QUALITY COMPARISON OF THE MANUAL CHEST COMPRESSION AND THE MECHANICAL CHEST COMPRESSION DURING DIFFICULT TRANSPORT CONDITIONS

被引:14
作者
Bekgoz, Burak [1 ]
San, Ishak [2 ]
Ergin, Mehmet [3 ]
机构
[1] Ankara City Hosp, Dept Emergency Med, Ankara, Turkey
[2] Univ Hlth Sci, Ankara City Hosp, Dept Emergency Med, Ankara, Turkey
[3] Yildirim Beyazit Univ, Fac Med, Dept Emergency Med, Ankara, Turkey
关键词
prehospital; resuscitation; chest compression; mechanical devices; CPR quality; HOSPITAL CARDIAC-ARREST; BASIC LIFE-SUPPORT; CARDIOPULMONARY-RESUSCITATION; CPR; DEFIBRILLATION; DEVICE; LUCAS;
D O I
10.1016/j.jemermed.2019.11.045
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Although there are several studies comparing the quality of manual and mechanical chest compressions, we decided to conduct this study because results of previous studies were not sufficient for us to arrive at a definite conclusion. Objective: In this study, our goal was to evaluate the quality of cardiopulmonary resuscitation (CPR) performed manually and by mechanical chest compression device (MCCD) when removing out-of- hospital cardiac arrest patients from their homes via stairs. Methods: A total of 20 paramedics participated in the study. The patient simulator manikin was moved down the stairs while each of 20 paramedics performed chest compressions, then it was moved down the stairs again 20 times while the MCCD performed chest compressions. Compression depth, compression rate, and hands-on times were recorded and the data were compared. Results: The median chest compression rate was 142.0 compressions/min (interquartile [25th to 75th percentile] range [IQR] 134.9-148.7 compressions/min) for the paramedics and 102.3 compressions/min for the MCCD (IQR 102.2-102.5 compressions/min) (p < 0.01). The median chest compression depth was 25.2 mm (IQR 23.2-30.9 mm) for the paramedics and 52.0 mm for the MCCD (IQR 51.4-52.6 mm) (p < 0.001). The rate of hands-on time for chest compressions performed by the paramedic participants was 92.0% (IQR 86.5-100%). Hands-on rate of the MCCD was 100% (p = 0.09). Conclusions: In our study, while carrying the patient simulator manikin to the lower floor, it was found that the MCCD achieved high-quality CPR targets recommended by resuscitation guidelines in terms of compression rate, depth, and hands-on-time. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:432 / 438
页数:7
相关论文
共 50 条
  • [1] Manual Chest Compression
    Saleem, Safwat
    Sonkin, Roman
    Sagy, Iftach
    Strugo, Refael
    Jaffe, Eli
    Drescher, Michael
    Shiber, Shachaf
    OPEN ACCESS EMERGENCY MEDICINE, 2022, 14 : 557 - 562
  • [2] Comparison of Manual vs. Mechanical Chest Compression Quality During Prehospital Cardiac Resuscitation
    Gaither, Joshua B.
    Rice, Amber D.
    Hu, Chengcheng
    Silver, Annemarie
    McDannold, Robyn
    Mullins, Margaret
    Spaite, Daniel W.
    Vadeboncoeur, Tyler F.
    George, Taylor A.
    Mullins, Terry
    Bobrow, Bentley J.
    CIRCULATION, 2017, 136
  • [3] Comparison of manual chest compression versus mechanical chest compression for out-of-hospital cardiac arrest: A systematic review and meta-analysis
    Larik, Muhammad Omar
    Ahmed, Ayesha
    Shiraz, Moeez Ibrahim
    Shiraz, Seemin Afshan
    Anjum, Muhammad Umair
    Bhattarai, Pratik
    MEDICINE, 2024, 103 (08) : E37294
  • [4] Transthoracic impedance for the monitoring of quality of manual chest compression during cardiopulmonary resuscitation
    Zhang, Hehua
    Yang, Zhengfei
    Huang, Zitong
    Chen, Bihua
    Zhang, Lei
    Li, Heng
    Wu, Baoming
    Yu, Tao
    Li, Yongqin
    RESUSCITATION, 2012, 83 (10) : 1281 - 1286
  • [5] Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR
    Park, Sang-Sub
    TECHNOLOGY AND HEALTH CARE, 2014, 22 (03) : 351 - 358
  • [6] Chest Compression Depth and Rate - Effect on Instructor Visual Assessment of Chest Compression Quality -
    Nagafuchi, Katsuya
    Hifumi, Toru
    Nishimoto, Naoki
    Kondo, Yutaka
    Yoshikawa, Kei
    Iwami, Taku
    Kuroda, Yasuhiro
    CIRCULATION JOURNAL, 2019, 83 (02) : 418 - +
  • [7] Mechanical chest-compression devices: current and future roles
    Perkins, Gavin D.
    Brace, Samantha
    Gates, Simon
    CURRENT OPINION IN CRITICAL CARE, 2010, 16 (03) : 203 - 210
  • [8] A Comparison of Chest Compression Quality Delivered During On-Scene and Ground Transport Cardiopulmonary Resuscitation
    Russi, Christopher S.
    Myers, Lucas A.
    Kolb, Logan J.
    Lohse, Christine M.
    Hess, Erik P.
    White, Roger D.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2016, 17 (05) : 634 - 639
  • [9] Complications of mechanical chest compression devices
    Platenkamp, M.
    Otterspoor, L. C.
    NETHERLANDS HEART JOURNAL, 2014, 22 (09) : 404 - 407
  • [10] Complications of mechanical chest compression devices
    M. Platenkamp
    L. C. Otterspoor
    Netherlands Heart Journal, 2014, 22 : 404 - 407