Simultaneous Electrochemical Sensing of Ceftriaxone and Piroxicam Using Zeolite Modified Electrode for Medical Applications

被引:15
作者
Khosravi-Hamoleh, Amir [1 ]
Abrishamkar, Maryam [1 ]
Cheraghizade, Mohsen [2 ]
机构
[1] Islamic Azad Univ, Ahvaz Branch, Dept Chem, Ahvaz, Iran
[2] Islamic Azad Univ, Ahvaz Branch, Dept Elect Engn, Ahvaz, Iran
关键词
Simultaneous electrochemical sensing; Ceftriaxone; Piroxicam; Zeolite meso-structures; Medical applications; MODIFIED CARBON-PASTE; NANOMOLAR SIMULTANEOUS DETECTION; REDUCED GRAPHENE OXIDE; VOLTAMMETRIC DETERMINATION; GLASSY-CARBON; SENSOR; NANOPARTICLES; EPINEPHRINE; NANOTUBES; ACID;
D O I
10.1002/elan.202100121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous sensing of Ceftriaxone (Cef) and Piroxicam (Pir) was presented in detail through the electrochemical method in which carbon paste electrode (CPE) was modified by meso-structured Zeolite for medical application. The results indicated a polycrystalline Zeolite phase with a relatively high surface contact for charge transportation in the sensing process. Electrochemical impedance spectroscopy (EIS) plots also showed better charge transportation parameters for the modified electrode. The effect of analytes concentration, in both individual and simultaneous states, on the electrochemical sensor quality parameters was investigated by different methods and the obtained results were thoroughly discussed.
引用
收藏
页码:1866 / 1870
页数:5
相关论文
共 29 条
[21]   Consistency of photoelectrochemistry and photoelectrochemical microwave reflection demonstrated with p- and n-type layered semiconductors like MoS2 [J].
Moehl, Thomas ;
Kunst, Marinus ;
Wuensch, Frank ;
Tributsch, Helmut .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 609 (01) :31-41
[22]   Enhanced ethanol gas-sensing performance of Pb-doped In2O3 nanostructures prepared by sonochemical method [J].
Montazeri, Asieh ;
Jamali-Sheini, Farid .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 :778-791
[23]   ELECTROCHEMICAL REDUCTION OF CEPHALOSPORANIC ACIDS [J].
OCHIAI, M ;
AKI, O ;
MORIMOTO, A ;
OKADA, T ;
SHINOZAK.K ;
ASAHI, Y .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 1, 1974, (02) :258-262
[24]   Electrochemical oxidation of ranitidine at poly(dopamine) modified carbon paste electrode: Its voltammetric determination in pharmaceutical and biological samples based on the enhancement effect of anionic surfactant [J].
Pinar, P. Talay ;
Yardim, Y. ;
Senturk, Z. .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 :1463-1473
[25]   Fabrication of an electrochemical sensor based on the electrodeposition of Pt nanoparticles on multiwalled carbon nanotubes film for voltammetric determination of ceftriaxone in the presence of lidocaine, assisted by factorial-based response-surface methodology [J].
Shahrokhian, Saeed ;
Hosseini-Nassab, Niloufar ;
Kamalzadeh, Zahra .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (01) :77-88
[26]  
Sweetman SC, 2009, MARTINDALE COMPLETE, V3709
[27]   Drug detection in breath: non-invasive assessment of illicit or pharmaceutical drugs [J].
Trefz, Phillip ;
Kamysek, Svend ;
Fuchs, Patricia ;
Sukul, Pritam ;
Schubert, Jochen K. ;
Miekisch, Wolfram .
JOURNAL OF BREATH RESEARCH, 2017, 11 (02)
[28]   Determination of piroxicam and nimesulide using an electrochemical sensor based on reduced graphene oxide and PEDOT:PSS [J].
Wong, Ademar ;
Santos, Anderson Martin ;
Fatibello-Filho, Orlando .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 :547-555
[29]   Advances in rapid drug detection technology [J].
Zou, Wen-Bo ;
Yin, Li-Hui ;
Jin, Shao-Hong .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 147 :81-88