Non-Gaussian Diffusion Models and T1rho Quantification in the Assessment of Hepatic Sinusoidal Obstruction Syndrome in Rats

被引:4
作者
Lyu, Jian [1 ,2 ]
Yang, Guixiang [3 ,4 ]
Mei, Yingjie [5 ]
Guo, Li [1 ,2 ,6 ]
Guo, Yihao [1 ,2 ]
Zhang, Xinyuan [1 ,2 ]
Xu, Yikai [3 ,4 ]
Feng, Yanqiu [1 ,2 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, 1838 Guangzhou Ave N, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Guangdong, Peoples R China
[3] Southern Med Univ, Nanfang Hosp, Dept Med Imaging Ctr, Guangzhou, Guangdong, Peoples R China
[4] Southern Med Univ, Key Lab Mental Hlth, Minist Educ, Guangzhou, Guangdong, Peoples R China
[5] Philips Healthcare, Guangzhou, Guangdong, Peoples R China
[6] Sun Yat Sen Univ, Affiliated Foshan Hosp, Peoples Hosp Foshan 1, Dept MRI, Foshan, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
diffusion-weighted imaging; diffusion kurtosis imaging; stretched exponential; T(1)rho; hepatic sinusoidal obstruction syndrome; OXALIPLATIN-BASED CHEMOTHERAPY; COLORECTAL LIVER METASTASES; WATER DIFFUSION; MARROW-TRANSPLANTATION; VENOOCCLUSIVE DISEASE; OCCLUSIVE DISEASE; EUROPEAN-SOCIETY; FIBROSIS; HETEROGENEITY; COEFFICIENT;
D O I
10.1002/jmri.27156
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Non-Gaussian diffusion models and T(1)rho quantification may reflect the changes in tissue heterogeneity in hepatic sinusoidal obstruction syndrome (SOS). Purpose To investigate the feasibility of diffusion kurtosis imaging (DKI), stretched exponential model (SEM), and T(1)rho quantification in detecting and staging SOS in a monocrotaline (MCT)-induced rat model. Study Type Animal study. Population Thirty male Sprague-Dawley rats gavaged with MCT to induce hepatic SOS and six male rats without any intervention. Field Strength/Sequence 3.0T, DWI with five b-values (0-2000 s/mm(2)) and T(1)rho with five spin lock times (1-60 msec). Assessment MRI was performed 1 day before and 1, 3, 5, 7, and 10 days after MCT administration. The corrected apparent diffusion coefficient (D-app), kurtosis coefficient (K-app), distributed diffusion coefficient (DDC), and intravoxel water molecular diffusion heterogeneity (alpha) were calculated from the corresponding non-Gaussian diffusion model. The T(1)rho value was calculated using a monoexponential model. Specimens obtained from the six timepoints were categorized into normal liver (n = 6), early-stage (n = 16), and late-stage (n = 14) SOS in accordance with the pathological score. Statistical Tests Parametric statistical methods and receiver operating characteristic (ROC) curves were employed to determine diagnostic accuracy. Results The D-app, K-app, DDC, alpha, and T(1)rho values were correlated with pathological score with r values of -0.821, 0.726, -0.828, -0.739, and 0.714 (all P < 0.001), respectively. DKI (combined D-app and K-app) and SEM (combined DDC and alpha) were better than T(1)rho for staging SOS. The areas under the ROC curve of DKI, SEM, and T(1)rho for differentiating normal liver and early-stage SOS were 0.97, 1.00, and 0.79, whereas those of DKI, SEM, and T(1)rho for differentiating early-stage and late-stage SOS were 1.00, 0.97, and 0.92, respectively. Data Conclusion DKI, SEM, and T(1)rho may be helpful in staging SOS. Level of Evidence 2 Technical Efficacy Stage 2
引用
收藏
页码:1110 / 1121
页数:12
相关论文
共 40 条
[21]   Noninvasive assessment of hepatic sinusoidal obstructive syndrome using acoustic radiation force impulse elastography imaging: A proof-of-concept study in rat models [J].
