A pyrrole quinoline quinone glucose dehydrogenase biosensor based on screen-printed carbon paste electrodes modified by carbon nanotubes

被引:56
作者
Li, Guang [1 ]
Xu, Hui [1 ]
Huang, Wenjun [1 ]
Wang, You [1 ]
Wu, Yesi [2 ]
Parajuli, Rabindra
机构
[1] Zhejiang Univ, Inst Adv Proc Control, State Key Lab Ind Control Technol, Hangzhou 310027, Peoples R China
[2] Hangzhou Bravo Technol Co Ltd, Hangzhou 310020, Zhejiang, Peoples R China
关键词
pyrrole quinoline quinone glucose dehydrogenase; carbon nanotubes; biosensor; electron transfer;
D O I
10.1088/0957-0233/19/6/065203
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A carbon nanotube (CNT) modified biosensor based on oxygen-independent, pyrrole quinoline quinone glucose dehydrogenase (PQQ-GDH) for monitoring glucose was studied. The disposable amperometric biosensors based on screen-printed carbon paste electrodes are low cost and suitable for mass production. Potassium ferricyanide was immobilized on the surface of the electrodes as an electron mediator, which decreased the work potential. The biosensor showed a linear amperometric response to glucose from 1 to 35 mM, with a sensitivity of 31.0 mu A mM(-1) cm(-2). Experimentally, the compositions of PQQ-GDH, potassium ferricyanide, CNTs and other components were evaluated and optimized. Only 2 mu l of sample are needed for one test, and the response time of the sensor is 20 s. The characteristics of the biosensor were studied through cyclic voltammetry, and experimental results showed that the CNTs could facilitate the electron transfer between the enzyme and electrode surface significantly. Compared with the biosensor without carbon nanotube modification, the CNTs improved the sensitivity of the biosensor up to five times.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Malate quinone oxidoreductase biosensors based on tetrathiafulvalene and gold nanoparticles modified screen-printed carbon electrodes for malic acid determination in wine
    Molinero-Abad, Begona
    Asuncion Alonso-Lomillo, M.
    Dominguez-Renedo, Olga
    Arcos-Martinez, M. Julia
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 971 - 975
  • [22] Screen-printed carbon electrodes modified with cellobiose dehydrogenase: Amplification factor for catechol vs. reversibility of ferricyanide
    Dock, E
    Ruzgas, T
    ELECTROANALYSIS, 2003, 15 (5-6) : 492 - 498
  • [23] An electrochemical ELISA-like immunosensor for miRNAs detection based on screen-printed gold electrodes modified with reduced graphene oxide and carbon nanotubes
    Tran, H. V.
    Piro, B.
    Reisberg, S.
    Huy Nguyen, L.
    Dung Nguyen, T.
    Duc, H. T.
    Pham, M. C.
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 25 - 30
  • [24] Development of single-wall carbon nanotubes modified screen-printed electrode using a ferrocene-modified cationic surfactant for amperometric glucose biosensor applications
    Sato, Naruhide
    Okuma, Hirokazu
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) : 188 - 194
  • [25] Carbon Nanomaterials-Based Screen-Printed Electrodes for Sensing Applications
    Silva, Rafael Matias
    da Silva, Alexsandra Dias
    Camargo, Jessica Rocha
    de Castro, Bruna Santos
    Meireles, Lais Muniz
    Silva, Patricia Soares
    Janegitz, Bruno Campos
    Silva, Tiago Almeida
    BIOSENSORS-BASEL, 2023, 13 (04):
  • [26] Electrochemical acetylcholinesterase biosensor based on multi-walled carbon nanotubes/dicyclohexyl phthalate modified screen-printed electrode for detection of chlorpyrifos
    Chen, Dongfei
    Liu, Zengning
    Fu, Jiayun
    Guo, Yemin
    Sun, Xia
    Yang, Qingqing
    Wang, Xiangyou
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 801 : 185 - 191
  • [27] Screen-Printed Carbon Electrodes Modified with Polymeric Nanoparticle-Carbon Nanotube Composites for Enzymatic Biosensing
    Huang, Xuewen
    Xu, Sheng
    Zhao, Wei
    Xu, Mengyi
    Wei, Wei
    Luo, Jing
    Li, Xiaojie
    Liu, Xiaoya
    ACS APPLIED NANO MATERIALS, 2020, 3 (09) : 9158 - 9166
  • [28] MODIFIED SCREEN-PRINTED CARBON ELECTRODES WITH TYROSINASE FOR DETERMINATION OF PHENOLIC COMPOUNDS IN SMOKED FOOD
    Dragancea, V.
    Sturza, R.
    Boujtita, M.
    CHEMISTRY JOURNAL OF MOLDOVA, 2010, 5 (02): : 47 - 53
  • [29] Carbon nanotubes and graphene modified screen-printed carbon electrodes as sensitive sensors for the determination of phytochelatins in plants using liquid chromatography with amperometric detection
    Dago, Angela
    Navarro, Javier
    Arino, Cristina
    Manuel Diaz-Cruz, Jose
    Esteban, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1409 : 210 - 217
  • [30] Amperometric immunosensor for the determination of ceruloplasmin in human serum and urine based on covalent binding to carbon nanotubes-modified screen-printed electrodes
    Garcinuno, B.
    Ojeda, I.
    Moreno-Guzman, M.
    Gonzalez-Cortes, A.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    TALANTA, 2014, 118 : 61 - 67