PET and parathyroid L-[carbon-11]methionine accumulation in hyperparathyroidism

被引:0
作者
Sundin, A
Johansson, C
Hellman, P
Bergstrom, M
Ahlstrom, H
Jacobson, GB
Langstrom, B
Rastad, J
机构
[1] UNIV UPPSALA,PET CTR,UPPSALA,SWEDEN
[2] DEPT DIAGNOST RADIOL,UPPSALA,SWEDEN
[3] DEPT SURG,UPPSALA,SWEDEN
关键词
PET; carbon-11-methionine; parathyroid gland; hyperparathyroidism;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study was designed to characterize L-[methyl-C-11]methionine accumulation in abnormal parathyroid tissues of hyperparathyroidism (HPT). Methods: Thirty-four patients with primary (n=32) or secondary HPT were investigated with PET before primary or reoperative (n=25) parathyroid surgery. Parathyroid C-11-methionine accumulation was analyzed for integrated uptake values in defined tissue volumes standardized for the injected dose and body weight (SUV), four contiguous pixels of maximal accumulation (SUVhs), SUV multiplied by area of region of interest (SUVr) and by the excised tissue weight (SUVw). Transport rate constants (slope, slope(hs)) were calculated according to Patlak's formula using plasma C-11 activity corrected for C-11-methionine metabolites. Results: True-positive localization was achieved in 85% of patients in whom 81% of the excised parathyroid lesions were visualized; no false-positive results were obtained, Corresponding proportions were 59% and 57% for CT and 55% and 52% for ultrasound, respectively. In the true-positive cases, parathyroid SUV, SUVhs and transport rate constants were consistently higher (p <0.01) than in the thyroid, pharynx-esophagus, neck muscle and apical lung. Parathyroid SUV, SUVhs and SUVr increased with intact serum parathyroid hormone and calcium values (p=0.0001-0.031), and weight of the excised tissue correlated with SUV and SUVhs (p=0.024, 0.044). Parathyroid SUVhs varied strongly with the transport rate constants (p=0.0008), and SUVr as well as s-calcium values differed significantly between parathyroid adenomas (n=11), chief cell hyperplasias(n=13), inadvertent implants (n=3) and parathyroid cancers (n=3). Conclusion: Carbon-11-methionine PET has potential application in preoperative localization and metabolic characterization of abnormal parathyroid tissues in human HPT.
引用
收藏
页码:1766 / 1770
页数:5
相关论文
共 50 条
  • [21] Carbon-11 epidepride:: A suitable radioligand for PET investigation of striatal and extrastriatal dopamine D2 receptors
    Langer, O
    Halldin, C
    Dollé, F
    Swahn, CG
    Olsson, H
    Karlsson, P
    Hall, H
    Sandell, J
    Lundkvist, C
    Vaufrey, F
    Loc'h, C
    Crouzel, C
    Mazière, B
    Farde, L
    NUCLEAR MEDICINE AND BIOLOGY, 1999, 26 (05) : 509 - 518
  • [22] Synthesis of new carbon-11 labeled benzoxazole derivatives for PET imaging of 5-HT3 receptor
    Gao, Mingzhang
    Wang, Min
    Hutchins, Gary D.
    Zheng, Qi-Huang
    EUROPEAN JOURNAL OF MEDICINAL CHEMISTRY, 2008, 43 (07) : 1570 - 1574
  • [23] Kinetic analysis of 2-[Carbon-11]thymidine PET imaging studies: Compartmental model and mathematical analysis
    Mankoff, DA
    Shields, AF
    Graham, MM
    Link, JM
    Eary, JF
    Krohn, KA
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (06) : 1043 - 1055
  • [24] Carbon-11 labeled papaverine as a PET tracer for imaging PDE10A: radiosynthesis, in vitro and in vivo evaluation
    Tu, Zhude
    Xu, Jinbin
    Jones, Lynne A.
    Li, Shihong
    Mach, Robert H.
    NUCLEAR MEDICINE AND BIOLOGY, 2010, 37 (04) : 509 - 516
  • [25] CARBON-11-METHIONINE AND FLUORINE-18-FDG PET STUDY IN BRAIN HEMATOMA
    DETHY, S
    GOLDMAN, S
    BLECIC, S
    LUXEN, A
    LEVIVIER, M
    HILDEBRAND, J
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (07) : 1162 - 1166
  • [26] Radiolabeling of the cannabinoid receptor agonist AZD1940 with carbon-11 and PET microdosing in non-human primate
    Schou, Magnus
    Varnas, Katarina
    Jucaite, Aurelija
    Gulyas, Balazs
    Halldin, Christer
    Farde, Lars
    NUCLEAR MEDICINE AND BIOLOGY, 2013, 40 (03) : 410 - 414
  • [27] Accuracy of parathyroid imaging: a comparison of planar scintigraphy, SPECT, SPECT-CT, and C-11 methionine PET for the detection of parathyroid adenomas and glandular hyperplasia
    Oeksuez, Mehmet Oezer
    Dittmann, Helmut
    Wicke, Corinna
    Muessig, Karsten
    Bares, Roland
    Pfannenberg, Christina
    Eschmann, Susanne Martina
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (04): : 297 - 307
  • [28] Development of [11C]/[3H-1]THK-5351-A potential novel carbon-11 tau imaging PET radioligand
    Stepanov, Vladimir
    Svedberg, Marie
    Jia, Zhisheng
    Krasikova, Raisa
    Lemoine, Laetitia
    Okamura, Nobujuki
    Furumoto, Shozo
    Mitsios, Nicholas
    Mulder, Jan
    Langstrom, Bengt
    Nordberg, Agneta
    Halldin, Christer
    NUCLEAR MEDICINE AND BIOLOGY, 2017, 46 : 50 - 53
  • [29] Enantioselective synthesis of carbon-11 labeled L-alanine using phase transfer catalysis of Schiff bases
    Filp, Ulrike
    Pekosak, Aleksandra
    Poot, Alex J.
    Windhorst, Albert D.
    TETRAHEDRON, 2016, 72 (41) : 6551 - 6557
  • [30] 11C-methionine PET/CT in 99mTc-sestamibi-negative hyperparathyroidism in patients with renal failure on chronic haemodialysis
    Rubello, D
    Fanti, S
    Nanni, C
    Farsad, M
    Castellucci, P
    Boschi, S
    Franchi, R
    Mariani, G
    Fig, LM
    Gross, MD
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (04) : 453 - 459