摘要
The purpose of this investigation was to assess the effect of heparin coating of a new stent construction (Stent Graft(TM), Jomed Implantate GmbH, Germany) on platelet and coagulation activity. Methods. Stent grafts with an ePTFE membrane interfoliated between two stents were deployed in tubings to form Chandler loops. Fresh human blood with a low concentration of heparin was rotated for 1 h, then collected and used for measurements of platelet number, thrombin-antithrombin complex (TAT), CD11b, C3a and C5b-9. There were five study groups: Group 1, conventional unmodified stents (n = 8); Group 2, untreated stent grafts (n = 8); Group 3, heparin-coated stents and untreated membrane (n = 7); Group 4, heparin-coated stents and membrane (n = 8); Group 5, heparin-coated PVC tubings with no stents (n = 8). Results. There was a significant drop in platelet count, increase in TAT-values and CD11b expression in Groups 1-3 but not in Group 4 compared to Group 5. Examination by scanning electron microscopy revealed extensive activation on non-modified stents but almost no deposition of thrombotic material on heparin-modified stent grafts. Conclusions. With unmodified stents and membrane there were signs of significant activation of platelets and coagulation. In contrast, the heparin-coated stent graft induced much less alterations, indicating improved blood compatibility. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 23 条
  • [1] Potential mechanisms promoting restenosis in diabetic patients
    Aronson, D
    Bloomgarden, Z
    Rayfield, EJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (03) : 528 - 535
  • [2] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [3] SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS
    DUSSAILLANT, GR
    MINTZ, GS
    PICHARD, AD
    KENT, KM
    SATLER, LF
    POPMA, JJ
    WONG, SC
    LEON, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) : 720 - 724
  • [4] GENERATION OF IC3 AT THE INTERFACE BETWEEN BLOOD AND GAS
    EKDAHL, KN
    NILSSON, B
    PEKNA, M
    NILSSON, UR
    [J]. SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1992, 35 (01) : 85 - 91
  • [5] EMANUELSSON H, 1997, HDB CORONARY STENTS, P187
  • [6] FUSTER V, 1995, THROMB HAEMOSTASIS, V74, P552
  • [7] RESTENOSIS AFTER CORONARY ANGIOPLASTY
    HAMON, M
    BAUTERS, C
    MCFADDEN, EP
    WERNERT, N
    LABLANCHE, JM
    DUPUIS, B
    BERTRAND, ME
    [J]. EUROPEAN HEART JOURNAL, 1995, 16 : 33 - 48
  • [8] PROLONGED PROLIFERATIVE RESPONSE OF SMOOTH-MUSCLE CELLS AFTER EXPERIMENTAL INTRAVASCULAR STENTING
    HANKE, H
    KAMENZ, J
    HASSENSTEIN, S
    OBERHOFF, M
    HAASE, KK
    BAUMBACH, A
    BETZ, E
    KARSCH, KR
    [J]. EUROPEAN HEART JOURNAL, 1995, 16 (06) : 785 - 793
  • [9] Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries
    Hardhammar, PA
    vanBeusekom, HMM
    Emanuelsson, HU
    Hofma, SH
    Albertsson, PA
    Verdouw, PD
    Boersma, E
    Serruys, PW
    vanderGiessen, WJ
    [J]. CIRCULATION, 1996, 93 (03) : 423 - 430
  • [10] CLINICAL AND ANGIOGRAPHIC OUTCOMES AFTER CORONARY-ARTERY STENTING FOR ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - INITIAL RESULTS WITH A BALLOON-EXPANDABLE, STAINLESS-STEEL DESIGN
    HEARN, JA
    KING, SB
    DOUGLAS, JS
    CARLIN, SF
    LEMBO, NJ
    GHAZZAL, ZMB
    [J]. CIRCULATION, 1993, 88 (05) : 2086 - 2096