Ventilation and air conditioning system of deep-buried subway station in sub-tropical climates: Energy-saving strategies

被引:33
作者
Yin, Hua [1 ,2 ]
Yang, Caiyun [1 ,2 ]
Yi, Linzi [1 ,2 ]
Yu, Junyan [3 ]
Wu, Yingfeng [4 ]
Deng, Yujiao [5 ]
Tang, Zhihua [1 ,2 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Convers, Key Lab Renewable Energy, Guangzhou, Peoples R China
[2] Guangdong Key Lab New & Renewable Energy Res & De, 2 Nengyuan Rd, Guangzhou 510640, Peoples R China
[3] Guangzhou Metro Grp Co Ltd, Tower A,Wansheng Sq,1238 Xingang East Rd, Guangzhou 510330, Peoples R China
[4] Guangzhou Nikey Elect Co Ltd, Hitech Ind Dev Zone, Innovat Bldg C1,182 Sci Ave, Guangzhou 510665, Peoples R China
[5] Guangdong Ecol Meteorol Ctr, 312 Dongguanzhuang Rd, Guangzhou 510640, Peoples R China
关键词
Energy consumption; Energy audit; Energy-saving potential; VAC system; Subway station; CONSUMPTION; DESIGN; ENVIRONMENT; PERFORMANCE; MANAGEMENT; SIMULATION; CHINA; MODEL; FLOW;
D O I
10.1016/j.applthermaleng.2020.115555
中图分类号
O414.1 [热力学];
学科分类号
摘要
Subway systems are rapidly developing, and their energy consumption is considerably growing. The ventilation and air conditioning system in the subway station is the key energy-consuming system. It consumes a large amount of energy every day to provide a comfortable environment for passengers, and it has therefore received increasingly more attention from researchers worldwide. In this work, the variation law of the ventilation and air conditioning system of a subway station is analyzed from three aspects (energy consumption, load, and temperature) based on field test data, and the problems existing in the operation and management of the system are analyzed. For example, the results show that the total load of fresh air in the station was as high as 34-37%, and about 30 min was required to adjust the indoor temperature to a stable state. In addition, three general models and seven energy-saving strategies are put forward, and their energy saving potentials are estimated. After optimization, the ventilation and air conditioning system is found to reduce energy consumption by more than 30%. Not only are common problems that exist in the actual operation of the subway station ventilation and air conditioning system found in this research, but valuable measured data is also provided for the theoretical research of the thermal environment of the subway and the design of environmental control systems.
引用
收藏
页数:12
相关论文
共 24 条
[21]   Optimization on fresh outdoor air ratio of air conditioning system with stratum ventilation for both targeted indoor air quality and maximal energy saving [J].
Cheng, Yong ;
Zhang, Sheng ;
Huan, Chao ;
Oladokun, Majeed Olaide ;
Lin, Zhang .
BUILDING AND ENVIRONMENT, 2019, 147 :11-22
[22]   Deep learning-based fault diagnosis of variable refrigerant flow air-conditioning system for building energy saving [J].
Guo, Yabin ;
Tan, Zehan ;
Chen, Huanxin ;
Li, Guannan ;
Wang, Jiangyu ;
Huang, Ronggeng ;
Liu, Jiangyan ;
Ahmad, Tanveer .
APPLIED ENERGY, 2018, 225 :732-745
[23]   Energy-saving optimization of air-conditioning water system based on data-driven and improved parallel artificial immune system algorithm [J].
Yang, Siyuan ;
Yu, Junqi ;
Gao, Zhikun ;
Zhao, Anjun .
ENERGY CONVERSION AND MANAGEMENT, 2023, 283
[24]   Combining photovoltaic double-glazing curtain wall cooling and supply air reheating of an air-conditioning system: Energy-saving potential investigation [J].
Tang, Yayun ;
Ji, Jie ;
Wang, Chuyao ;
Xie, Hao ;
Ke, Wei .
ENERGY CONVERSION AND MANAGEMENT, 2022, 269