Mechanical prevention of distal embolization during primary angioplasty - Safety, feasibility, and impact on myocardial reperfusion

被引:115
作者
Limbruno, U
Micheli, A
De Carlo, M
Amoroso, G
Rossini, R
Palagi, C
Di Bello, V
Petronio, AS
Fontanini, G
Mariani, M
机构
[1] Univ Pisa, Cardiac & Thorac Dept, Pisa, Italy
[2] Univ Pisa, Dept Oncol Transplants & New Technol Med, Pisa, Italy
关键词
myocardial infarction; angioplasty; embolism; reperfusion;
D O I
10.1161/01.CIR.0000079223.47421.78
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Effective myocardial reperfusion after primary percutaneous coronary intervention (PCI) may be limited by distal embolization. We tested the safety, feasibility, and efficacy of the FilterWire-Ex (FW), a distal embolic protection device, as an adjunct to primary PCI. Methods and Results-Fifty-three consecutive patients undergoing primary PCI with FW protection were compared with a matched control group treated by primary PCI alone. Successful FW positioning was obtained in 47 patients (89%) without complications. Histological analysis of the content of the last 13 filters showed multiple embolic debris in all cases. FW use was associated with lower postinterventional corrected TIMI frame count (22 +/- 14 versus 31 +/- 19; P=0.005) and higher occurrence of grade 3 myocardial blush (66% versus 36%; P=0.006) and early ST-segment elevation resolution (80% versus 54%; P=0.006). At multivariate analysis, FW use was the only independent predictor of early ST-segment elevation resolution and of grade 3 myocardial blush. FW patients showed lower peak creatine kinase-MB release (236 +/- 172 versus 333 +/- 219 ng/mL; P=0.013) and greater improvement at 30 days in left ventricular wall motion score index (-0.30 +/- 0.19 versus -0.18 +/- 0.26; P=0.008) and ejection fraction (+7 +/- 4% versus +4 +/- 7%; P=0.012). Conclusions-FW use during primary PCI is feasible and safe. Distal embolization prevention appears to exert a beneficial effect on markers of myocardial reperfusion and on left ventricular function improvement at 30 days.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 29 条
  • [1] Relation of phasic coronary flow velocity characteristics with TIMI perfusion grade and myocardial recovery after primary percutaneous transluminal coronary angioplasty and rescue stenting
    Akasaka, T
    Yoshida, K
    Kawamoto, T
    Kaji, S
    Ueda, Y
    Yamamuro, A
    Takagi, T
    Hozumi, T
    [J]. CIRCULATION, 2000, 101 (20) : 2361 - 2367
  • [2] Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
    Baim, DS
    Wahr, D
    George, B
    Leon, MB
    Greenberg, J
    Cutlip, DE
    Kaya, U
    Popma, JJ
    Ho, KKL
    Kuntz, RE
    [J]. CIRCULATION, 2002, 105 (11) : 1285 - 1290
  • [3] Belli G, 2000, CATHETER CARDIO INTE, V50, P362, DOI 10.1002/1522-726X(200007)50:3<362::AID-CCD22>3.0.CO
  • [4] 2-H
  • [5] Intracoronary thrombectomy with the X-sizer catheter system improves epicardial flow and accelerates ST-segment resolution in patients with acute coronary syndrome - A prospective, randomized, controlled study
    Beran, G
    Lang, I
    Schreiber, W
    Denk, S
    Stefenelli, T
    Syeda, B
    Maurer, G
    Glogar, D
    Siostrzonek, P
    [J]. CIRCULATION, 2002, 105 (20) : 2355 - 2360
  • [6] Prevention of distal embolization during saphenous vein graft lesion angioplasty - Experience with a new temporary occlusion and aspiration system
    Carlino, M
    De Gregorio, J
    Di Mario, C
    Anzuini, A
    Airoldi, F
    Albiero, R
    Briguori, C
    Dharmadhikari, A
    Sheiban, I
    Colombo, A
    [J]. CIRCULATION, 1999, 99 (25) : 3221 - 3223
  • [7] Determinants and prognostic implications of persistent ST-segment elevation after primary angioplasty for acute myocardial infarction - Importance of microvascular reperfusion injury on clinical outcome
    Claeys, MJ
    Bosmans, J
    Veenstra, L
    Jorens, P
    De Raedt, H
    Vrints, CJ
    [J]. CIRCULATION, 1999, 99 (15) : 1972 - 1977
  • [8] The coronary no-reflow phenomenon: a review of mechanisms and therapies
    Eeckhout, E
    Kern, MJ
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 (09) : 729 - 739
  • [9] TIMI frame count: A quantitative method of assessing coronary artery flow
    Gibson, CM
    Cannon, CP
    Daley, WL
    Dodge, JT
    Alexander, B
    Marble, SJ
    McCabe, CH
    Raymond, L
    Fortin, T
    Poole, WK
    Braunwald, E
    [J]. CIRCULATION, 1996, 93 (05) : 879 - 888
  • [10] Synergy between intracoronary stenting and abciximab improving angiographic and clinical outcomes of primary angioplasty in acute myocardial infarction
    Giri, S
    Mitchel, JF
    Hirst, JA
    McKay, RG
    Azar, RR
    Mennett, R
    Waters, DD
    Kiernan, FJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (03) : 269 - 274