Objective: To compare the enhancement of brain metastasis between 3-dimensional fast spoiled gradient recalled acquisition in the steady state (3DFSPGR) and spin echo (SE) T1-weighted imaging at 3-T magnetic resonance imaging. Methods: The subjects comprised 18 patients with 81 suspected brain metastases. Axial SE and 3DFSPGR images were obtained before and after gadoteridol injection. The signal intensity of each tumor was measured for each sequence; the enhancement and contrast rates were also calculated. Results: For equivalent slice thicknesses, the enhancement and contrast rates of the 3DFSPGR images were lower than those of the SE images (<0.05), whereas for the thin slices, the rates were higher for the 3DFSPGR images (P < 0.01). Conclusions: On 3-T magnetic resonance imaging, the enhancement of 3DFSPGR images was less than that of the SE images under the same conditions, but not to a fatal degree, and thin slice 3DFSPGR imaging is therefore considered to be useful for detecting small lesions, when given a high dose of contrast agent and a suitable scanning delay time.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 21 条
  • [1] Akeson P, 1997, ACTA RADIOL, V38, P14
  • [2] Effect of contrast dose and field strength in the magnetic resonance detection of brain metastases
    Ba-Ssalamah, A
    Nöbauer-Huhmann, IM
    Pinker, K
    Schibany, N
    Prokesch, R
    Mehrain, S
    Mlynárik, V
    Fog, A
    Heimberger, K
    Trattnig, S
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (07) : 415 - 422
  • [3] CHAPPELL PM, 1994, AM J NEURORADIOL, V3, P7
  • [4] COMPARISON OF SPIN-ECHO T1-WEIGHTED AND FLASH-90-DEGREE GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING IN THE DETECTION OF CEREBRAL METASTASES
    CHERRYMAN, G
    GOLFIERI, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (753) : 712 - 715
  • [5] Duvvuri U, 1999, JMRI-J MAGN RESON IM, V10, P527, DOI 10.1002/(SICI)1522-2586(199910)10:4<527::AID-JMRI5>3.0.CO
  • [6] 2-0
  • [7] How much contrast is enough? Dependence of enhancement on field strength and MR pulse sequence
    Elster, AD
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (Suppl 5) : S276 - S280
  • [8] Optimizing intracranial metastasis detection for stereotactic radiosurgery
    Engh, Johnathan A.
    Flickinger, John C.
    Niranjan, Ajay
    Amin, Devin V.
    Kondziolka, Douglas S.
    Lunsford, L. Dade
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2007, 85 (04) : 162 - 168
  • [9] Efficacy of contrast medium use for neuroimaging at 3.0 T - Utility of IR-FSE compared to other T1-weighted pulse sequences
    Fischbach, F
    Bruhn, H
    Pech, M
    Neumann, F
    Ricke, J
    Felix, R
    Hofmann, KT
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (04) : 499 - 505
  • [10] Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
    Li, DB
    Haacke, EM
    Tarr, RW
    Venkatesan, R
    Lin, WL
    Wielopolski, P
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03): : 415 - 424