Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems

被引:209
作者
Branchini, Lauren [1 ,2 ]
Regatieri, Caio V. [1 ,3 ]
Flores-Moreno, Ignacio [4 ]
Baumann, Bernhard [1 ,5 ]
Fujimoto, James G. [5 ]
Duker, Jay S. [1 ]
机构
[1] Tufts Univ New England Med Ctr, Tufts Med Ctr, Boston, MA 02111 USA
[2] Boston Univ, Sch Med, Boston, MA 02118 USA
[3] Univ Fed Sao Paulo, Sao Paulo, Brazil
[4] Univ Hosp Albacete, Albacete, Spain
[5] MIT, Elect Res Lab, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
基金
美国国家卫生研究院;
关键词
CENTRAL SEROUS CHORIORETINOPATHY;
D O I
10.1016/j.ophtha.2011.07.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the reproducibility of choroidal thickness measurements in normal subjects on 3 spectral domain optical coherence tomography (SD-OCT) instruments: Zeiss Cirrus HD-OCT (Carl Zeiss Meditec Inc., Dublin, CA), Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany), and Optovue RTVue (Optovue Inc., Fremont, CA). Design: Cross-sectional non-interventional study. Participants: Images were obtained in 28 eyes of 28 healthy undilated volunteers without ocular pathology in a clinical setting. Methods: All subjects were imaged on the fovea using Cirrus HD 1-line raster, Spectralis enhanced depth imaging (EDI), and RTVue retina-cross. Main Outcome Measures: The choroid was measured subfoveally, 750 mu m temporal, and 750 mu m nasal to the fovea. All measurements were performed by 2 independent observers. Two-way analysis of variance (ANOVA) with Bonferroni's post-test, Pearson correlation, and Bland-Altman analysis were used to compare measurements. Results: The group of 28 subjects consisted of 7 men and 21 women, with an average age of 35.2 years (range, 23-64 years). A 2-way ANOVA with Bonferroni's post-test revealed no significant difference in the average subfoveal choroidal thickness (P > 0.05) among systems for any location: subfoveally, 750 mu m temporal, and 750 mu m nasal to the fovea. The measurements of choroidal thickness from any pair of 3 instruments (Cirrus vs. Spectralis, Cirrus vs. RTVue, Spectralis vs. RTVue) were also strongly correlated. The Pearson correlation among all 2 system pairs of the 3 systems was greater than 0.9 (P < 0.0001). The 95% limits of agreement among 4 choroidal thickness measurements were +11.21% to -13.57% (bias -1.17) between Cirrus and RTVue, +10.85% to -12.45% (bias -0.80) between Spectralis and RTVue, and +12.81% to -13.33% (bias -0.25) between Cirrus and Spectralis. Conclusions: In our population of young healthy adults with normal vision, there was good reproducibility among choroidal thickness measurements of images acquired with Cirrus, Spectralis, and RTVue. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2012; 119: 119-123 (C) 2012 by the American Academy of Ophthalmology.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 15 条
[1]   Enhanced Depth Imaging Optical Coherence Tomography of the Choroid in Highly Myopic Eyes [J].
Fujiwara, Takamitsu ;
Imamura, Yutaka ;
Margolis, Ron ;
Slakter, Jason S. ;
Spaide, Richard F. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (03) :445-450
[2]   Central serous chorioretinopathy: an update on pathogenesis and treatment [J].
Gemenetzi, M. ;
De Salvo, G. ;
Lotery, A. J. .
EYE, 2010, 24 (12) :1743-1756
[3]   ENHANCED DEPTH IMAGING OPTICAL COHERENCE TOMOGRAPHY OF THE CHOROID IN CENTRAL SEROUS CHORIORETINOPATHY [J].
Imamura, Yutaka ;
Fujiwara, Takamitsu ;
Margolis, Ron ;
Spaide, Richard F. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (10) :1469-1473
[4]  
Manjunath V, 2010, RETINA, V30, P1321
[5]   Choroidal Thickness in Normal Eyes Measured Using Cirrus HD Optical Coherence Tomography [J].
Manjunath, Varsha ;
Taha, Mohammad ;
Fujimoto, James G. ;
Duker, Jay S. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (03) :325-329
[6]  
Manjunath V, 2010, RETINA-J RET VIT DIS, V30, P1320, DOI 10.1097/IAE.0b013e3181e798b1
[7]   A Pilot Study of Enhanced Depth Imaging Optical Coherence Tomography of the Choroid in Normal Eyes [J].
Margolis, Ron ;
Spaide, Richard F. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (05) :811-815
[8]   SUBFOVEAL CHOROIDAL THICKNESS AFTER TREATMENT OF VOGT-KOYANAGI-HARADA DISEASE [J].
Maruko, Ichiro ;
Iida, Tomohiro ;
Sugano, Yukinori ;
Oyamada, Hiroshi ;
Sekiryu, Tetsuju ;
Fujiwara, Takamitsu ;
Spaide, Richard F. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (03) :510-517
[9]   Subfoveal Choroidal Thickness after Treatment of Central Serous Chorioretinopathy [J].
Maruko, Ichiro ;
Iida, Tomohiro ;
Sugano, Yukinori ;
Ojima, Akira ;
Ogasawara, Masashi ;
Spaide, Richard F. .
OPHTHALMOLOGY, 2010, 117 (09) :1792-1799
[10]   Macular Thickness Interoperator and Intraoperator Reproducibility in Healthy Eyes Using 7 Optical Coherence Tomography Instruments [J].
Pierro, Luisa ;
Giatsidis, Silvia M. ;
Mantovani, Elena ;
Gagliardi, Marco .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (02) :199-204