Heparin coating of the stent graft - effects on platelets, coagulation and complement activation

被引:83
作者
Christensen, K
Larsson, R [1 ]
Emanuelsson, H
Elgue, G
Larsson, A
机构
[1] Univ Uppsala Hosp, Dept Oncol Radiol & Clin Immunol, Complement & Biomat Grp, Uppsala, Sweden
[2] Med Ctr Hosp, Div Cardiol, Orebro, Sweden
[3] Univ Hosp, Dept Med Sci Clin Chem, Uppsala, Sweden
关键词
stent; platelets; coagulation; heparin surface; in vitro study;
D O I
10.1016/S0142-9612(00)00190-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this investigation was to assess the effect of heparin coating of a new stent construction (Stent Graft(TM), Jomed Implantate GmbH, Germany) on platelet and coagulation activity. Methods. Stent grafts with an ePTFE membrane interfoliated between two stents were deployed in tubings to form Chandler loops. Fresh human blood with a low concentration of heparin was rotated for 1 h, then collected and used for measurements of platelet number, thrombin-antithrombin complex (TAT), CD11b, C3a and C5b-9. There were five study groups: Group 1, conventional unmodified stents (n = 8); Group 2, untreated stent grafts (n = 8); Group 3, heparin-coated stents and untreated membrane (n = 7); Group 4, heparin-coated stents and membrane (n = 8); Group 5, heparin-coated PVC tubings with no stents (n = 8). Results. There was a significant drop in platelet count, increase in TAT-values and CD11b expression in Groups 1-3 but not in Group 4 compared to Group 5. Examination by scanning electron microscopy revealed extensive activation on non-modified stents but almost no deposition of thrombotic material on heparin-modified stent grafts. Conclusions. With unmodified stents and membrane there were signs of significant activation of platelets and coagulation. In contrast, the heparin-coated stent graft induced much less alterations, indicating improved blood compatibility. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 23 条
  • [21] Heparin-coated Palmaz-Schatz stents in human coronary arteries - Early outcome of the Benestent-II pilot study
    Serruys, PW
    Emanuelsson, H
    vanderGiessen, W
    Lunn, AC
    Kiemeney, F
    Macaya, C
    Rutsch, W
    Heyndrickx, G
    Suryapranata, H
    Legrand, V
    Goy, JJ
    Materne, P
    Bonnier, H
    Morice, MC
    Fajadet, J
    Belardi, J
    Colombo, A
    Garcia, E
    Ruygrok, P
    deJaegere, P
    Morel, MA
    [J]. CIRCULATION, 1996, 93 (03) : 412 - 422
  • [22] Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II)
    Serruys, PW
    van Hout, B
    Bonnier, H
    Legrand, V
    Garcia, E
    Macaya, C
    Sousa, E
    van der Giessen, W
    Colombo, A
    Seabra-Gomes, R
    Kiemeneij, F
    Ruygrok, P
    Ormiston, J
    Emanuelsson, H
    Fajadet, J
    Haude, M
    Klugmann, S
    Morel, MA
    [J]. LANCET, 1998, 352 (9129) : 673 - 681
  • [23] van Der Giessen WJ, 1999, Curr Interv Cardiol Rep, V1, P234