Effects of graphene plates' adoption on the microstructure, mechanical properties, and in vivo biocompatibility of calcium silicate coating

被引:24
作者
Xie, Youtao [1 ]
Li, Hongqin [1 ]
Ding, Chuanxian [1 ]
Zheng, Xuebin [1 ]
Li, Kai [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Key Lab Inorgan Coating Mat, Shanghai 200050, Peoples R China
来源
INTERNATIONAL JOURNAL OF NANOMEDICINE | 2015年 / 10卷
基金
中国国家自然科学基金;
关键词
graphene plates; coating; microstructure; wear resistance; biocompatibility; CARBON NANOTUBES; ION IMPLANTATION; BONE; PARTICLES; COMPOSITE; PROLIFERATION; CELLS; VITRO;
D O I
10.2147/IJN.S77919
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Calcium silicate (CS) ceramic is a good coating candidate for biomedical implants to improve biocompatibility and accelerate early osseo-integration. However, the poor fracture toughness and wear resistance of this ceramic material restricts the long-term performance of implants. In this study, graphene plates (GPs) were used as reinforcement to improve the mechanical properties of CS coating. Composite coating containing 1.5 weight % GPs was prepared by vacuum plasma spraying technology. The good survival of the GPs in the composite coating was demonstrated by Raman analysis, although the defects of the GPs were increased after plasma spraying. Effects of the GPs' adoption on the microstructure of the coating were studied by scanning electron microscopy and transmission electron microscopy. Results showed that the GPs were homogenously distributed in the CS grains interface or enwrapped on the particles, and exhibited good wetting behavior with the CS matrix. The wear properties of the composite coating were obviously enhanced by the reinforcement of GPs. The reinforcement mechanism was attributed to the enhanced micro-hardness and interfacial bonding of the particles in the coating. In vivo experiments demonstrated that the composite coating possessed similarly good biocompatibility compared to pure CS coating. The bone-implant contact ratio reached 84.3% +/- 7.4% for GPs/CS coating and 79.6% +/- 9.4% for CS coating after 3 months' implantation.
引用
收藏
页码:3855 / 3863
页数:9
相关论文
共 50 条
  • [1] Hierarchical structure of biological systems A bioengineering approach
    Alcocer-Cuaron, Carlos
    Rivera, Ana L.
    Castano, Victor M.
    [J]. BIOENGINEERED, 2014, 5 (02) : 73 - 79
  • [2] Purification and structural annealing of multiwalled carbon nanotubes at graphitization temperatures
    Andrews, R
    Jacques, D
    Qian, D
    Dickey, EC
    [J]. CARBON, 2001, 39 (11) : 1681 - 1687
  • [3] The effect of cell behavior on plasma sprayed HA coatings with different post treatment
    Cao, Y
    Lin, Q
    Ying, XQ
    Pang, SJ
    Yang, BB
    Zhang, ZT
    Chen, JY
    Zhang, XD
    [J]. BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 705 - 708
  • [4] CARLISLE EM, 1986, CIBA F SYMP, V121, P123
  • [5] Annealing amorphous carbon nanotubes for their application in hydrogen storage
    Ci, LJ
    Zhu, HW
    Wei, BQ
    Xu, CL
    Wu, DH
    [J]. APPLIED SURFACE SCIENCE, 2003, 205 (1-4) : 39 - 43
  • [6] Annealing of template nanotubes to well-graphitized multi-walled carbon nanotubes
    Delpeux-Ouldriane, S
    Szostak, K
    Frackowiak, E
    Béguin, F
    [J]. CARBON, 2006, 44 (04) : 814 - 818
  • [7] Interpretation of Raman spectra of disordered and amorphous carbon
    Ferrari, AC
    Robertson, J
    [J]. PHYSICAL REVIEW B, 2000, 61 (20) : 14095 - 14107
  • [8] Raman spectroscopy of graphene and graphite: Disorder, electron-phonon coupling, doping and nonadiabatic effects
    Ferrari, Andrea C.
    [J]. SOLID STATE COMMUNICATIONS, 2007, 143 (1-2) : 47 - 57
  • [9] Histological studies of double layer HA/CaO-P2O5 glass plasma sprayed coatings using rabbit model
    Ferraz, MP
    Santos, JD
    Afonso, A
    Vasconcelos, M
    Monteiro, FJ
    [J]. BIOCERAMICS, 2000, 192-1 : 449 - 452
  • [10] Cellular chemotaxis induced by wear particles from joint replacements
    Goodman, Stuart B.
    Ma, Ting
    [J]. BIOMATERIALS, 2010, 31 (19) : 5045 - 5050