Liquid chromatography-electrochemistry-mass spectrometry of polycyclic aromatic hydrocarbons

被引:29
作者
van Leeuwen, SM
Hayen, H
Karst, U
机构
[1] Univ Twente, Dept Chem Anal, NL-7500 AE Enschede, Netherlands
[2] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
关键词
carcinogens; PAH; electrochemistry; LC-MS; on-line LC-electrochemistry-MS;
D O I
10.1007/s00216-003-2150-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An efficient method for fast elucidation of the electrochemical reactions of polycyclic aromatic hydrocarbons (PAH) has been set up by applying post-column electrochemistry in liquid chromatography-mass spectrometry (LC-MS). With this set-up strong improvement of sensitivity in the LC-MS analysis of PAH is observed. Due to their low redox potentials, the non-polar PAH are converted into the respective radical cations, which may further react with constituents of the mobile phase and in additional electrochemical oxidation steps. Among other products, mono-, di-, and trioxygenated species are observed in aqueous solutions, alkoxylated compounds in alcohols, and solvent adducts in the presence of acetonitrile. While more different products are observed by using atmospheric pressure chemical ionization in the positive-ion mode (APCI(+)), the deprotonation of hydroxylated species results in very clear spectra in the negative-ion mode (APCI(-)). Deuterated PAH and deuterated solvents were used to gain additional information on the formation of the reaction products.
引用
收藏
页码:917 / 925
页数:9
相关论文
共 27 条
[1]  
Bayer E, 1999, ANGEW CHEM INT EDIT, V38, P992, DOI 10.1002/(SICI)1521-3773(19990401)38:7<992::AID-ANIE992>3.0.CO
[2]  
2-K
[3]   Liquid chromatography with post-column electrochemical treatment and mass spectrometric detection of non-polar compounds [J].
Diehl, G ;
Liesener, A ;
Karst, U .
ANALYST, 2001, 126 (03) :288-290
[4]   On-line electrochemistry - MS and related techniques [J].
Diehl, G ;
Karst, U .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :390-398
[5]   A rapid and efficient mass spectrometric method for the analysis of explosives [J].
Evans, CS ;
Sleeman, R ;
Luke, J ;
Keely, BJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (19) :1883-1891
[6]   BIOMEDICAL AND BIOCHEMICAL APPLICATIONS OF LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
GELPI, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :59-80
[7]   LC-Electron capture APCI-MS for the determination of nitroaromatic compounds [J].
Hayen, H ;
Jachmann, N ;
Vogel, M ;
Karst, U .
ANALYST, 2002, 127 (08) :1027-1030
[8]  
JEFTIC L, 1970, J AM CHEM SOC, V92, P5282
[9]   Phenyl-modified reversed-phase liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry:: A universal method for the analysis of partially oxidized aromatic hydrocarbons [J].
Letzel, T ;
Pöschl, U ;
Wissiack, R ;
Rosenberg, E ;
Grasserbauer, M ;
Niessner, R .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1634-1645
[10]  
Letzel T, 1999, RAPID COMMUN MASS SP, V13, P2456, DOI 10.1002/(SICI)1097-0231(19991230)13:24<2456::AID-RCM812>3.0.CO