Accuracy of automated blood pressure recorders in pregnancy

被引:11
|
作者
Brown, MA [1 ]
Robinson, A [1 ]
Buddle, ML [1 ]
机构
[1] St George Hosp, Dept Renal Med, Kogarah, NSW 2217, Australia
关键词
D O I
10.1111/j.1479-828X.1998.tb03062.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Automated blood pressure recorders are used with increasing frequency by pregnant women, mostly without proper evaluation of their accuracy. We compared blood pressures (BP) recorded by 2 automated noninvasive devices, the Spacelabs 90207 ambulatory blood pressure monitor and the OMRON HEM 705 CP portable selfinitiated device, with blood pressures recorded by routine sphygmomanometry in 79 pregnant women either considered 'at risk' for preeclampsia or,with mild hypertension in pregnancy. The Spacelabs device tended to overestimate systolic BP by a mean 11 (SD=8) mmHg and diastolic BP by 5 (SD=7) mmHg for phase 5 pressure (p<0.001) but was similar to routine BPs for diastolic phase 4 pressures. The OMRON device tended to underestimate diastolic (phase 4) pressure by 4 (SD=6) mmHg (p<0.001) but gave similar systolic and diastolic (phase 5) pressures to routine sphygmomanometry. However, for both devices there was considerable individual patient variability in accuracy. When using these devices to record a limited number of blood pressure recordings, as in this study, we suggest that individual comparison with mercury sphygmomanometry be made in each pregnant woman before accepting the validity of these recordings.
引用
收藏
页码:262 / 265
页数:4
相关论文
共 50 条
  • [21] ACCURACY OF BRACHIAL BLOOD PRESSURE RECORDINGS BY AUTOMATED CUFF COMPARED TO CENTRAL AORTIC PRESSURE
    Schwartz, L.
    Mighton, L. D.
    Dunlop, J.
    Shufelt, K.
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 : 125D - 125D
  • [22] Accuracy of Automated Blood Pressure Measurement in Children Evidence, Issues, and Perspectives
    Stergiou, George S.
    Boubouchairopoulou, Nadia
    Kollias, Anastasios
    HYPERTENSION, 2017, 69 (06) : 1000 - 1006
  • [23] Accuracy of automated oscillometric blood pressure monitors in the detection of cardiac arrhythmias
    Huang, Qi-Fang
    Sheng, Chang-Sheng
    Zhang, Yi
    Wang, Jie
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2009, 14 (02) : 91 - 92
  • [24] Automated Office Blood Pressure and the Impact of Attendance and Rest on Diagnostic Accuracy
    Green, Beverly B.
    Anderson, Melissa L.
    Cook, Andrea J.
    Ehrlich, Kelly
    Hall, Yoshio N.
    Margolis, Karen L.
    Thompson, Matthew J.
    AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (07) : 638 - 646
  • [25] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Jennifer S. Ringrose
    Raj Padwal
    Journal of Human Hypertension, 2023, 37 : 101 - 107
  • [26] Calibration accuracy of hospital based automated blood pressure devices.
    Hoffmann, A.
    Lorde, I
    Shennan, A. H.
    HYPERTENSION IN PREGNANCY, 2006, 25 : 164 - 164
  • [27] Accuracy of the automated oscillography electronic device in measuring blood pressure in children
    Zhang, Yi
    Cheng, Yi
    Wang, Qian
    Jiang, Yuan
    Yan, Weili
    CARDIOLOGY, 2013, 126 : 18 - 18
  • [28] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Ringrose, Jennifer S.
    Padwal, Raj
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (02) : 101 - 107
  • [29] Accuracy of automated community pharmacy-based blood pressure devices
    Gonzalvo, Jasmine
    Zillich, Alan
    JOURNAL OF THE AMERICAN PHARMACISTS ASSOCIATION, 2011, 51 (03) : 408 - 411
  • [30] AN EVALUATION OF AUTOMATED INDIRECT BLOOD-PRESSURE MEASUREMENT DURING PREGNANCY
    MILSOM, I
    SVAHN, SO
    FORSSMAN, L
    SIVERTSSON, R
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1986, 65 (07) : 721 - 725