Park, So Hyun ;
Lee, Seung Soo ;
Sung, Ji-Youn ;
Na, Kiyong ;
Kim, Hyoung Jung ;
Kim, So Yeon ;
Park, Beom Jin ;
Byun, Jae Ho .
EUROPEAN RADIOLOGY, 2018, 28 (05) :2096-2106
[22]   Body diffusion kurtosis imaging: Basic principles, applications, and considerations for clinical practice [J].
Rosenkrantz, Andrew B. ;
Padhani, Anwar R. ;
Chenevert, Thomas L. ;
Koh, Dow-Mu ;
De Keyzer, Frederik ;
Taouli, Bachir ;
Le Bihan, Denis .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (05) :1190-1202
[23]   Assessment of hepatocellular carcinoma using apparent diffusion coefficient and diffusion kurtosis indices: preliminary experience in fresh liver explants [J].
Rosenkrantz, Andrew B. ;
Sigmund, Eric E. ;
Winnick, Aaron ;
Niver, Benjamin E. ;
Spieler, Bradley ;
Morgan, Glyn R. ;
Hajdu, Cristina H. .
MAGNETIC RESONANCE IMAGING, 2012, 30 (10) :1534-1540
[24]   Severe hepatic sinusoidal obstruction associated with oxaliplatin-based chemotherapy in patients with metastatic colorectal cancer [J].
Rubbia-Brandt, L ;
Audard, V ;
Sartoretti, P ;
Roth, AD ;
Brezault, C ;
Le Charpentier, M ;
Dousset, B ;
Morel, P ;
Soubrane, O ;
Chaussade, S ;
Mentha, G ;
Terris, B .
ANNALS OF ONCOLOGY, 2004, 15 (03) :460-466
[25]   Sinusoidal Obstruction Syndrome [J].
Rubbia-Brandt, Laura .
CLINICS IN LIVER DISEASE, 2010, 14 (04) :651-+
[26]   Sinusoidal obstruction syndrome and nodular regenerative hyperplasia are frequent oxaliplatin-associated liver lesions and partially prevented by bevacizumab in patients with hepatic colorectal metastasis [J].
Rubbia-Brandt, Laura ;
Lauwers, Gregory Y. ;
Wang, Huamin ;
Majno, Pietro E. ;
Tanabe, Kenneth ;
Zhu, Andrew X. ;
Brezault, Catherine ;
Soubrane, Olivier ;
Abdalla, Eddie K. ;
Vauthey, Jean-Nicolas ;
Mentha, Gilles ;
Terris, Benoit .
HISTOPATHOLOGY, 2010, 56 (04) :430-439
[27]   SPIN LOCKING FOR MAGNETIC-RESONANCE IMAGING WITH APPLICATION TO HUMAN-BREAST [J].
SANTYR, GE ;
HENKELMAN, RM ;
BRONSKILL, MJ .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (01) :25-37
[28]   Liver fibrosis: stretched exponential model outperforms mono-exponential and bi-exponential models of diffusion-weighted MRI [J].
Seo, Nieun ;
Chung, Yong Eun ;
Park, Yung Nyun ;
Kim, Eunju ;
Hwang, Jinwoo ;
Kim, Myeong-Jin .
EUROPEAN RADIOLOGY, 2018, 28 (07) :2812-2822
[29]   Diffusion kurtosis imaging and diffusion-weighted imaging in assessment of liver fibrosis stage and necroinflammatory activity [J].
Sheng, Ruo Fan ;
Wang, He Qing ;
Yang, Li ;
Jin, Kai Pu ;
Xie, Yan Hong ;
Chen, Cai Zhong ;
Zeng, Meng Su .
ABDOMINAL RADIOLOGY, 2017, 42 (04) :1176-1182
[30]   Accuracy of gadoxetic acid-enhanced magnetic resonance imaging for the diagnosis of sinusoidal obstruction syndrome in patients with chemotherapy-treated colorectal liver metastases [J].
Shin, Na-Young ;
Kim, Myeong-Jin ;
Lim, Joon Seok ;
Park, Mi-Suk ;
Chung, Yong-Eun ;
Choi, Jin-Young ;
Kim, Ki Whang ;
Park, Young-Nyun .
EUROPEAN RADIOLOGY, 2012, 22 (04) :864-871