ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY OF THE LIVER IN HEALTHY PATIENTS: TEST LOCATION, REFERENCE RANGE AND INFLUENCE OF GENDER AND BODY MASS INDEX

被引:23
作者
Liao, Li-Ying [1 ]
Kuo, Kuan-Liang [2 ]
Chiang, Huei-Shin [1 ]
Lin, Chong-Zong [1 ]
Lin, Yi-Ping [3 ]
Lin, Chih-Lin [1 ]
机构
[1] Taipei City Hosp, Dept Gastroenterol, Renai Branch, Ctr Liver, Taipei, Taiwan
[2] Taipei City Hosp, Dept Family Med, Renai Branch, Taipei, Taiwan
[3] Taipei City Hosp, Inst Clin Res & Training, Taipei Databank Publ Hlth Anal, Taipei, Taiwan
关键词
Acoustic radiation force impulse; Liver fibrosis; Elastography; Shear wave; Reference range; Gender Age; Body mass index; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; NONINVASIVE EVALUATION; ARFI ELASTOGRAPHY; FIBROSIS; STIFFNESS; DISEASE; QUANTIFICATION; DIAGNOSIS; ACCURACY;
D O I
10.1016/j.ultrasmedbio.2014.09.030
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective of this study was to evaluate the best test location and study factors associated with acoustic radiation force impulse (ARFI) elastography measurements in healthy individuals. When ARFI elastography was performed on 68 healthy patients after controlling for all known test condition factors except segmental location, the median shear wave velocities (SWVs) derived from five valid measurements in the area between S5 and S8 in patients in the supine position had a significantly lower mean and the narrowest 95% confidence interval, followed by those for the S8 supine and S8 semidecubitus locations (p = 0.045). Analysis of mean SWVs revealed similar, although statistically insignificant, findings (p = 0.078). Male patients had significantly higher median SWVs (p = 0.0073) and mean SWVs (p = 0.0043) than female patients. Patients with body mass indexes>22 had significantly lower median SWVs (p = 0.0033) and mean SWVs (p = 0.0008) than those with body mass indexes <= 22. S5/8 supine was the better test location for ARFI. The reference ranges for median and mean SWV were 0.81-1.27 and 0.82-1.27 m/s, respectively. Gender and body mass index, but not age, were the significant factors associated with ARFI SWV values. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:698 / 704
页数:7
相关论文
共 26 条
[1]   FACTORS WHICH INFLUENCE THE ACCURACY OF ACOUSTIC RADIATION FORCE IMPULSE (ARFI) ELASTOGRAPHY FOR THE DIAGNOSIS OF LIVER FIBROSIS IN PATIENTS WITH CHRONIC HEPATITIS C [J].
Bota, Simona ;
Sporea, Ioan ;
Sirli, Roxana ;
Popescu, Alina ;
Jurchis, Ana .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (03) :407-412
[2]   Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis [J].
Boursier, Jerome ;
Isselin, Gael ;
Fouchard-Hubert, Isabelle ;
Oberti, Frederic ;
Dib, Nina ;
Lebigot, Jerome ;
Bertrais, Sandrine ;
Gallois, Yves ;
Cales, Paul ;
Aube, Christophe .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2010, 22 (09) :1074-1084
[3]   Effects of patient factors on noninvasive liver stiffness measurement using acoustic radiation force impulse elastography in patients with chronic hepatitis C [J].
Chen, Sheng-Hung ;
Li, Yu-Fen ;
Lai, Hsueh-Chou ;
Kao, Jung-Ta ;
Peng, Cheng-Yuan ;
Chuang, Po-Heng ;
Su, Wen-Pang ;
Chiang, I-Ping .
BMC GASTROENTEROLOGY, 2012, 12
[4]   ARFI, FibroScan®, ELF, and their combinations in the assessment of liver fibrosis: A prospective study [J].
Crespo, Gonzalo ;
Fernandez-Varo, Guillermo ;
Marino, Zoe ;
Casals, Gregori ;
Miquel, Rosa ;
Martinez, Stella M. ;
Gilabert, Rosa ;
Forns, Xavier ;
Jimenez, Wladimiro ;
Navasa, Miquel .
JOURNAL OF HEPATOLOGY, 2012, 57 (02) :281-287
[5]   Acoustic radiation force impulse of the liver [J].
D'Onofrio, Mirko ;
Crosara, Stefano ;
De Robertis, Riccardo ;
Canestrini, Stefano ;
Demozzi, Emanuele ;
Gallotti, Anna ;
Mucelli, Roberto Pozzi .
WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (30) :4841-4849
[6]   Accuracy of Real-Time Shear Wave Elastography for Assessing Liver Fibrosis in Chronic Hepatitis C: A Pilot Study [J].
Ferraioli, Giovanna ;
Tinelli, Carmine ;
Dal Bello, Barbara ;
Zicchetti, Mabel ;
Filice, Gaetano ;
Filice, Carlo .
HEPATOLOGY, 2012, 56 (06) :2125-2133
[7]   Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis [J].
Fierbinteanu-Braticevici, Carmen ;
Andronescu, Dan ;
Usvat, Radu ;
Cretoiu, Dragos ;
Baicus, Cristian ;
Marinoschi, Gabriela .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (44) :5525-5532
[8]   Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography [J].
Friedrich-Rust, Mireen ;
Wunder, Katrin ;
Kriener, Susanne ;
Sotoudeh, Fariba ;
Richter, Swantje ;
Bojunga, Joerg ;
Herrmann, Eva ;
Poynard, Thierry ;
Dietrich, Christoph F. ;
Vermehren, Johannes ;
Zeuzem, Stefan ;
Sarrazin, Christoph .
RADIOLOGY, 2009, 252 (02) :595-604
[9]   Impact of Food Intake, Ultrasound Transducer, Breathing Maneuvers and Body Position on Acoustic Radiation Force Impulse (ARFI) Elastometry of the Liver [J].
Goertz, R. S. ;
Egger, C. ;
Neurath, M. F. ;
Strobel, D. .
ULTRASCHALL IN DER MEDIZIN, 2012, 33 (04) :380-385
[10]   Acoustic radiation force impulse quantification: repeatability of measurements in selected liver segments and influence of age, body mass index and liver capsule-to-box distance [J].
Jaffer, O. S. ;
Lung, P. F. C. ;
Bosanac, D. ;
Patel, V. M. ;
Ryan, S. M. ;
Heneghan, M. A. ;
Quaglia, A. ;
Sidhu, P. S. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018) :E858-E863