Bioprosthetic tissue valves are increasingly utilized during surgical aortic valve replacement. These valves have limited durability and many fail with time, resulting in stenosis, regurgitation, or both. Repeat cardiac surgery has been the standard of care for patients with failed bioprostheses. Transcatheter valve implantation inside failed surgically implanted bioprostheses (valve-in-valve) is a new less invasive alternative to repeat surgery. We review the potential and challenges of valve-in-valve implantation in patients with failing surgical aortic bioprostheses.
引用
收藏
页码:695 / 703
页数:9
相关论文
共 53 条
[1]   Valve-in-Valve Hemodynamics of 20-mm Transcatheter Aortic Valves in Small Bioprostheses [J].
Azadani, Ali N. ;
Jaussaud, Nicolas ;
Ge, Liang ;
Chitsaz, Sam ;
Chuter, Timothy A. M. ;
Tseng, Elaine E. .
ANNALS OF THORACIC SURGERY, 2011, 92 (02) :548-555
[2]   Transcatheter valve-in-valve implantation for failing bioprosthetic valves [J].
Azadani, Ali N. ;
Tseng, Elaine E. .
FUTURE CARDIOLOGY, 2010, 6 (06) :811-831
[3]   Transcatheter aortic valves inadequately relieve stenosis in small degenerated bioprostheses [J].
Azadani, Ali N. ;
Jaussaud, Nicolas ;
Matthews, Peter B. ;
Ge, Liang ;
Chuter, Timothy A. M. ;
Tseng, Elaine E. .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 11 (01) :70-77
[4]   A guide to fluoroscopic identification and design of bioprosthetic valves: A reference for valve-in-valve procedure [J].
Bapat, Vinayak ;
Mydin, Izanne ;
Chadalavada, Sucharitha ;
Tehrani, Hassan ;
Attia, Rizwan ;
Thomas, Martyn .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) :853-861
[5]   Transcatheter Valve-in-Valve Implantation Using Core Valve Revalving System for Failed Surgical Aortic Bioprostheses [J].
Bedogni, Francesco ;
Laudisa, Maria Luisa ;
Pizzocri, Samuele ;
Tamburino, Corrado ;
Ussia, Gian Paolo ;
Petronio, Anna Sonia ;
Napodano, Massimo ;
Ramondo, Angelo ;
Presbitero, Patrizia ;
Ettori, Federica ;
Santoro, Gennaro ;
Klugman, Silvio ;
De Marco, Federico ;
Brambilla, Nedy ;
Testa, Luca .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) :1228-1234
[6]  
Bonow Robert O, 2008, Circulation, V118, pe523, DOI 10.1161/CIRCULATIONAHA.108.190748
[7]   New insights in minimally invasive valve replacement: description of a cooperative approach for the off-pump replacement of mitral valves [J].
Boudjemline, Y ;
Pineau, E ;
Borenstein, N ;
Behr, L ;
Bonhoeffer, P .
EUROPEAN HEART JOURNAL, 2005, 26 (19) :2013-2017
[8]   Long-Term Safety and Effectiveness of Mechanical Versus Biologic Aortic Valve Prostheses in Older Patients Results From the Society of Thoracic Surgeons Adult Cardiac Surgery National Database [J].
Brennan, J. Matthew ;
Edwards, Fred H. ;
Zhao, Yue ;
O'Brien, Sean ;
Booth, Michael E. ;
Dokholyan, Rachel S. ;
Douglas, Pamela S. ;
Peterson, Eric D. .
CIRCULATION, 2013, 127 (16) :1647-+
[9]   Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: Changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database [J].
Brown, James M. ;
O'Brien, Sean M. ;
Wu, Changfu ;
Sikora, Jo Ann H. ;
Griffith, Bartley P. ;
Gammie, James S. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :82-90
[10]   5-Year Experience With Transcatheter Transapical Mitral Valve-in-Valve Implantation for Bioprosthetic Valve Dysfunction [J].
Cheung, Anson ;
Webb, John G. ;
Barbanti, Marco ;
Freeman, Melanie ;
Binder, Ronald K. ;
Thompson, Christopher ;
Wood, David A. ;
Ye, Jian .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (17) :1759-1766