CAPILLARY ZONE ELECTROPHORESIS IN DETERMINATION OF MICROORGANISMS

被引:0
作者
Klodzinska, Ewa [1 ]
Tanase, Stefania [1 ,2 ]
Tomescu, Andra Alina [1 ,2 ]
Moga, Marius [2 ]
Buszewski, Boguslaw [1 ]
机构
[1] Nicolas Copernicus Univ, Fac Chem, Chair Environm Chem & Bioanalyt, PL-87100 Torun, Poland
[2] Transylvania Univ Brasov, Fac Med, Brasov 500036, Romania
关键词
electrophoresis of bacteria; medical diagnosis; detection methods; RAPID IDENTIFICATION; HELICOBACTER-PYLORI; FOOD ANALYSIS; SEPARATION; BACTERIA;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electromigration techniques have been recently proposed as a replacement for traditional methods of microbial identification. The results of the initial experiments indicate that diagnostics based on this technology can be extremely sensitive, inexpensive and, primarily, very fast. Capillary electrophoresis is a novel method of chemical analysis which enables separation and identification of various chemical substances. Characterized by high efficiency, repeatability of results, sensitivity toward detected substances and reliability, this technique is also extremely cost-saving as it requires small amounts of chemical substrates to be used. This study was carried out to summarized our achievements and experimental results in separation and identification of bacteria by electromigration techniques, to examine microbial behavior during separation process.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 23 条
[1]  
ALBERT K, 2008, ON LINE LC NMR RELAT
[2]   Rapid identification of Helicobacter pylori by capillary electrophoresis:: an overview [J].
Buszewski, B. ;
Klodzinska, E. ;
Dahm, H. ;
Rozycki, H. ;
Szeliga, J. ;
Jackowski, M. .
BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) :116-122
[3]   Determination of pathogenic bacteria by CZE with surface-modified capillaries [J].
Buszewski, Boguslaw ;
Klodzinska, Ewa .
ELECTROPHORESIS, 2008, 29 (20) :4177-4184
[4]  
Camilleri P., 1998, CAPILLARY ELECTROPHO
[5]   Recent advances in the application of capillary electromigration methods for food analysis [J].
Cifuentes, A .
ELECTROPHORESIS, 2006, 27 (01) :283-303
[6]  
DESAI MJ, 2003, ARMSTRONG MICROBIOL, P38
[7]   Capillary electrophoresis in food analysis [J].
Dong, YY .
TRENDS IN FOOD SCIENCE & TECHNOLOGY, 1999, 10 (03) :87-93
[8]  
EBERSOLE RC, 1993, BIO-TECHNOL, V11, P1278
[9]  
Evans AlfredS., 1998, BACTERIAL INFECT HUM, VThird
[10]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61