Six-Month Long In Vitro Degradation Tests of Biodegradable Twinning-Induced Plasticity Steels Alloyed with Ag for Stent Applications

被引:13
作者
Loffredo, Sergio [1 ,2 ]
Gambaro, Sofia [1 ,3 ]
de Andrade, Leticia Marin [1 ]
Paternoster, Carlo [1 ]
Casati, Riccardo [2 ]
Giguere, Nicolas [4 ]
Vedani, Maurizio [2 ]
Mantovani, Diego [1 ]
机构
[1] Laval Univ, CHU Quebec, Res Ctr,Canada Res Chair Biomat & Bioengn Innovat, Div Regenerat Med,Dept Min Met Mat Engn,Lab Bioma, Quebec City, PQ G1V 0A6, Canada
[2] Politecn Milan, Dept Mech Engn, I-20156 Milan, Italy
[3] CNR, Inst Condensed Matter Chem & Technol Energy CNR I, I-16149 Genoa, Italy
[4] Quebec Met Ctr CMQ, Trois Rivieres, PQ G9A 5E1, Canada
关键词
biodegradable metals; twinning-induced plasticity; steels; corrosion; silver; degradation mechanism; ABSORBABLE METAL SCAFFOLD; FE-BASED ALLOYS; PURE IRON; BIOSOLVE-II; CORROSION PROPERTIES; PROTEIN ADSORPTION; PERFORMANCE; BEHAVIOR; VIVO; CYTOCOMPATIBILITY;
D O I
10.1021/acsbiomaterials.1c00365
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Twinning-induced plasticity (TWIP) Fe-Mn-C steels are biodegradable metals with far superior mechanical properties to any biodegradable metal, including Mg alloys, used in commercially available devices. For this reason, the use of Fe-Mn-C alloys to produce thinner and thinner implants can be exploited for overcoming the device size limitations that biodegradable stents still present. However, Fe-Mn steels are known to form a phosphate layer on their surface over long implantation times in animals, preventing device degradation in the required timeframe. The introduction of second phases in such alloys to promote galvanic coupling showed a short-term promise, and particularly the use of Ag looked especially effective. Nonetheless, the evolution of the corrosion mechanism of quaternary Fe-Mn-C-Ag alloys over time is still unknown. This study aims at understanding how corrosion changes over time for a TWIP steel alloyed with Ag using a simple static immersion setup. The presence of Ag promoted some galvanic coupling just in the first week of immersion; this effect was then suppressed by the formation of a mixed carbonate/hydroxide layer. This layer partly detached after 2 months and was replaced by a stable phosphate layer, over which a new carbonate/hydroxide formed after 4 months, effectively hindering the sample degradation. Attachment of phosphates to the surface matches 1-year outcomes from animal tests reported by other authors, but this phenomenon cannot be predicted using immersion up to 28 days. These results demonstrate that immersion tests of Fe-based degradable alloys can be related to animal tests only when they are carried out for a sufficiently long time and that galvanic coupling with Ag is not a viable strategy in the long term. Future works should focus more on surface modifications to control the interfacial behavior rather than alloying in the bulk.
引用
收藏
页码:3669 / 3682
页数:14
相关论文
共 49 条
[1]   A complete study of amorphous iron phosphate structure [J].
Al-Hasni, Bushra M. ;
Mountjoy, Gavin ;
Barney, Emma .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2013, 380 :141-152
[2]   QUALX:: a computer program for qualitative analysis using powder diffraction data [J].
Altomare, Angela ;
Cuocci, Corrado ;
Giacovazzo, Carmelo ;
Moliterni, Anna ;
Rizzi, Rosanna .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2008, 41 :815-817
[3]  
[Anonymous], 2016, STANDARD TEST METHOD, P1, DOI DOI 10.1520/F3184-16
[4]   In Vitro Degradation, Hemocompatibility, and Cytocompatibility of Nanostructured Absorbable Fe-Mn-Ag Alloys for Biomedical Application [J].
Bagha, Pedram Sotoudeh ;
Khakbiz, Mehrdad ;
Sheibani, Saeed ;
Ebrahimi-Barough, Somayeh ;
Hermawan, Hendra .
ACS BIOMATERIALS SCIENCE & ENGINEERING, 2020, 6 (04) :2094-2106
[5]   Design and characterization of nano and bimodal structured biodegradable Fe-Mn-Ag alloy with accelerated corrosion rate [J].
Bagha, Pedram Sotoudeh ;
Khakbiz, Mehrdad ;
Sheibani, Saeed ;
Hermawan, Hendra .
JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 767 :955-965
[6]   The effect of alloying elements on the properties of pressed and non-pressed biodegradable Fe-Mn-Ag powder metallurgy alloys [J].
Conti, Malcolm Caligari ;
Mallia, Bertram ;
Sinagra, Emmanuel ;
Wismayer, Pierre Schembri ;
Buhagiar, Joseph ;
Vella, Daniel .
HELIYON, 2019, 5 (09)
[7]   Influence of cold rolling on in vitro cytotoxicity and electrochemical behaviour of an Fe-Mn-C biodegradable alloy in physiological solutions [J].
Conti, Malcolm Caligari ;
Aquilina, Daniel ;
Paternoster, Carlo ;
Vella, Daniel ;
Sinagra, Emmanuel ;
Mantovani, Diego ;
Cassar, Glenn ;
Wismayer, Pierre Schembri ;
Buhagiar, Joseph .
HELIYON, 2018, 4 (11)
[8]   In vitro and in vivo corrosion properties of new iron-manganese alloys designed for cardiovascular applications [J].
Drynda, Andreas ;
Hassel, Thomas ;
Bach, Friedrich Wilhelm ;
Peuster, Matthias .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (03) :649-660
[9]   Cytotoxicity of corrosion products of degradable Fe-based stents: Relevance of pH and insoluble products [J].
Fagali, Natalia S. ;
Grillo, Claudia A. ;
Puntarulo, Susana ;
Fernandez Lorenzo de Mele, Monica A. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2015, 128 :480-488
[10]   Iron and iron-based alloys for temporary cardiovascular applications [J].
Francis, A. ;
Yang, Y. ;
Virtanen, S. ;
Boccaccini, A. R. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2015, 26 (03) :1-16