Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode

被引:23
作者
Motghare, Ramani V. [1 ]
Tadi, Kiran Kumar [1 ]
Dhawale, Payal [1 ]
Deotare, Samiksha [2 ]
Kawadkar, Aruna K. [3 ]
Chillawar, Rakesh [1 ]
Khan, Shirinaz [1 ]
机构
[1] Visvesvaraya Natl Inst Technol, Dept Chem, Nagpur 440010, Maharashtra, India
[2] Govt Med Coll, Nagpur 440011, Maharashtra, India
[3] Inst Sci, Dept Zool, Nagpur 440011, Maharashtra, India
关键词
Computational chemistry; Stripping voltammetry; Electrochemical sensors; Molecularly imprinted polymer; Carbon paste electrode; Uric acid; ASCORBIC-ACID; GLASSY-CARBON; FOLIC-ACID; ELECTROCHEMICAL SENSOR; FILM; ALLANTOIN; PLASMA;
D O I
10.1002/elan.201400579
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Molecularly imprinted polymer (MIP) for uric acid (UA) was synthesized by thermal polymerization using acrylic acid (AA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross linker and 2,2-azobis(2-isobutyro) nitrile (AIBN) as initiator. The noncovalent interactions involved in four possible conformations of pre-polymer complex were computationally studied by density functional theory. The hydrogen bond formation between UA and AA was confirmed by Fourier transform infrared (FTIR) spectrum of the MIP before extraction of UA. After extraction of the template, the molecularly imprinted polymer based carbon paste electrode (MIPCPE) was fabricated under optimized conditions. A significant enhancement in the electrocatalytic oxidation of UA was found at MIPCPE. The electrochemical behavior of sensor was investigated by cyclic voltammetry (CV) and differential pulse adsorptive stripping voltammetry (DPAdSV). The electrochemical impedance spectroscopy (EIS) studies revealed less charge transfer resistance (R-ct) at MIPCPE than NIPCPE. Under optimized conditions, calibration curve was obtained with a linearity range of 0.5 mu M to 100 mu M and the limit of detection was 0.1 mu M. The sensor showed good selectivity towards UA in the presence of interferents and was successfully applied for the determination of UA in spiked serum samples.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 42 条
[1]   Development of a voltammetric sensor based on a molecularly imprinted polymer (MIP) for caffeine measurement [J].
Alizadeh, Taher ;
Ganjali, Mohamad Reza ;
Zare, Mashaalah ;
Norouzi, Parviz .
ELECTROCHIMICA ACTA, 2010, 55 (05) :1568-1574
[2]  
Baghbamidi S. E., 2013, CHINESE J CATAL, V34, P1
[3]  
Bard AJ., 2001, ELECTROCHEMICAL METH, V2nd, P368
[4]   Electrocatalytic and simultaneous determination of isoproterenol, uric acid and folic acid at molybdenum (VI) complex-carbon nanotube paste electrode [J].
Beitollahi, Hadi ;
Sheikhshoaie, Iran .
ELECTROCHIMICA ACTA, 2011, 56 (27) :10259-10263
[5]   Application of a Carbon-Paste Electrode Modified with 2,7-Bis(ferrocenyl ethyl)fluoren-9-one and Carbon Nanotubes for Voltammetric Determination of Levodopa in the Presence of Uric Acid and Folic Acid [J].
Beitollahi, Hadi ;
Raoof, Jahan-Bakhsh ;
Hosseinzadeh, Rahman .
ELECTROANALYSIS, 2011, 23 (08) :1934-1940
[6]   Carbon-nanotube-modified glassy carbon electrode for simultaneous determination of dopamine, ascorbic acid and uric acid: The effect of functional groups [J].
Bi, Huaqing ;
Li, Yanhui ;
Liu, Shufeng ;
Guo, Peizhi ;
Wei, Zhongbin ;
Lv, Chunxiao ;
Zhang, Jizhen ;
Zhao, X. S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 :1132-1140
[7]   Electrochemical sensors based on molecularly imprinted polymers [J].
Blanco-López, MC ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (01) :36-48
[8]   An amperometric biosensor for uric acid determination prepared from uricase immobilized in polypyrrole film [J].
Cete, Servet ;
Yasar, Ahmet ;
Arslan, Fatma .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2006, 34 (03) :367-380
[9]   A disposable single-use electrochemical sensor for the detection of uric acid in human whole blood [J].
Chen, JC ;
Chung, HH ;
Hsu, CT ;
Tsai, DM ;
Kumar, AS ;
Zen, JM .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (02) :364-369
[10]   Detection of uric acid based on multi-walled carbon nanotubes polymerized with a layer of molecularly imprinted PMAA [J].
Chen, Po-Yen ;
Nien, Po-Chin ;
Hu, Chih-Wei ;
Ho, Kuo-Chuan .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (02) :466-471