An instrument assessing satisfaction with iron chelation therapy: Psychometric testing from an open-label clinical trial

被引:9
作者
Rofail, Diana [1 ]
Viala, Muriel [2 ]
Gater, Adam [1 ]
Abetz-Webb, Linda [1 ]
Baladi, Jean-Francois [3 ]
Cappellini, Maria Domenica [4 ]
机构
[1] Mapi Values, Adelphi Mill, Bollington SK10 5JB, Cheshire, England
[2] Mapi Values, F-69003 Lyon, France
[3] Novartis Pharmaceut, E Hanover, NJ USA
[4] Univ Milan, Policlin Fdn IRCCS, Milan, Italy
关键词
iron overload; satisfaction; instrument; oral iron chelation therapy; QUALITY-OF-LIFE; BETA-THALASSEMIA; ECONOMIC BURDEN; DEFEROXAMINE; CONVERGENT; DEFICIENCY; OVERLOAD; FERRITIN; SERUM; CARE;
D O I
10.1007/s12325-010-0049-y
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The Satisfaction with Iron Chelation Therapy (SICT) instrument was developed based on a literature review, in-depth patient and clinician interviews, and cognitive debriefing interviews. An, open-label, single arm, multicenter trial evaluating the efficacy and safety of deferasirox in patients diagnosed with transfusion-dependent iron overload, provided an opportunity to assess the psychometric measurement properties of the instrument. Psychometric analyses were performed using data at baseline from 273 patients with a range of transfusion-dependent iron overload conditions who were participating in a multinational study. Responsiveness was further evaluated for all patients who also had subsequent satisfaction domain scores collected at week 4. Baseline SICT domain scores had acceptable floor and ceiling effects and internal consistency reliability (Cronbach's alpha: 0.75-0.85). Item discriminant and item convergent validity were both excellent although one item in each analysis did not meet the specified criterion. Small to moderate correlations were observed between SICT and Short Form 36 Health Survey (SF-36) domain scores. Patients with the highest levels of serum ferritin at baseline (> 3100 ng/mL) were the least satisfied about the Perceived Effectiveness of ICT and vice versa. Satisfaction improved in all patients, although there were no clear differences observed between groups of patients defined according to changes in serum ferritin levels from baseline to week 4 (stable, improved, or worsened). The SICT domains are reliable and valid. Further testing using a more specific criterion (such as assessing patient global ratings of change in satisfaction domains that correspond to the SICT domains) could help to establish with greater confidence the responsiveness of the instrument.
引用
收藏
页码:533 / 546
页数:14
相关论文
共 37 条
[1]   The impact of iron overload and its treatment on quality of life: results from a literature review [J].
Abetz, Linda ;
Baladi, Jean-Francois ;
Jones, Paula ;
Rofail, Diana .
HEALTH AND QUALITY OF LIFE OUTCOMES, 2006, 4 (1)
[2]   IMMUNORADIOMETRIC ASSAY FOR FERRITIN IN SERUM OF NORMAL SUBJECTS AND PATIENTS WITH IRON-DEFICIENCY AND IRON OVERLOAD [J].
ADDISON, GM ;
BEAMISH, MR ;
JACOBS, A ;
HALES, CN ;
HODGKINS, M ;
LLEWELLIN, P .
JOURNAL OF CLINICAL PATHOLOGY, 1972, 25 (04) :326-+
[3]   Effectiveness and safety of combined iron-chelation therapy with deferoxamine and deferiprone [J].
Alymara, V ;
Bourantas, D ;
Chaidos, A ;
Bouranta, P ;
Gouva, M ;
Vassou, A ;
Tzouvara, E ;
Bourantas, KL .
HEMATOLOGY JOURNAL, 2004, 5 (06) :475-479
[4]  
[Anonymous], 1999, The handbook of psychological testing
[5]   'It would be good to know you're not alone': The health care needs of women with menstrual symptoms [J].
Byles, JE ;
Hanrahan, PF ;
Schofield, MJ .
FAMILY PRACTICE, 1997, 14 (03) :249-254
[6]   CONVERGENT AND DISCRIMINANT VALIDATION BY THE MULTITRAIT-MULTIMETHOD MATRIX [J].
CAMPBELL, DT ;
FISKE, DW .
PSYCHOLOGICAL BULLETIN, 1959, 56 (02) :81-105
[7]  
CAPPELLINI MD, 2006, US ONCOL DIS, P67
[8]  
Cattell R.B., 1973, PERSONALITY MOOD QUE
[9]  
Cohen J., 1988, Statistical power analysis for the behavioral sciences, VSecond
[10]  
Cronbach LJ, 1951, PSYCHOMETRIKA, V16, P297