Pattern and degree of radiation exposure during endovascular surgery performed using a mobile C-arm or in a hybrid room

被引:5
|
作者
Quan, Cheng [1 ]
Lee, Sang Su [2 ]
机构
[1] Jilin Univ, Hosp 2, Dept Vasc Surg, Changchun, Jilin, Peoples R China
[2] Pusan Natl Univ, Dept Surg, Yangsan Hosp, Div Vasc & Endovasc Surg,Res Inst Convergence Bio, 20 Geumo Ro, Yangsan 50612, South Korea
关键词
Endovascular procedures; Surgeons; Operating rooms; Fluoroscopy; Radiation; DIAGNOSTIC CATHETERIZATION; INTERVENTIONAL CARDIOLOGY; STAFF; PATIENT; ANGIOPLASTY; DOSIMETRY; REPAIR; LEVEL;
D O I
10.4174/astr.2019.96.3.131
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: A prospective study was conducted to compare radiation exposure to different parts of an endovascular surgeon's body when using a mobile C-arm with that in a hybrid room. Methods: Exposure during individual procedures performed on 39 patients with a mobile C-arm and 42 patients in a hybrid room, from July 2016 to December 2016, was evaluated. Results: The procedures performed, fluoroscopy time, and dose-area product were not significantly different between groups. The dose-area product per second in the hybrid room group appeared greater than in the C-arm group (4.5 mu Gym(2)/ sec vs. 3.1 mu Gym(2)/sec). In the C-arm group, the peak skin dose on the right neck (1.77 mSv) and shoulder (1.48 mSv) appeared higher than those on their left side (0.32 mSv, 0.53 mSv, respectively) and the counterparts of the hybrid room group (0.88 mSv, 0.20 mSv, respectively). Conclusion: The peak skin dose in the hybrid room appeared highest for the lower part of the protective apron. The dose-area product per second seemed to be greater in the hybrid room than when using the C-arm. Thus, attention should be focused on protecting the surgeon's upper body when using the C-arm and the tower body when using the hybrid room.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 30 条
  • [1] RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY
    Cristante, Alexandre Fogaca
    Barbieri, Fabio
    Rodrigues da Silva, Almy Anacleto
    Dellamano, Jose Claudio
    ACTA ORTOPEDICA BRASILEIRA, 2019, 27 (01): : 46 - 49
  • [2] Evaluation of Radiation during EVAR Performed on a Mobile C-arm
    Maurel, B.
    Sobocinski, J.
    Perini, P.
    Guillou, M.
    Midulla, M.
    Azzaoui, R.
    Haulon, S.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (01) : 16 - 21
  • [3] Radiation exposure in hand surgery: Mini versus standard C-arm
    Athwal, GS
    Bueno, RA
    Wolfe, SW
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (06): : 1310 - 1316
  • [4] Comparison of Radiation Exposure from Fixed Table Fluoroscopy to a Portable C-Arm During Ureteroscopy
    Cabrera, Fernando J.
    Shin, Richard H.
    Waisanen, Kyle M.
    Nguyen, Giao
    Wang, Chu
    Scales, Charles D.
    Ferrandino, Michael N.
    Preminger, Glenn M.
    Yoshizumi, Terry T.
    Lipkin, Michael E.
    JOURNAL OF ENDOUROLOGY, 2017, 31 (09): : 835 - 840
  • [5] Staff dose evaluation by application of radiation protection during endoscopic retrograde cholangiopancreatography (ERCP) procedures performed with a mobile C-arm
    Osterlund, Andreas
    Drohn, Wilfried
    Hoedlmoser, Herbert
    Greiter, Matthias
    Schmid, Martin
    Kallman, Hans-Erik
    ACTA RADIOLOGICA, 2022, 63 (01) : 11 - 21
  • [6] Comparison of operator radiation exposure between C-arm and O-arm fluoroscopy for orthopaedic surgery
    Park, Moon Seok
    Lee, Kyoung Min
    Lee, Boram
    Min, Eunki
    Kim, Youhyun
    Jeon, Sungchae
    Huh, Young
    Lee, Kisung
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (04) : 431 - 438
  • [7] Radiation exposure caused by the OrthoScan mini C-arm in hand surgery: a one-year case series
    Hohendorff, Bernd
    Sauer, Henning
    Biber, Franz
    Franke, Joerg
    Mueller, Lars Peter
    Ries, Christian
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2019, 51 (03) : 177 - 184
  • [8] Radiation exposure of patients during mini C-arm use: an audit in 2032 procedures
    McCann, Mark R.
    Rust, Philippa A.
    Brown, Katie
    Lawrie, David
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (07) : 734 - 737
  • [9] Comparison of Radiation Exposure of AIRO Intraoperative CT with C-Arm Fluoroscopy during Posterior Lumbar Interbody Fusion
    Van Berkel, Brecht
    Smets, Gwendolien
    Van Schelverghem, Gertjan
    Houben, Elien
    Peuskens, Dieter
    Daenekindt, Thomas
    Buelens, Eveleen
    Weyns, Frank
    Nens, Joris
    Houben, Albrecht
    Van Cauter, Sofie
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [10] Direct Beam Radiation Exposure to Surgeons During Pinning of Supracondylar Humerus Fractures: Does C-Arm Position and the Attending Surgeon Matter?
    Eismann, Emily A.
    Wall, Eric J.
    Thomas, Elizabeth C.
    Little, Megan A.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2014, 34 (02) : 166 - 171