Effect of compressive strength and chloride diffusion on life cycle CO2 assessment of concrete containing supplementary cementitious materials

被引:77
作者
Zhang, Yurong [1 ,2 ]
Zhang, Junzhi [1 ,3 ]
Luo, Wei [2 ]
Wang, Jiandong [1 ]
Shi, Jiale [1 ]
Zhuang, Huaxia [1 ]
Wang, Yuanfeng [2 ]
机构
[1] Zhejiang Univ Technol, Coll Civil Engn & Architecture, 18 Chao Wang Rd, Hangzhou 310014, Zhejiang, Peoples R China
[2] Beijing Jiaotong Univ, Sch Civil Engn, 3 Shang Yuan Cun, Beijing 100044, Peoples R China
[3] Key Lab Civil Engn Struct & Disaster Prevent, Mitigat Technol Zhejiang Prov, Hangzhou 310014, Zhejiang, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Supplementary cementitious materials; Life cycle assessment; Chloride diffusion; Convection zone; Compressive strength; ENVIRONMENTAL-IMPACT; DURABILITY; FRAMEWORK; ZEOLITE; DESIGN;
D O I
10.1016/j.jclepro.2019.01.335
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Using supplementary cementitious materials (SCMs) in concrete is considered as one of the possible solutions to making green concrete. Previous research often analyzed the environmental impact of concrete without considering the influences of compressive strength and durability simultaneously. Such a practice will lead to less rational life cycle assessment (LCA) results, since the service life of concrete could be shortened when durability is poor, especially if concrete is exposed to marine dry-wet environment where chloride ion is intensive. Moreover, Fick's second law of diffusion was always used to determine the chloride diffusion coefficient of concrete, without considering the influences of convection zone and peak value of chloride concentration. Therefore, this paper proposed an integrated functional unit combining durability (resistance to chloride ion diffusion), compressive strength and volume to evaluate the environmental impact of concrete containing SCMs. The chloride diffusion coefficient was calculated by re-scaling the "zero" of penetration axis to calibrate Fick's second law of diffusion. In addition, three other functional units (volume, combining volume and compressive strength, combing volume and durability) were also proposed and compared. Results indicate that the selection of functional unit has a significant influence on the LCA results of the studied concrete. Despite the variation with different functional units, concrete containing silica fume or silica fume as well as fly ash shows a consistently superior environmental performance over the ordinary concrete. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:450 / 458
页数:9
相关论文
共 49 条
[1]  
Aitcin PC, 2011, MOD CONRETE TECHNOL, P1
[2]   Mathematical modeling of a concrete surface ''skin effect'' on diffusion in chloride contaminated media [J].
Andrade, C ;
Diez, LM ;
Alonso, C .
ADVANCED CEMENT BASED MATERIALS, 1997, 6 (02) :39-44
[3]  
[Anonymous], 2009, RES EIA READY MIXED
[4]  
[Anonymous], 2006, ISO 14040 2006 ENV M
[5]  
[Anonymous], 2009, CEM TECHN ROADM 2009
[6]   LCA allocation procedure used as an incitative method for waste recycling: An application to mineral additions in concrete [J].
Chen, C. ;
Habert, G. ;
Bouzidi, Y. ;
Jullien, A. ;
Ventura, A. .
RESOURCES CONSERVATION AND RECYCLING, 2010, 54 (12) :1231-1240
[7]   Life Cycle Assessment of Completely Recyclable Concrete [J].
De Schepper, Mieke ;
Van den Heede, Philip ;
Van Driessche, Isabel ;
De Belie, Nele .
MATERIALS, 2014, 7 (08) :6010-6027
[8]   Prediction of long-term chloride diffusion in silica fume concrete in a marine environment [J].
Farahani, Atiye ;
Taghaddos, Hosein ;
Shekarchi, Mohammad .
CEMENT & CONCRETE COMPOSITES, 2015, 59 :10-17
[9]   Probability distribution of convection zone depth of chloride in concrete in a marine tidal environment [J].
Gao, Yan-Hong ;
Zhang, Jun-Zhi ;
Zhang, Shan ;
Zhang, Yu-Rong .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 140 :485-495
[10]  
GE (GaBi Education), 2009, Handbook for Life Cycle Assessment (LCA), Using the GaBi Education Software Package, P60