Automatic control of a laboratory flotation column

被引:30
|
作者
Del Villar, R [1 ]
Grégoire, M
Pomerleau, A
机构
[1] Univ Laval, Dept Min & Met, GRAIIM, St Foy, PQ G1K 7P4, Canada
[2] Univ Laval, Dept Elect Engn, St Foy, PQ G1K 7P4, Canada
关键词
column flotation; neural networks; process control; process optimisation; mineral processing;
D O I
10.1016/S0892-6875(99)00007-2
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The operation of industrial flotation columns requires the control of at least two variables, the interface position and the bias rate, by manipulation of some appropriate operating variables. Problems arise due to the reliability of existing methods of measuring the bias (i.e bias = tailings water - feed water), a situation which has often forced the industry to disregard this control loop. Moreover, when using such a measuring approach, the identification of the process dynamics is impossible. A second problem arises from the possible interaction between both control loops that might call for the use of a more complex multivariable control strategy. Recent work done at Laval University has demonstrated the feasibility of an independent sensor for bias, which models the relation between the conductivity profile across the interface and the bias value using a neural network algorithm. A 250 cm height, 5.25 cm diameter Plexiglas laboratory column was equipped with a series of conductivity electrodes in its uppermost part (across the interface) to measure both interface position and bias rate. Using such equipment, the flotation column dynamics was identified. The results thus obtained permitted the design and implementation of a distributed PI control strategy, where bias was associated to wash water rate and froth depth to tails rate. Both PI controllers were tuned using a frequency-response tuning method. Results of both identification and process control are presented and discussed. (C) 1999 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:291 / 308
页数:18
相关论文
共 50 条
  • [41] A study of the rejects recovery in a column flotation
    Oliveira, MS
    Cioqueta, DR
    Sallum, M
    Miro, R
    Guimaraes, RC
    Ataíde, CH
    Barrozo, MAS
    ADVANCED POWDER TECHNOLOGY IV, 2005, 498-499 : 278 - 284
  • [42] Fine coal beneficiation by column flotation
    Han, Oh-Hyung
    Kim, Min-Kyu
    Kim, Byoung-Gon
    Subasinghe, Nimal
    Park, Chul-Hyun
    FUEL PROCESSING TECHNOLOGY, 2014, 126 : 49 - 59
  • [43] Flotation column automation: state of the art
    Bergh, LG
    Yianatos, JB
    CONTROL ENGINEERING PRACTICE, 2003, 11 (01) : 67 - 72
  • [44] Recent advances in bias and froth depth control in flotation columns
    Bouchard, J
    Desbiens, A
    del Villar, R
    MINERALS ENGINEERING, 2005, 18 (07) : 709 - 720
  • [45] DEVELOPMENT OF A SYSTEM FOR BUBBLE SIZE MEASUREMENT, MONITORING AND CONTROL IN A BENCH SCALE COLUMN FLOTATION
    Oliveira, C.
    Pompeo, A. A.
    Seger, M. A.
    Rodrigues, R. T.
    HOLOS, 2015, 31 (07) : 80 - 87
  • [46] COLUMN FLOTATION - A SELECTED REVIEW .4. NOVEL FLOTATION DEVICES
    FINCH, JA
    MINERALS ENGINEERING, 1995, 8 (06) : 587 - 602
  • [47] Assessment of pH-responsive nanoparticles performance on laboratory column flotation cell applying a real ore feed
    Nasirimoghaddam, Samiramis
    Mohebbi, Ali
    Karimi, Mohsen
    Yarahmadi, M. Reza
    INTERNATIONAL JOURNAL OF MINING SCIENCE AND TECHNOLOGY, 2020, 30 (02) : 197 - 205
  • [48] Assessment of pH-responsive nanoparticles performance on laboratory column flotation cell applying a real ore feed
    Samiramis Nasirimoghaddam
    Ali Mohebbi
    Mohsen Karimi
    M.Reza Yarahmadi
    International Journal of Mining Science and Technology, 2020, 30 (02) : 197 - 205
  • [50] Study on bubble characteristics of flotation column in hematite reverse cationic flotation process
    Wang, Weizhi
    Han, Jikang
    PHYSICOCHEMICAL PROBLEMS OF MINERAL PROCESSING, 2020, 56 (01): : 64 - 75