Simultaneously determination of multi metal elements in water samples by liquid cathode glow discharge-atomic emission spectrometry

被引:62
|
作者
Yu, Jie [1 ]
Yang, Shuxiu [1 ]
Sun, Duixiong [2 ,3 ]
Lu, Quanfang [1 ,3 ]
Zheng, Jidong [1 ]
Zhang, Xiaomei [1 ]
Wang, Xing [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Coll Phys & Elect Engn, Key Lab Atom & Mol Phys & Funct Mat Gansu Prov, Lanzhou 730070, Peoples R China
[3] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid cathode glow discharge (LCGD); Atomic emission spectrometry (AES); Determination; Metal elements; Water samples; TRACE HEAVY-METALS; ATMOSPHERIC-PRESSURE; ELECTROLYTE-SOLUTIONS; IMPROVED SENSITIVITY; EXCITATION SOURCE; FORMIC-ACID; PLASMA; SPECTROSCOPY; IMPROVEMENT; SURFACTANTS;
D O I
10.1016/j.microc.2016.05.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a liquid cathode glow discharge-atomic emission spectrometry (LCGD-AES) was constructed for simultaneously determination of K, Na, Ca, Mg and Zn in water samples (tap water, mineral water, Yellow River water and waste water), in which the glow discharge plasma was produced between the needle-like Pt anode and electrolyte around a quartz capillary cathode. The effects of the supporting electrolyte, discharge voltage and organic additives on emission intensity were investigated in detail. The limits of detections (LODs) of metals were compared with those measured by the closed-type electrolyte-cathode discharge-atomic emission spectrometry (ELCAD-AES). In addition, the measured results of water samples using LCGD-were verified by ICP. The results showed that the optimal operation conditions are pH = 1 HNO3 as supporting electrolyte, addition of 0.15% formic acid and 650 V discharge voltage. The R-2 and the RSD are ranged from 0.9887 to 0.9990 and 1.10% to 2.19%, respectively. LODs of K, Na, Ca, Mg and Zn are 0.02, 0.04, 0.19, 0.04 and 0.05 mg L-1, which are in agreement with the ELCAD-AES, and satisfied the recommended levels of the China standards for drinking water quality. The obtained results of Na, K, Ca, Mg and Zn in water samples by LCGD and ICP have certain difference. This result provides an alternative analytical method for the determination of metal elements in water samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:325 / 330
页数:6
相关论文
共 50 条
  • [11] Rapid determination of indium in water samples using a portable solution cathode glow discharge-atomic emission spectrometer
    Zu, Wenchuan
    Yang, Yin
    Wang, Yu
    Yang, Xiaotao
    Liu, Cong
    Ren, Min
    MICROCHEMICAL JOURNAL, 2018, 137 : 266 - 271
  • [12] Evaluation of analytical performance for the simultaneous detection of trace Cu, Co and Ni by using liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Sun, Duixiong
    Wang, Xing
    Zhu, Shuwen
    Zhang, Zhichao
    Yang, Wu
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 145 : 64 - 70
  • [13] Determination of Aqueous Potassium and Sodium Ions with Liquid-Phase Diaphragm Glow Discharge-Atomic Emission Spectrometry
    Liu Yong-jun
    Wang Lei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (09) : 2570 - 2573
  • [14] Enhanced Sensitivity for the Determination of Lithium by Miniaturized Liquid Cathode Glow Discharge (LCGD) Atomic Emission Spectrometry (AES) with the Addition of Surfactants
    Lu, Quanfang
    Feng, Yan
    Luo, Hui
    Yu, Jie
    Kang, Yuejing
    ANALYTICAL LETTERS, 2022, 55 (17) : 2789 - 2802
  • [15] Analytical Performance of Hollow Anode-Solution Cathode Glow Discharge-Atomic Emission Spectrometry
    Zheng, Peichao
    Li, Weiqi
    Wang, Jinmei
    Wang, Ningshen
    Zhong, Chao
    Luo, Yuanjiang
    Wang, Xiaofa
    Mao, Xuefeng
    Lai, Chunhong
    ANALYTICAL LETTERS, 2020, 53 (05) : 693 - 704
  • [16] Sensitive Determination of Alkali Metals by Liquid Anode Glow Discharge-Atomic Emission Spectrometry (LAGD-AES)
    Yu, Jie
    Wang, Kai
    Feng, Yan
    Hao, Xiaoxia
    Li, Xuehe
    Lu, Quanfang
    ANALYTICAL LETTERS, 2024,
  • [17] Ultratrace Pb determination in seawater by solution-cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Cheng, Junqi
    Li, Qing
    Zhao, Mingyue
    Wang, Zheng
    ANALYTICA CHIMICA ACTA, 2019, 1077 : 107 - 115
  • [18] Determination of gallium and indium by solution cathode glow discharge as an excitation source for atomic emission spectrometry
    Yu, Jie
    Kang, Yuejing
    Lu, Quanfang
    Luo, Hui
    Cui, Lijuan
    Lu, Zhuanhong
    Li, Juanlong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 172
  • [19] High-Sensitivity Determination of K, Ca, Na, and Mg in Salt Mines Samples by Atomic Emission Spectrometry with a Miniaturized Liquid Cathode Glow Discharge
    Yu, Jie
    Zhang, Zhichao
    Lu, Quanfang
    Sun, Duixiong
    Zhu, Shuwen
    Zhang, Xiaomin
    Wang, Xing
    Yang, Wu
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2017, 2017
  • [20] Elemental Analysis of Environmental Waters by Solution Cathode Glow Discharge-Atomic Emission Spectrometry (SCGD-AES) with a Multifunctional Injection System
    Zheng, Peichao
    Hu, Qiang
    Zhang, Hangxi
    Wang, Jinmei
    Yang, Yang
    He, Yuxin
    Wu, Meini
    Tian, Hongwu
    Dong, Daming
    Mao, Xuefeng
    Lai, Chunhong
    ANALYTICAL LETTERS, 2022, 55 (14) : 2273 - 2285