Year-long continuous personal exposure to PM2.5 recorded by a fast responding portable nephelometer

被引:21
作者
Branis, Martin [1 ]
Kolomaznikova, Jana [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Inst Environm Studies, Prague 12843 2, Czech Republic
关键词
Air pollution; Particulate matter; Personal exposure; Microenvironment; Time-activity diary; FINE PARTICULATE MATTER; FIXED-SITE; SUSPENDED PARTICULATE; TEMPORAL VARIABILITY; AMBIENT MEASUREMENTS; MASS CONCENTRATIONS; EUROPEAN EXPOLIS; AEROSOL MONITORS; NITROGEN-DIOXIDE; INDOOR AEROSOLS;
D O I
10.1016/j.atmosenv.2010.04.050
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Personal exposure to particulate matter of aerodynamic diameter under 2.5 mu m (PM2.5) was monitored using a DustTrak nephelometer. The battery-operated unit, worn by an adult individual for a period of approximately one year, logged integrated average PM2.5 concentrations over 5 min intervals. A detailed time-activity diary was used to record the experimental subject's movement and the microenvironments visited. Altogether 239 days covering all the months (except April) were available for the analysis. In total, 60 463 acceptable 5-min averages were obtained. The dataset was divided into 7 indoor and 4 outdoor microenvironments. Of the total time, 84% was spent indoors, 10.9% outdoors and 5.1% in transport. The indoor 5-min PM2.5 average was higher (55.7 mu g m(-3)) than the outdoor value (49.8 mu g m(-3)). The highest 5-min PM2.5 average concentration was detected in restaurant microenvironments (1103 mu g m(-3)), the second highest 5-min average concentration was recorded in indoor spaces heated by stoves burning solid fuels (420 mu g m(-3)). The lowest 5-min mean aerosol concentrations were detected outdoors in rural/natural environments (25 mu g m(-3)) and indoors at the monitored person's home (36 mu g m(-3)). Outdoor and indoor concentrations of PM2.5 measured by the nephelometer at home and during movement in the vicinity of the experimental subject's home were compared with those of the nearest fixed-site monitor of the national air quality monitoring network. The high correlation coefficient (0.78) between the personal and fixed-site monitor aerosol concentrations suggested that fixed-site monitor data can be used as proxies for personal exposure in residential and some other microenvironments. Collocated measurements with a reference method (beta-attenuation) showed a non-linear systematic bias of the light-scattering method, limiting the use of direct concentration readings for exact exposure analysis. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2865 / 2872
页数:8
相关论文
共 43 条
[1]   Spatial and temporal variability in outdoor, indoor, and personal PM2.5 exposure [J].
Adgate, JL ;
Ramachandran, G ;
Pratt, GC ;
Waller, LA ;
Sexton, K .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (20) :3255-3265
[2]   Total personal exposure to fine particulate matter in an urban adult population:: the role of ambient air and transport [J].
Boudet, C ;
Dechénaux, J ;
Balducci, F ;
Masclet, P ;
Zmirou, D .
INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 1998, 20 (1-4) :30-38
[3]   Can one use ambient air concentration data to estimate personal and population exposures to particles? An approach within the European EXPOLIS study [J].
Boudet, C ;
Zmirou, D ;
Vestri, V .
SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 267 (1-3) :141-150
[4]   The contribution of ambient sources to particulate pollution in spaces and trains of the Prague underground transport system [J].
Branis, M .
ATMOSPHERIC ENVIRONMENT, 2006, 40 (02) :348-356
[5]  
BRAUER M, 1995, J EXPO ANAL ENV EPID, V5, P45
[6]   Ambient site, home outdoor and home indoor particulate concentrations as proxies of personal exposures [J].
Brown, Kathleen Ward ;
Sarnat, Jeremy A. ;
Suh, Helen H. ;
Coull, Brent A. ;
Spengler, John D. ;
Koutrakis, Petros .
JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (09) :1041-1051
[7]   Exposure level of carbon monoxide and respirable suspended particulate in public transportation modes while commuting in urban, area of Guangzhou, China [J].
Chan, LY ;
Lau, WL ;
Zou, SC ;
Cao, ZX ;
Lai, SC .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (38) :5831-5840
[8]   Laboratory and field evaluation of measurement methods for one-hour exposures to O3, PM2.5, and CO [J].
Chang, LT ;
Suh, HH ;
Wolfson, JM ;
Misra, K ;
Allen, GA ;
Catalano, PJ ;
Koutrakis, P .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (10) :1414-1422
[9]   Comparison of real-time instruments used to monitor airborne particulate matter [J].
Chung, A ;
Chang, DPY ;
Kleeman, MJ ;
Perry, KD ;
Cahill, TA ;
Dutcher, D ;
McDougall, EM ;
Stroud, K .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (01) :109-120
[10]   Characterization of fine particulate matter in Ohio: Indoor, outdoor, and personal exposures [J].
Crist, Kevin C. ;
Liu, Bian ;
Kim, Myoungwoo ;
Deshpande, Seemantim R. ;
John, Kuruvilla .
ENVIRONMENTAL RESEARCH, 2008, 106 (01) :62-71