Heads-up 3D eye surgery: Safety outcomes and technological review after 2 years of day-to-day use

被引:20
作者
Del Turco, Claudia [1 ]
D'Amico Ricci, Giuseppe [2 ]
Dal Vecchio, Marco [2 ]
Bogetto, Caterina [1 ]
Panico, Edoardo [3 ]
Giobbio, Dora Cecilia [1 ]
Romano, Mario R. [4 ]
Panico, Claudio [1 ]
La Spina, Carlo [1 ]
机构
[1] Humanitas Gradenigo Hosp, Eye Clin, Corso Regina Margherita 10, I-10100 Turin, Italy
[2] ASL Citta Torino, Turin Eye Hosp, UO Oculist 2, Turin, Italy
[3] Univ Torino, Fac Med Chirurgia, Turin, Italy
[4] Humanitas Univ, Humanitas Gavazzeni Hosp, Eye Unit, Bergamo, Italy
关键词
Scleral buckling; cornea; external disease; surgical trauma; glaucoma incisional surgery; glaucoma; phacoemulsification; lens; cataract; surgical instruments; special techniques; eyelid disease; cosmetic eyelid and facial surgery; oculoplastic eyelid; lacrimal disease; strabismus surgery; complications; strabismus; trauma; pars plana vitrectomy; vitreous; endophthalmitis; retinal detachment; retina;
D O I
10.1177/11206721211012856
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: 3D heads-up visualization systems are aimed to improve the surgical experience by providing high-resolution imaging. Objective of our study is to analyze, over a long-time span, the grade of satisfaction and safety of day-to-day 3D surgery compared to standard surgery and to investigate the technical distinctiveness between the heads-up systems currently in use. Methods: In this retrospective observational case series. we reviewed all surgical records of our ophthalmology-dedicated operatory rooms since the arrival of 3D heads-up viewing system, in November 2017. In particular, we compared the procedural complications of 3D-equipped operatory room (3DR) with the standard microscope operatory room (2DR). Moreover, a satisfaction questionnaire was administered to those surgeons shifting on both rooms to test their preferences on seven specific parameters (comfort, visibility, image quality, depth perception, simplicity of use, maneuverability and teaching potential). Results: 5483 eye surgeries were considered. 2777 (50.6%) were performed in 3DR and 2706 (49.3%) in 2DR. Procedural complication rate was comparable in 3DR and 2DR, also when considering different subtypes of surgery. Twelve surgeons (100% of our surgery team) participated in our satisfaction survey, expressing highest satisfaction score for 3D when applied in retina surgery. For cataract surgery, 3D scored best in all the parameters except for facility in use and depth of field perception. Conclusion: Long-term day-to-day use of 3D heads-up visualization systems showed its safety and its outstanding teaching potential in all ophthalmic surgical subtypes, with higher surgeons confidence for retina and cataract surgery.
引用
收藏
页码:1129 / 1135
页数:7
相关论文
共 16 条
  • [1] The Scope Of Three-Dimensional Digital Visualization Systems In Vitreoretinal Surgery
    Agranat, Joshua S.
    Miller, John B.
    Douglas, Vivian Paraskevi
    Douglas, Konstantinos A. A.
    Marmalidou, Anna
    Cunningham, Matthew A.
    Houston, Samuel K., III
    [J]. CLINICAL OPHTHALMOLOGY, 2019, 13 : 2093 - 2096
  • [2] Comparing Heads-Up versus Binocular Microscope Visualization Systems in Anterior and Posterior Segment Surgeries: A Retrospective Study
    Berquet, Florence
    Henry, Adrien
    Barbe, Coralie
    Cheny, Thibault
    Afriat, Mickael
    Benyelles, Abdel-Karim
    Bartolomeu, David
    Arndt, Carl
    [J]. OPHTHALMOLOGICA, 2020, 243 (05) : 347 - 354
  • [3] Charles S., 2017, RETINA TODAY, V12, P48
  • [4] Heads-up 3D vision system for retinal detachment surgery
    Michele Coppola
    Carlo La Spina
    Alessandro Rabiolo
    Giuseppe Querques
    Francesco Bandello
    [J]. International Journal of Retina and Vitreous, 3 (1)
  • [5] Dr. Claus Eckardt performs retina surgery "heads-up" without microscope oculars [press release], 2014, TRUEVISION SYSTEMS
  • [6] HEADS-UP SURGERY FOR VITREORETINAL PROCEDURES An Experimental and Clinical Study
    Eckardt, Claus
    Paulo, Erica B.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (01): : 137 - 147
  • [7] Galvis V, 2017, J SURG CASE REP, DOI 10.1093/jscr/rjx231
  • [8] Hamasaki I, 2019, ACTA MED OKAYAMA, V73, P229, DOI 10.18926/AMO/56865
  • [9] Comparison of clinical outcomes between "heads-up" 3D viewing system and conventional microscope in macular hole surgeries: A pilot study
    Kumar, Atul
    Hasan, Nasiq
    Kakkar, Prateek
    Mutha, Vineet
    Karthikeya, R.
    Sundar, Dheepak
    Ravani, Raghav
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (12) : 1816 - 1819
  • [10] First experience of nDASEK with heads-up surgery A case report
    Mohamed, Yasser Helmy
    Uematsu, Masafumi
    Inoue, Daisuke
    Kitaoka, Takashi
    [J]. MEDICINE, 2017, 96 (19)