Quetiapine cross-reactivity with plasma tricyclic antidepressant immunoassays

被引:8
作者
Caravati, EM
Juenke, JM
Crouch, BI
Anderson, KT
机构
[1] Utah Poison Control Ctr, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Surg, Salt Lake City, UT 84112 USA
[3] Univ Utah, ARUP Labs, Salt Lake City, UT 84112 USA
[4] Univ Utah, Dept Pharmacotherapy, Salt Lake City, UT 84112 USA
关键词
tricyclic antidepressant immunoassay; false-positive; toxicology screen; quetiapine;
D O I
10.1345/aph.1G107
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
BACKGROUND: Toxicology screens obtained on patients who have overdosed on drugs frequently include tricyclic antidepressants (TCAs) as part of the evaluation. Quetiapine is an antipsychotic agent with structural similarity to the TCAs. OBJECTIVE: To determine whether quetiapine may cross-react with plasma TCA immunoassays in vitro using commonly available autoanalyzers. METHODS: Quetiapine stock solution was added to 9 separate samples of pooled drug-free human plasma to produce concentrations ranging from 1 to 640 ng/mL that were verified by gas chromatography. No quetiapine metabolites were present. Each spiked plasma sample was tested in a blinded fashion using the Abbott Tricyclic Antidepressant TDx Assay on the TDxFLx autoanalyzer in 2 separate laboratories, the Syva Emit tox Serum Tricyclic Antidepressant Assay on the AU400 autoanalyzer and the S TAD Serum Tricyclic Antidepressant Screen on the ACA-Star 300 autoanalyzer. The TDx assay is quantitative, while Emit and S TAD are qualitative screening assays with a threshold of 300 ng/mL for TCA positivity. The outcome of interest was a positive TCA result. RESULTS: The quantitative assay showed concentration-related TCA cross-reactivity beginning at quetiapine concentrations of 5 ng/mL. The 640-ng/mL spiked sample produced TCA results of 379 and 385 ng/mL in labs 1 and 2, respectively. The qualitative assays were screened as TCA positive at quetiapine concentrations of 160 and 320 ng/mL for the S TAD and Emit assays, respectively. CONCLUSIONS: Quetiapine cross-reacts with quantitative and qualitative plasma TCA immunoassays in a concentration-dependent fashion. Therapeutic use or overdose of quetiapine may result in a false-positive TCA immunoassay result.
引用
收藏
页码:1446 / 1449
页数:4
相关论文
共 14 条
  • [11] Sloan KL, 2000, AM J PSYCHIAT, V157, P148
  • [12] SORISKY A, 1986, CLIN CHEM, V32, P715
  • [13] WIANS FH, CLIN CHEM, V38, P1355
  • [14] National academy of clinical biochemistry laboratory medicine practice guidelines: Recommendations for the use of laboratory tests to support poisoned patients who present to the emergency department
    Wu, AHB
    McKay, C
    Broussard, LA
    Hoffman, RS
    Kwong, TC
    Moyer, TP
    Otten, EM
    Welch, SL
    Wax, P
    [J]. CLINICAL CHEMISTRY, 2003, 49 (03) : 357 - 379