objective of the study was to evaluate if "under real clinical circumstances" the lower iodine concentration and the dimeric based characteristic or iodixanol may effect the kinetic of the applied contrast agent and the visualization of coronary arteries studied noninvasively by EBT. A double-blind, randomized, parallel study was performed in 111 cardiac patients, using iodixanol 270 mg I/ml or iohexol 300 mg I/ml. The kinetics of contrast enhancement was studied in the flow mode measuring following parameters: mean arrival time and mean time to reach peak CT values in the pulmonary trunk, transit time from the pulmonary trunk to the aorta as well as mean and maximum CT values in the left ventricular chamber and in the myocardium with respect to the body mass index. The mean difference of CT values in the left ventricular chamber and the myocardium was calculated. The length of the visualized coronary arteries was assessed and the diagnostic quality of coronary artery visualization scored on a visual analogue scale. Although iodixanol was used with a Power iodine concentration than iohexol there was no significant statistical difference between both groups with respect to the diagnostic visualization and length assessment of the coronary arteries as well as in the mean difference of CT values in the left ventricular chamber and the myocardium. This means that the advantageous dimeric characteristics of iodixanol may be used to reduce the amount of applicated iodine in contrast agents without loss of diagnostic image quality and information. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:173 / 178
页数:6
相关论文
共 9 条
[1]   FIRST EXPERIENCES IN ULTRAFAST CT OF THE HEART - A COMPARISON TO ANGIOGRAPHIC AND ECHOCARDIOGRAPHIC FINDINGS [J].
KOSLING, S ;
HOFFMANN, U ;
LIEBERENZ, S ;
ROTHER, T ;
WEBER, P ;
HEYWANGKOBRUNNER, SH ;
SCHULZ, HG .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (02) :111-118
[2]  
MANNINEN H, 1995, EUR RADIOL, V5, P364
[3]  
MUETZEL W, 1984, INVEST RADIOL, V19, pS140
[4]   Electron-beam-computed-tomography of the heart [J].
Rienmuller, R ;
Kern, R ;
Baumgartner, C ;
Hackel, B .
RADIOLOGE, 1997, 37 (05) :410-416
[5]  
Rienmuller R, 1997, HERZ, V22, P63, DOI 10.1007/BF03044305
[6]  
SAKO M, 1993, NIPPON ACTA RADIOL, V54, P32
[7]   Quantitative evaluation of regional myocardial perfusion using fast x-ray computed tomography [J].
Schmermund, A ;
Bell, MR ;
Lerman, LO ;
Ritman, EL ;
Rumberger, JA .
HERZ, 1997, 22 (01) :29-39
[8]  
STANFORD W, 1991, SEMIN ULTRASOUND CT, V12, P45
[9]  
THOMPSON BH, 1994, RADIOL CLIN N AM, V32, P537