Simulation of Water Equivalency of Polymer Gel Dosimeters with GAMOS

被引:0
作者
Ozbay, Turkan [1 ,2 ]
Yurt, Aysegul [2 ,3 ]
Ozsoykal, Ismail [2 ]
机构
[1] Izmir Univ Econ, Vocat Sch Hlth Serv, Izmir, Turkey
[2] Dokuz Eylul Univ, Dept Med Phys, Izmir, Turkey
[3] Dokuz Eylul Univ, Vocat Sch Hlth Serv, Izmir, Turkey
来源
JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES | 2020年 / 4卷 / 01期
关键词
Polymer gel; Dosimeter; Monte Carlo; GAMOS; Simulation; RADIATION-DOSE DISTRIBUTIONS; X-RAY; RADIOLOGICAL PROPERTIES; FRAMEWORK; TOOL; CT;
D O I
10.30621/jbachs.2020.899
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: Polymer gel materials are used as dosimeters to provide three dimensional radiation dose distribution. An ideal gel dosimeter should offer radiological properties equivalent to water. This study aims to determine and compare the water equivalencies of various new polymer gel mixtures using Geant4-based Architecture for Medicine-Oriented Simulations (GAMOS) software program. Methods: To do this, percentage depth dose curves of the simulated polymer gel mixtures were compared with water curves. Different combinations of materials from 2 main classes were used in the mixtures: (1) Sodium Carboxymethyl Cellulose (SODIUM CMC), Polyvinyl Alcohol (PVA) and Polyethylene Glycol (PEG) as gel matrix, (2) 2-Hydroxyethyl Methacrylate (HEMA), 1-Vinyl-2-Pyrrolidinone (VP) and Diethylene Glycol Dimethacrylate (DEGDMA) as monomer. Each mixture also contained ultra-pure water and an antioxidant material called Tetrakis Hydroxymethyl Phosphonium Chloride ( THPC). Results: Percentage depth doses of gel mixtures and water was calculated for 6, 18 MV and 50, 70, 100, 150 kVp X rays. The mixture sample showing radiological behavior nearest to water over all energies was observed to be 31a (Water, PEG, HEMA, THPC), while the largest difference is observed in 11a (Water, SODIUM CMC, HEMA, THPC). Conclusion: As a result, simulated gel formulations were found to be radiologically water equivalent.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 32 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] Aldrich Sigma, 2019, ACR PROP PROD CAT 20
  • [3] Simulation framework and XML detector description for the CMS experiment
    Arce, P
    Banerjee, S
    Boccali, T
    Case, M
    de Roeck, A
    Lara, V
    Liendl, M
    Nikitenko, A
    Schroder, M
    Straessner, A
    Wellisch, HP
    Wenzel, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 502 (2-3) : 687 - 688
  • [4] GAMOS: A framework to do GEANT4 simulations in different physics fields with an user-friendly interface
    Arce, Pedro
    Ignacio Lagares, Juan
    Harkness, Laura
    Perez-Astudillo, Daniel
    Canadas, Mario
    Rato, Pedro
    de Prado, Maria
    Abreu, Yamiel
    de Lorenzo, Gianluca
    Kolstein, Machiel
    Diaz, Angelina
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 735 : 304 - 313
  • [5] Polymer gel dosimetry
    Baldock, C.
    De Deene, Y.
    Doran, S.
    Ibbott, G.
    Jirasek, A.
    Lepage, M.
    McAuley, K. B.
    Oldham, M.
    Schreiner, L. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) : R1 - R63
  • [6] Experimental study of attenuation properties of normoxic polymer gel dosimeters
    Brindha, S
    Venning, AJ
    Hill, B
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (20) : N353 - N361
  • [7] De Deene Y, 2000, MAGN RESON MED, V43, P116, DOI 10.1002/(SICI)1522-2594(200001)43:1<116::AID-MRM14>3.0.CO
  • [8] 2-5
  • [9] MCNP™ Version 5
    Forster, RA
    Cox, LJ
    Barrett, RF
    Booth, TE
    Briesmeister, JF
    Brown, FB
    Bull, JS
    Geisler, GC
    Goorley, JT
    Mosteller, RD
    Post, SE
    Prael, RE
    Selcow, EC
    Sood, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 82 - 86
  • [10] Radiological characterization and water equivalency of genipin gel for x-ray and electron beam dosimetry
    Gorjiara, Tina
    Hill, Robin
    Kuncic, Zdenka
    Bosi, Stephen
    Davies, Justin B.
    Baldock, Clive
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15) : 4685 - 4699