Bone reactions adjacent to titanium implants subjected to static load of different duration. A study in the dog (III)

被引:84
作者
Gotfredsen, K
Berglundh, T
Lindhe, F
机构
[1] Univ Copenhagen, Fac Hlth Sci, Sch Dent, Dept Prosthet Dent, DK-2200 Copenhagen, Denmark
[2] Univ Gothenburg, Fac Odontol, Dept Periodontol, Gothenburg, Sweden
关键词
beagle; bone; fluorochrome; implant; osseointegration; static load; titanium;
D O I
10.1034/j.1600-0501.2001.120602.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of the present experiment was to study the effect of a long-standing lateral static load on the peri-implant bone. Three beagle dogs were used. The mandibular premolars were extracted and 12 weeks later 3 titanium implants (ITI(R) Dental Implant System) were installed in each quadrant. Crowns were fitted to all implants 12 weeks after the installation procedure. The anterior and central crowns were fused and connected to the posterior crown by an expansion screw. In the right side of the mandible, the expansion screws were activated every 2 weeks during a 46-week period. During the last 10 weeks of this period, an expansion force similar to that of the right side was applied in the left. The animals were sacrificed and block biopsies of each implant site harvested and prepared for histological analysis. Sites subjected to 10 weeks or 46 weeks of lateral load had a similar (i) distribution of bone markers (ii) proportion of bone density and (iii) degree of bone-to-implant contact. The proportion of fluorochromes was higher at sites subjected to 10 weeks of loading than at sites subjected to 46 weeks of loading.
引用
收藏
页码:552 / 558
页数:7
相关论文
共 12 条
  • [1] Reactions of peri-implant tissues to continuous loading of osseointegrated implants
    Akin-Nergiz, N
    Nergiz, I
    Schulz, A
    Arpak, N
    Niedermeier, W
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1998, 114 (03) : 292 - 298
  • [2] Titanium implants and lateral forces - An experimental study with sheep
    Asikainen, P
    Klemetti, E
    Vuillemin, T
    Sutter, F
    Rainio, V
    Kotilainen, R
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (06) : 465 - 468
  • [3] A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE
    DONATH, K
    BREUNER, G
    [J]. JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) : 318 - 326
  • [4] Bone reactions adjacent to titanium implants subjected to static load - A study in the dog (I)
    Gotfredsen, K
    Berglundh, T
    Lindhe, J
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) : 1 - 8
  • [5] GOTFREDSEN K, 2001, IN PRESS CLIN ORAL I
  • [6] Holmes D C, 1997, J Oral Implantol, V23, P104
  • [7] KARNOVSKY MJ, 1965, J CELL BIOL, V3, P112
  • [8] ROBERTS WE, 1989, ANGLE ORTHOD, V59, P247
  • [9] OSSEOUS ADAPTATION TO CONTINUOUS LOADING OF RIGID ENDOSSEOUS IMPLANTS
    ROBERTS, WE
    SMITH, RK
    ZILBERMAN, Y
    MOZSARY, PG
    SMITH, RS
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1984, 86 (02) : 95 - 111
  • [10] Stegaroiu R, 1998, INT J ORAL MAX IMPL, V13, P82