Trace Analysis of N-Nitrosamines in Water Using Solid-Phase Microextraction Coupled with Gas Chromatograph-Tandem Mass Spectrometry

被引:38
作者
Hung, Hsu-Wen [1 ]
Lin, Tsair-Fuh [1 ,2 ]
Chiu, Chuen-Huey [3 ]
Chang, Ya-Chi [3 ]
Hsieh, Tung-Ying [4 ]
机构
[1] Natl Cheng Kung Univ, Sustainable Environm Res Ctr, Tainan 70955, Taiwan
[2] Natl Cheng Kung Univ, Dept Environm Engn, Tainan 70101, Taiwan
[3] Natl Pingtung Univ Sci & Technol, Dept Environm Sci & Engn, Pingtung 91241, Taiwan
[4] Taiwan Water Corp, Dept Publ Works, Taichung 40455, Taiwan
关键词
N-nitrosamines; NDMA; Solid-phase microextraction; Drinking water; Water treatment plant; DRINKING-WATER; NITROSODIMETHYLAMINE NDMA; CHLORINE; NITROGEN; KINETICS; MTBE;
D O I
10.1007/s11270-010-0398-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A method that utilizes solid-phase microextraction (SPME) coupled with gas chromatography (GC) and chemical ionization tandem mass spectrometry (MS/MS) was developed for analyzing a group of emerging pollutants, N-nitrosamines, in water. The developed analytical method requires a water sample of less than 5 ml and only 1.5 h for complete analysis. The method detection limits for N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine, and N-nitrosodi-n-propylamine were in the range of 3.2 to 3.5 ng/l; for N-nitrosomorpholine, it was 15.2 ng/l. The method was successfully employed to measure the N-nitrosamine concentration at trace levels of nanogram per liter in four water treatment plants (WTPs) and one water distribution system. In the WTPs, only NDMA was detected in the treatment processes. Within the treatment train, NDMA was observed after chlorination. The level of NDMA significantly declined after slow sand filtration due presumably to microbial degradation. The NDMA concentration collected from consumer tap water was about 40% higher on average than that in the finished water. The excellent performance of the SPME/GC/MS/MS method in various water matrices as well as the shorter analysis time and smaller sample volume compared to currently used extraction techniques makes it an alternative means for the analysis of N-nitrosamine in drinking water, wastewater, and laboratory research with small reactors.
引用
收藏
页码:459 / 469
页数:11
相关论文
共 28 条
[1]  
Alpendurada MD, 2000, J CHROMATOGR A, V889, P3
[2]   A method for the determination of volatile N-nitrosamines in food by HS-SPME-GC-TEA [J].
Andrade, R ;
Reyes, FGR ;
Rath, S .
FOOD CHEMISTRY, 2005, 91 (01) :173-179
[3]  
APHA (AMERICAN PUBLIC HEALTH ASSOCIATION), 1995, Standard Methods for the Examination of Water and Waste Water
[4]  
BARRETT S, 2003, P ANN AM WAT WORKS A
[5]  
*CDPH, 2008, NDMA OTH NITR DRINK
[6]   Breakpoint chlorination and free-chlorine contact time:: Implications for drinking water N-nitrosodimethylamine concentrations [J].
Charrois, Jeffrey W. A. ;
Hrudey, Steve E. .
WATER RESEARCH, 2007, 41 (03) :674-682
[7]   Detecting N-nitrosamines in drinking water at nanogram per liter levels using ammonia positive chemical ionization [J].
Charrois, JWA ;
Arend, MW ;
Froese, KL ;
Hrudey, SE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (18) :4835-4841
[8]  
Cheng RC, 2006, J AM WATER WORKS ASS, V98, P82
[9]   Solid-phase microextraction of N-nitrosamines [J].
Grebel, Janel E. ;
Young, Connie C. ;
Suffet, I. H. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (01) :11-18
[10]   Nitrogen-phosphorus detection and nitrogen chemiluminescence detection of volatile nitrosamines in water matrices: Optimization and performance comparison [J].
Grebel, Janel E. ;
Suffet, I. H. Mel .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1175 (01) :141-144