Intertrochanteric Fracture Treated by Dynamic Hip Screw, Aden, Yemen

被引:0
作者
Mohsen, Abdulsalam Abdullah Hadi [1 ]
机构
[1] Univ Aden, Fac Med, Dept Special Surg, Orthoped Unit, Aden, Yemen
来源
WORLD FAMILY MEDICINE | 2021年 / 19卷 / 09期
关键词
dynamic hip screw; intertrochanteric fracture; femur; Aden; Yemen; PROXIMAL FEMORAL NAIL; GAMMA-NAIL; FEMUR; PLATE; ANTIROTATION; MORTALITY; FIXATION;
D O I
10.5742/MEWFM.2021.94122
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the clinical outcomes of Intertrochanteric fractures that were treated with Dynamic Hip Screw in Aden Patients and method: This was a retrospective study of patients presenting with intertrochanteric fracture, to the Department of Orthopaedic Surgery at Algamhoria Teaching Hospital and at two private hospital in Aden, Yemen, during the period January 2018-December 2019. The patients were treated with Dynamic Hip Screw (DHS). All information was obtained from the patient charts. The collected data was tabulated and statistical analysis was done by estimating rates ; means and standard deviations. Fisher test was used and p-value < 0.05 was considered as statistically significant. The statistical software package SPSS version 17 was used. Results: Out of 48 patients, 29 patients were females (60.4%) and 19 patients (39.6%) were males and the mean age was 75.1 +/- 7.4 years. The mean age of male patients was 76.4 +/- 6.9 years while for females was 74.2 +/- 7.7 years. The age ranged between 62 to 90 years. The patients were categorized into 3 age groups: Group (I) <= 70 years old. (27.1%) were females and (10.4%) were males, Group (II) from 71 - 80 years old. (20.8%) were females and (14.6%) were males. Group (III) from 81 - 90 years old, (12.5%) were females and (14.6%) were males, (p > 0.05). Causes of injury were simple fall in most of the cases (79.1%). The causes of injuries were significantly different among the age groups of patients (P < 0.05). We found (58.3%) of intertrochanteric fractures were in the right side and (41.7%) were in the left side. The stable fractures were (52.1%) while unstable fractures were (47.9%). According to Evan classifications (31.3%) of the intertrochanteric fractures were classified as Type I and (20.8%) were classified as Type II. Type III were predominant with (47.9%). Superficial stitch infection were (4.2%) and (4.2%) were deep infection. Shortening of 1-2cm occurred in (10.4%) of patients. Mal-union occurred in (20.8%) cases. Delayed union occurred in (10.4%) cases. Active physiotherapy is given regularly for delayed union. Deep vein thrombosis developed in (8.4%) of cases and pulmonary thrombosis occurred in (4.2%) of cases. Conclusion: The dynamic hip screw is a modality of choice in patients with intertrochanteric fracture; it is effective, simple, and safe. Further studies are needed to compare between our modality and other modalities.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 35 条
  • [1] Abdulkareem Imran Haruna, 2012, Niger Med J, V53, P184, DOI 10.4103/0300-1652.107550
  • [2] Minimally invasive dynamic hip screw - Prospective Randomized trial of two techniques of insertion of a standard dynamic fixation device
    Alobaid, A
    Harvey, EJ
    Elder, GM
    Lander, P
    Guy, P
    Reindl, R
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (04) : 207 - 212
  • [3] Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures
    Andruszkow, Hagen
    Frink, Michael
    Froemke, Cornelia
    Matityahu, Amir
    Zeckey, Christian
    Mommsen, Philipp
    Suntardjo, Stefanie
    Krettek, Christian
    Hildebrand, Frank
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (11) : 2347 - 2354
  • [4] Implant-related complications in the treatment of unstable intertrochanteric fractures:: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices
    Audigé, L
    Hanson, B
    Swiontkowski, MF
    [J]. INTERNATIONAL ORTHOPAEDICS, 2003, 27 (04) : 197 - 203
  • [5] GAMMA-NAIL VS COMPRESSION SCREW FOR TROCHANTERIC FEMORAL FRACTURES - 15 REOPERATIONS IN A PROSPECTIVE, RANDOMIZED STUDY OF 378 PATIENTS
    AUNE, AK
    EKELAND, A
    ODEGAARD, B
    GROGAARD, B
    ALHO, A
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02): : 127 - 130
  • [6] Intertrochanteric-subtrochanteric fractures:: Treatment with the long gamma nail
    Barquet, A
    Francescoli, L
    Rienzi, D
    López, L
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (05) : 324 - 328
  • [7] Results of intertrochanteric femur fractures treated with a 135-degree sliding screw with a two-hole side plate
    Bolhofner, BR
    Russo, PR
    Carmen, B
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (01) : 5 - 8
  • [8] FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW
    BRIDLE, SH
    PATEL, AD
    BIRCHER, M
    CALVERT, PT
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02): : 330 - 334
  • [9] Choi Won-Kee, 2015, Hip Pelvis, V27, P98, DOI 10.5371/hp.2015.27.2.98
  • [10] Unstable Proximal Femur Fractures Treated With Proximal Femoral Locking Plates: A Retrospective, Multicenter Study of 111 Cases
    Collinge, Cory A.
    Hymes, Robert
    Archdeacon, Michael
    Streubel, Phillip
    Obremskey, William
    Weber, Timothy
    Watson, J. Tracy
    Lowenberg, David
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (09) : 489 - 495