Perfusion weighted imaging using combined gradient/spin echo EPIK: Brain tumour applications in hybrid MR-PET

被引:4
作者
Shah, N. Jon [1 ,2 ,3 ,4 ]
da Silva, Nuno Andre [1 ]
Yun, Seong Dae [1 ]
机构
[1] Forschungszentrum Julich, Inst Neurosci & Med 4, Med Imaging Phys, D-52425 Julich, Germany
[2] Forschungszentrum Julich, Inst Neurosci 11, Mol Neurosci & Neuroimaging, Julich, Germany
[3] Rhein Westfal TH Aachen, Fac Med, Dept Neurol, JARA, Aachen, Germany
[4] Monash Univ, Sch Psychol Sci, Monash Biomed Imaging, Melbourne, Vic, Australia
关键词
EPIK; gradient echo; spin echo; image distortion; MR-PET; multi-contrast; ARTERIAL INPUT FUNCTION; CEREBRAL BLOOD-VOLUME; SUSCEPTIBILITY CONTRAST MRI; DSC-MRI; DCE-MRI; SPIN; SIZE; ACQUISITION; QUANTIFICATION; ACCELERATION;
D O I
10.1002/hbm.24537
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Advanced perfusion-weighted imaging (PWI) methods that combine gradient echo (GE) and spin echo (SE) data are important tools for the study of brain tumours. In PWI, single-shot, EPI-based methods have been widely used due to their relatively high imaging speed. However, when used with increasing spatial resolution, single-shot EPI methods often show limitations in whole-brain coverage for multi-contrast applications. To overcome this limitation, this work employs a new version of EPI with keyhole (EPIK) to provide five echoes: two with GEs, two with mixed GESE and one with SE; the sequence is termed "GESE-EPIK." The performance of GESE-EPIK is evaluated against its nearest relative, EPI, in terms of the temporal signal-to-noise ratio (tSNR). Here, data from brain tumour patients were acquired using a hybrid 3T MR-BrainPET scanner. GESE-EPIK resulted in reduced susceptibility artefacts, shorter TEs for the five echoes and increased brain coverage when compared to EPI. Moreover, compared to EPI, EPIK achieved a comparable tSNR for the first and second echoes and significantly higher tSNR for other echoes. A new method to obtain multi-echo GE and SE data with shorter TEs and increased brain coverage is demonstrated. As proposed here, the workflow can be shortened and the integration of multimodal clinical MR-PET studies can be facilitated.
引用
收藏
页码:4144 / 4154
页数:11
相关论文
共 26 条
  • [1] Combined spin- and gradient-echo perfusion-weighted imaging
    Schmiedeskamp, Heiko
    Straka, Matus
    Newbould, Rexford D.
    Zaharchuk, Greg
    Andre, Jalal B.
    Olivot, Jean-Marc
    Moseley, Michael E.
    Albers, Gregory W.
    Bammer, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 30 - 40
  • [2] A Simplified Spin and Gradient Echo Approach for Brain Tumor Perfusion Imaging
    Stokes, Ashley M.
    Quarles, C. Chad
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) : 356 - 362
  • [3] From simultaneous to synergistic MR-PET brain imaging: A review of hybrid MR-PET imaging methodologies
    Chen, Zhaolin
    Jamadar, Sharna D.
    Li, Shenpeng
    Sforazzini, Francesco
    Baran, Jakub
    Ferris, Nicholas
    Shah, Nadim Jon
    Egan, Gary F.
    HUMAN BRAIN MAPPING, 2018, 39 (12) : 5126 - 5144
  • [4] Simultaneous perfusion and permeability measurements using combined spin- and gradient-echo MRI
    Schmiedeskamp, Heiko
    Andre, Jalal B.
    Straka, Matus
    Christen, Thomas
    Nagpal, Seema
    Recht, Lawrence
    Thomas, Reena P.
    Zaharchuk, Greg
    Bammer, Roland
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2013, 33 (05) : 732 - 743
  • [5] Comparison of 18F-FET PET and Perfusion-Weighted MR Imaging: A PET/MR Imaging Hybrid Study in Patients with Brain Tumors
    Filss, Christian P.
    Galldiks, Norbert
    Stoffels, Gabriele
    Sabel, Michael
    Wittsack, Hans J.
    Turowski, Bernd
    Antoch, Gerald
    Zhang, Ke
    Fink, Gereon R.
    Coenen, Heinz H.
    Shah, Nadim J.
    Herzog, Hans
    Langen, Karl-Josef
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (04) : 540 - 545
  • [6] Assessment of a simplified spin and gradient echo (sSAGE) approach for human brain tumor perfusion imaging
    Stokes, Ashley M.
    Skinner, Jack T.
    Yankeelov, Thomas
    Quarles, C. Chad
    MAGNETIC RESONANCE IMAGING, 2016, 34 (09) : 1248 - 1255
  • [7] Evaluation of a multiple spin- and gradient-echo (SAGE) EPI acquisition with SENSE acceleration: Applications for perfusion imaging in and outside the brain
    Skinner, Jack T.
    Robison, Ryan K.
    Elder, Christopher P.
    Newton, Allen T.
    Damon, Bruce M.
    Quarles, C. Chad
    MAGNETIC RESONANCE IMAGING, 2014, 32 (10) : 1171 - 1180
  • [8] MR-PET co-registration in upper abdominal imaging: quantitative comparison of two different T1-weighted gradient echo sequences: initial observations
    Ramalho, Miguel
    AlObaidy, Mamdoh
    Burke, Lauren M.
    Dale, Brian M.
    Busireddy, Kiran K.
    Wong, Terence Z.
    AlSugair, Abdulaziz
    Semelka, Richard C.
    ABDOMINAL IMAGING, 2015, 40 (06): : 1426 - 1431
  • [9] ?Synthetic? DSC Perfusion MRI with Adjustable Acquisition Parameters in Brain Tumors Using Dynamic Spin-and-Gradient-Echo Echoplanar Imaging
    Sanvito, Francesco
    Yao, Jingwen
    Cho, Nicholas S.
    Raymond, Catalina
    Telesca, Donatello
    Pope, Whitney B.
    Everson, Richard G.
    Salamon, Noriko
    Boxerman, Jerrold L.
    Cloughesy, Timothy F.
    Ellingson, Benjamin M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025, : 311 - 320
  • [10] Clinical applications of dynamic susceptibility contrast perfusion-weighted MR imaging in brain tumours
    Romano, A.
    Espagnet, M. C. Rossi
    Calabria, L. F.
    Coppola, V.
    Talamanca, L. Figa
    Cipriani, V.
    Minniti, G.
    Pierallini, A.
    Fantozzi, L. M.
    Bozzao, A.
    RADIOLOGIA MEDICA, 2012, 117 (03): : 445 - 460