Low-dose CT imaging of radio-opaque markers for assessing human rotator cuff repair: Accuracy, repeatability and the effect of arm position

被引:9
作者
Derwin, K. A. [1 ,2 ,3 ,4 ]
Milks, R. A. [1 ,2 ]
Davidson, I.
Iannotti, J. P. [1 ,2 ,3 ,4 ]
McCarron, J. A. [5 ]
Bey, M. J. [6 ]
机构
[1] Cleveland Clin, Dept Biomed Engn, Cleveland, OH 44195 USA
[2] Cleveland Clin, Orthoped & Rheumatol Res Ctr, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Orthoped Surg, Orthoped & Rheumatol Inst, Cleveland, OH 44195 USA
[4] Cleveland Clin, Cleveland Clin Lerner Coll Med, Cleveland, OH 44195 USA
[5] Dept VA Med Ctr, Orthoped Surg Sect, Portland, OR USA
[6] Henry Ford Hosp, Ctr Bone & Joint, Detroit, MI 48202 USA
关键词
CT imaging; Rotator cuff repair; Tantalum beads; ACHILLES-TENDON RUPTURES; TEARS; AGE;
D O I
10.1016/j.jbiomech.2011.11.046
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Previous studies have used radiostereometric analysis (RSA) to assess the integrity and mechanical properties of repaired tendons and ligament grafts. A conceptually similar approach is to use CT imaging to measure the 3D position and distance between implanted markers. The purpose of this study was to quantify the accuracy and repeatability of measuring the position and distance between metallic markers placed in the rotator cuff using low-dose CT imaging. We also investigated the effect of repeated or variable positions of the arm on position and distance measures. Six human patients had undergone rotator cuff repair and placement of tantalum beads in the rotator cuff at least one year prior to participating in this study. On a single day each patient underwent nine low-dose CT scans in seven unique arm positions. CT scans were analyzed to assess bias, precision and RMS error of the measurement technique. The effect of repeated or variable positions of the arm on the 3D position of the beads and the distance between these beads and suture anchors in the humeral head were also assessed. Results showed the CT imaging method is accurate and repeatable to within 0.7 mm. Further, measures of bead position and anchor-to-bead distance are influenced by arm position and location of the bead within the rotator cuff. Beads located in the posterior rotator cuff moved medially as much as 20 mm in abduction or external rotation. When clinically relevant CT arm positions such as the hand on umbilicus or at side were repeated, bead position varied less than 4 mm in any anatomic direction and anchor-to-bead distance varied +2.8 to 1.6 mm (RMS 1.3 mm). We conclude that a range of +/- 3 mm is a conservative estimate of the uncertainty in anchor-to-bead distance for patients repeatedly scanned in clinically-relevant arm positions. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:614 / 618
页数:5
相关论文
共 17 条
[1]  
ASTM International, 1996, West Conshockenvol., V96, P1
[2]   Rotator cuff repair failure in vivo: a radiostereometric measurement study [J].
Baring, Tobias K. A. ;
Cashman, Peter P. M. ;
Reilly, Peter ;
Emery, Roger J. H. ;
Amis, Andrew A. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (08) :1194-1199
[3]   Estimation of Dynamic, In Vivo Soft-Tissue Deformation: Experimental Technique and Application in a Canine Model of Tendon Injury and Repair [J].
Bey, Michael J. ;
Kline, Stephanie K. ;
Baker, Andrew R. ;
McCarron, Jesse A. ;
Iannotti, Joseph P. ;
Derwin, Kathleen A. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (06) :822-827
[4]   The influence of age, delay of repair, and tendon involvement in acute rotator cuff tears Structural and clinical outcomes after repair of 42 shoulders [J].
Bjornsson, Hanna C. ;
Norlin, Rolf ;
Johansson, Kajsa ;
Adolfsson, Lars E. .
ACTA ORTHOPAEDICA, 2011, 82 (02) :187-192
[5]   Temporal Evolution of MRI Findings After Arthroscopic Rotator Cuff Repair [J].
Crim, Julia ;
Burks, Robert ;
Manaster, Betty J. ;
Hanrahan, Christopher ;
Hung, Man ;
Greis, Patrick .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) :1361-1366
[6]   RSA can measure ACL graft stretching and migration - Development of a new method [J].
Khan, Rashid ;
Konyves, Arpad ;
Rama, K. R. Boddu Siva ;
Thomas, Rhidian ;
Amis, Andrew A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) :139-145
[7]   Prospective Randomized Clinical Trial of Single-Versus Double-Row Suture Anchor Repair in 2-to 4-cm Rotator Cuff Tears: Clinical and Magnetic Resonance Imaging Results [J].
Koh, Kyoung Hwan ;
Kang, Kyung Chung ;
Lim, Tae Kang ;
Shon, Min Soo ;
Yoo, Jae Chul .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (04) :453-462
[8]   ROTATOR-CUFF CHANGES IN ASYMPTOMATIC ADULTS - THE EFFECT OF AGE, HAND DOMINANCE AND GENDER [J].
MILGROM, C ;
SCHAFFLER, M ;
GILBERT, S ;
VANHOLSBEECK, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (02) :296-298
[9]   False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo [J].
Park, Maxwell C. ;
Tibone, James E. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (08) :911.e1-911.e4
[10]   Autologous Platelets Have No Effect on the Healing of Human Achilles Tendon Ruptures A Randomized Single-Blind Study [J].
Schepull, Thorsten ;
Kvist, Joanna ;
Norrman, Hanna ;
Trinks, Marie ;
Berlin, Gosta ;
Aspenberg, Per .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (01) :38-47