Normal Functional Range of Motion of the Cervical Spine During 15 Activities of Daily Living

被引:56
作者
Bible, Jesse E. [1 ]
Biswas, Debdut [1 ]
Miller, Christopher P. [1 ]
Whang, Peter G. [1 ]
Grauer, Jonathan N. [1 ]
机构
[1] Yale Univ, Sch Med, Dept Orthopaed & Rehabil, New Haven, CT 06520 USA
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2010年 / 23卷 / 01期
关键词
cervical; spine; range of motion; activities of daily living; TOTAL KNEE ARTHROPLASTY; REDUCED NECK MOBILITY; FOLLOW-UP; SPONDYLOTIC MYELOPATHY; ANKLE KINEMATICS; GLOBAL MOTION; STAIR ASCENT; ACTIVE RANGE; DISC; FUSION;
D O I
10.1097/BSD.0b013e3181981632
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Prospective clinical study. Objective: The purpose of this investigation was to quantify normal cervical range of motion (ROM) and compare these results to those used to perform 15 simulated activities of daily living (ADLs) in asymptomatic subjects. Summary of Background Data: Previous studies looking at cervical ROM during ADLs have been limited and used measuring devices that do not record continuous motion. The purpose of this investigation was to quantify normal cervical ROM and compare these results with those used to perform 15 simulated ADLs in asymptomatic subjects. Methods: A noninvasive electrogoniometer and torsiometer were used to measure the ROM of the cervical spine. The accuracy and reliability of the devices were confirmed by comparing the ROM values acquired from dynamic flexion/extension and lateral bending radiographs to those provided by the device, which was activated while the radiographs were obtained. Intraobserver reliability was established by calculating the intraclass correlation coefficient for repeated measurements on the same subjects by 1 investigator on consecutive days. These tools were employed in a clinical laboratory setting to evaluate the full active ROM of the cervical spines (ie, flexion/extension, lateral bending, and axial rotation) of 60 asymptomatic subjects (30 females and 30 males; age, 20 to 75 y) as well as to assess the functional ROM required to complete 15 simulated ADLs. Results: When compared with radiographic measurements, the electrogoniometer was found to be accurate within 2.3 +/- 2.2 degrees (mean +/- SD) and the intraobserver reliabilities for measuring the full active and functional ROM were both excellent (intraclass correlation coefficient of 0.96 and 0.92, respectively). The absolute ROM and percentage of full active cervical spinal ROM used during the 15 ADLs was 13 to 32 degrees and 15% to 32% (median, 20 degrees/19%) for flexion/extension, 9 to 21 degrees and 11% to 27% (14 degrees/18%) for lateral bending, and 13 to 57 degrees and 12% to 92% (18 degrees/19%) for rotation. Backing up a car required the most ROM of all the ADLs, involving 32% of sagittal, 26% of lateral, and 92% of rotational motion. In general, personal hygiene ADLs such as washing hands and hair, shaving, and applying make-up entailed a significantly greater ROM relative to locomotive ADLs including walking and traveling up and down a set of stairs (P < 0.0001); in addition, compared with climbing up these steps, significantly more sagittal and rotational motion was used when descending stairs (P = 0.003 and P = 0.016, respectively). When picking up an object from the ground, a squatting technique required a lower percentage of lateral and rotational ROM than bending at the waist (P = 0.002 and P < 0.0001). Conclusions: By quantifying the amounts of cervical motion required to execute a series of simulated ADLs, this study indicates that most individuals use a relatively small percentage of their full active ROM when performing such activities. These findings provide baseline data which may allow clinicians to accurately assess preoperative impairment and postsurgical outcomes.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 49 条
  • [1] Evaluation of spinal kinematics following lumbar total disc replacement and circumferential fusion using in vivo fluoroscopy
    Auerbach, Joshua D.
    Wills, Brian P. D.
    McIntosh, Theresa C.
    Balderston, Richard A.
    [J]. SPINE, 2007, 32 (05) : 527 - 536
  • [2] Active range of motion utilized in the cervical spine to perform daily functional tasks
    Bennett, SE
    Schenk, RJ
    Simmons, ED
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (04): : 307 - 311
  • [3] Cervical spondylotic myelopathy: Complications and outcomes after spinal fusion
    Boakye, Maxwell
    Patil, Chirag G.
    Santarelli, Justin
    Ho, Chris
    Tian, Wendy
    Lad, Shivanand P.
    [J]. NEUROSURGERY, 2008, 62 (02) : 455 - 461
  • [4] CONTINUOUS MEASUREMENT OF LUMBAR POSTURE USING FLEXIBLE ELECTROGONIOMETERS
    BOOCOCK, MG
    JACKSON, JA
    BURTON, AK
    TILLOTSON, KM
    [J]. ERGONOMICS, 1994, 37 (01) : 175 - 185
  • [5] Validation of the NHANES ADL scale in a sample of patients with report of cervical pain: Factor analysis, item response theory analysis, and line item validity
    Cook, Chad E.
    Richardson, Jan K.
    Pietrobon, Ricardo
    Braga, Larissa
    Silva, Henrique Martins
    Turner, Dennis
    [J]. DISABILITY AND REHABILITATION, 2006, 28 (15) : 929 - 935
  • [6] Knee and hip kinetics during normal stair climbing
    Costigan, PA
    Deluzio, KJ
    Wyss, UP
    [J]. GAIT & POSTURE, 2002, 16 (01) : 31 - 37
  • [7] ANALYSIS OF SPINE MOTION VARIABILITY USING A COMPUTERIZED GONIOMETER COMPARED TO PHYSICAL-EXAMINATION - A PROSPECTIVE CLINICAL-STUDY
    DOPF, CA
    MANDEL, SS
    GEIGER, DF
    MAYER, PJ
    [J]. SPINE, 1994, 19 (05) : 586 - 595
  • [8] AGE AND GENDER RELATED NORMAL MOTION OF THE CERVICAL-SPINE
    DVORAK, J
    ANTINNES, JA
    PANJABI, M
    LOUSTALOT, D
    BONOMO, M
    [J]. SPINE, 1992, 17 (10) : S393 - S398
  • [9] Normal global motion of the cervical spine: an electrogoniometric study
    Feipel, V
    Rondelet, B
    Le Pallec, JP
    Rooze, M
    [J]. CLINICAL BIOMECHANICS, 1999, 14 (07) : 462 - 470
  • [10] Active range of motion of the head and cervical spine: a three-dimensional investigation in healthy young adults
    Ferrario, VF
    Sforza, C
    Serrao, G
    Grassi, G
    Mossi, E
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (01) : 122 - 129