Percutaneous Endovascular Aortic Repair with Local Anesthesia - One Day Surgery

被引:8
作者
Sousa, Joel [1 ,2 ]
Brandao, Daniel [1 ]
Barreto, Paulo [1 ]
Ferreira, Joana [1 ]
Almeida-Lopes, Jose [1 ,2 ]
Mansilha, Armando [1 ,2 ]
机构
[1] Hosp CUF Porto, Serv Angiol & Cirurgia Vasc, Oporto, Portugal
[2] Univ Porto, Fac Med, Oporto, Portugal
关键词
Ambulatory Surgical Procedures; Aortic Aneurysm; Abdominal; Blood Vessel Prosthesis Implantation; Endovascular Procedures; ANEURYSM REPAIR; ACCESS; CLOSURE; DEVICE;
D O I
10.20344/amp.7715
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: To evaluate the results of the abdominal aortic aneurism endovascular treatment (EVAR), percutaneously and with local anesthesia, according to the concept of one day surgery. Material and Methods: Unicentric, retrospective analysis of patients with aorto-iliac aneurysmal disease, consecutively treated by EVAR with percutaneous access trough the Preclose technique (pEVAR), according to the outpatient criteria, with one overnight stay in the hospital. The technical success, exclusion of the aneurysmal sac, endoleak, re-intervention and mortality were evaluated. Results: Twenty consecutive patients (all male; mean age 74.65 years) were treated by EVAR with percutaneous access and local anesthesia, from which 95% (19) presented with abdominal aortic aneurysm and 5% (1) common iliac aneurysm. All implants were sucessfully performed, with an initial endoleak rate of 10% (2), determined by one type 1a endoleak successfully corrected intra-operatively and one type 2a endoleak diagnosed in the first imaging control, which sealed spontaneously on the second control. Initial technical success for percutaneous closure was 97.5%, with one case reported of femoral pseudo-aneurism, posteriorly treated by percutaneous thrombin injection. Median length of stay was one day [1-10], with a mean follow-up of 11.4 months [1-36]. Both the re-intervention and mortality rate are 0% for the selected period. Conclusion: Our one day surgery model for the outpatient treatment of abdominal aortic aneurysm by the pEVAR technique is innovative, safe and effective, as long as the selection criteria are respected.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 27 条
[1]   Selective Use of Percutaneous Endovascular Aneurysm Repair in Women Leads to Fewer Groin Complications [J].
Al-Khatib, Weesam K. ;
Zayed, Mohamed A. ;
Harris, E. John ;
Dalman, Ronald L. ;
Lee, Jason T. .
ANNALS OF VASCULAR SURGERY, 2012, 26 (04) :476-482
[2]   Selection, Thirty Day Outcome and Costs for Short Stay Endovascular Aortic Aneurysm Repair (SEVAR) [J].
Al-Zuhir, N. ;
Wong, J. ;
Nammuni, I. ;
Curran, G. ;
Tang, T. ;
Varty, K. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (06) :662-665
[3]   Predicting the learning curve and failures of total percutaneous endovascular aortic aneurysm repair [J].
Bechara, Carlos F. ;
Barshes, Neal R. ;
Pisimisis, George ;
Chen, Huiting ;
Pak, Taemee ;
Lin, Peter H. ;
Kougias, Panagiotis .
JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) :72-76
[4]   Ultrasound-guided percutaneous endovascular aneurysm repair success is predicted by access vessel diameter [J].
Bensley, Rodney P. ;
Hurks, Rob ;
Huang, Zhen ;
Pomposelli, Frank ;
Hamdan, Allen ;
Wyers, Mark ;
Chaikof, Elliot ;
Schermerhorn, Marc L. .
JOURNAL OF VASCULAR SURGERY, 2012, 55 (06) :1554-1561
[5]  
Dosluogiu HH, 2007, J ENDOVASC THER, V14, P184, DOI 10.1583/1545-1550(2007)14[184:TPEROA]2.0.CO
[6]  
2
[7]   Ambulatory percutaneous endovascular abdominal aortic aneurysm repair [J].
Dosluoglu, Hasan H. ;
Lall, Purandath ;
Blochle, Raphael ;
Harris, Linda M. ;
Dryjski, Maciej L. .
JOURNAL OF VASCULAR SURGERY, 2014, 59 (01) :58-64
[8]   Epidemiology of aortic aneurysm repair in the United States from 2000 to 2010 [J].
Dua, Anahita ;
Kuy, SreyRam ;
Lee, Cheong J. ;
Upchurch, Gilbert R., Jr. ;
Desai, Sapan S. .
JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) :1512-1517
[9]  
Gupta Rajan K, 2010, Semin Intervent Radiol, V27, P348, DOI 10.1055/s-0030-1267860
[10]  
Haas PC, 1999, J ENDOVASC SURG, V6, P168, DOI 10.1583/1074-6218(1999)006<0168:COLPAS>2.0.CO